Models HG2 and HG4 

Fountain Installation Instructions

  

Thrifty King fountains are intended to be energy free, however, a number of factors must be met for this to be the 

case: 

 

There must be at least 10-12 animals that have the Thrifty King fountain as their only source of water. 

 

There must be a good seal against wind between the concrete platform and base of the unit. 

 

The supply water temperature must be at least 42

o

F. (This may be an issue for rural or municipal water 

supplies.) 

 

Ritchie Thermal Tubes are recommended. 

If these factors are not met, supplemental heat is recommended. Please see Supplemental Heat section of 

this manual, page 3 for specific recommendations. 

A.

 

Location

 - Putting the fountain 

in a location that offers protection 

from the wind will enhance the 

performance of the fountain. 

Livestock will tend to gather in this 

protected area, enticing them to 

drink more. If possible, the side that 

supply line enters the fountain 

should be opposite of prevailing 

winter wind to give additional 

protection to the supply line. 

B.

 

Water Supply Line – 

The horizontal underground water line (#1) should be sized to account for pressure 

drop, relating to distance, at least 3/4” (1” recommended) in diameter and 1’ below normal frost depth. A 3/4” (1” 

recommended) vertical supply pipe (#2) is recommended. A shut-off valve (#3) may be installed under the 

fountain for easier servicing. For optimum serviceability a stop and waste valve can be installed below frost level 

to drain water back when unit is not in use. Flush water supply line thoroughly before connecting to fountain. 

Water supplies with foreign material such as sand, rust, etc. may require a filter to keep valve working properly. 

C.

 

Riser Tube

 – Install a riser tube (#4) around pipe to provide room for 

plumbing and to accommodate optional shut-off valve. Ensure that the water 

supply line is centered in the riser tube. Do not add any insulation in the riser tube, 

as it provides a path for frost. For optimum water line protection, use the insulated 

Ritchie Thermal Tube. Use whatever combination of Thermal Tubes is required to 

reach at least 1' below frost line.  

 

Ritchie Thermal Tube 

Part # 

Description 

18158 

1’ Top Section 

16417 

2’ Top Section 

16612 

4’ Top Section 

16416 2’ 

Extension 

1”

Thrifty King Swine Instruction Manual

1

17 April, 2014

Содержание Thrifty King for Swine HG 2

Страница 1: ...he finest watering fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructi...

Страница 2: ...ater Supply Line The horizontal underground water line 1 should be sized to account for pressure drop relating to distance at least 3 4 1 recommended in diameter and 1 below normal frost depth A 3 4 1...

Страница 3: ...outside edge of the fountain Use additional foam weather stripping provided to create a seal between the outside edge of the riser tube and access opening on the bottom of the fountain G Hold Downs Th...

Страница 4: ...Serial number or date code is found on underneath side of top red valve cover This information will be needed for warranty Ritchie Valves Ritchie valves come in three pressure ratings as shown The Th...

Страница 5: ...5 20 x Hex Head Screw 10 Pkg 1 Pkg 6 11515 Valve Bracket Pkg 1 Pkg 17 16577 Foamed Base 1 7 16266 Lifting Lid TKHG W Guard 2 NS 15930 3 8 Hose Clamp Pkg SS 1 Pkg 8 18066 10 24x HexHeadScrewSS 6 Pkg 1...

Страница 6: ...Hex Head Screw 10 Pkg 1 Pkg 6 11515 Valve Bracket Pkg 1 Pkg 17 16579 Foamed HG4 Base 1 7 16266 Lifting Lid TKHG W Guard 4 NS 15930 3 8 Hose Clamp Pkg SS 1 Pkg 8 18066 10 24x HexHeadScrewSS 6 Pkg 1 Pk...

Страница 7: ...Defective part s will be repaired or replaced at the option of Ritchie Industries This warranty specifically excludes all labor and shipping charges This warranty does not apply to any appearance ite...

Отзывы: