are provided. Screw the hold down angles on to the unit as needed, then anchor down the unit. Use of 3/8” x 3-
1/2” stainless steel expansion anchor bolts (not included) is recommended for concrete installations. Anchor bolts
are available from Ritchie in a two pack, part # 14261. Use an all-weather sealant under the outside edge when
anchoring to concrete to keep air from leaking under fountain.
F.
Hose Connection
- Connect hose fitting to shut-off valve at top of concrete. Slip on barb fitting with
furnished clamps. Hose should not touch insulation or outside surface of fountain. Place the hose under the
fountain as you move the unit in place over the riser tube.
G.
Electrical Connection
-
The electrical installation should be made and maintained by a qualified
electrician conforming to national and local codes.
The 3-wire power to the fountain must be protected by a
suitable fuse or circuit breaker with properly sized wire. For wiring connections, see wiring diagram. Wire nuts
may be used for the 120-volt and neutral splices.
NOTE:
National/Local electrical codes may require livestock waterers installed in feedlots in open
feeding area to be grounded by a separate stranded copper grounding conductor or at least no.6 AWG
terminating at a point where the branch circuit receives its supply. Check with local inspection
authorities.