Models HG2 and HG4
Fountain Installation Instructions
Thrifty King fountains are intended to be energy free, however, a number of factors must be met for this to be the
case:
There must be at least 10-12 animals that have the Thrifty King fountain as their only source of water.
There must be a good seal against wind between the concrete platform and base of the unit.
The supply water temperature must be at least 42
o
F. (This may be an issue for rural or municipal water
supplies.)
Ritchie Thermal Tubes are recommended.
If these factors are not met, supplemental heat is recommended. Please see Supplemental Heat section of
this manual, page 3 for specific recommendations.
A.
Location
- Putting the fountain
in a location that offers protection
from the wind will enhance the
performance of the fountain.
Livestock will tend to gather in this
protected area, enticing them to
drink more. If possible, the side that
supply line enters the fountain
should be opposite of prevailing
winter wind to give additional
protection to the supply line.
B.
Water Supply Line –
The horizontal underground water line (#1) should be sized to account for pressure
drop, relating to distance, at least 3/4” (1” recommended) in diameter and 1’ below normal frost depth. A 3/4” (1”
recommended) vertical supply pipe (#2) is recommended. A shut-off valve (#3) may be installed under the
fountain for easier servicing. For optimum serviceability a stop and waste valve can be installed below frost level
to drain water back when unit is not in use. Flush water supply line thoroughly before connecting to fountain.
Water supplies with foreign material such as sand, rust, etc. may require a filter to keep valve working properly.
C.
Riser Tube
– Install a riser tube (#4) around pipe to provide room for
plumbing and to accommodate optional shut-off valve. Ensure that the water
supply line is centered in the riser tube. Do not add any insulation in the riser tube,
as it provides a path for frost. For optimum water line protection, use the insulated
Ritchie Thermal Tube. Use whatever combination of Thermal Tubes is required to
reach at least 1' below frost line.
Ritchie Thermal Tube
Part #
Description
18158
1’ Top Section
16417
2’ Top Section
16612
4’ Top Section
16416 2’
Extension
1”
Thrifty King Swine Instruction Manual
1
17 April, 2014