Risen SYP200S Скачать руководство пользователя страница 5

 
 
Please contact   your local dealer   with Questions regarding    mounting profiles for modules. 
 

 

 

 

 

 

 

 

 

 

 

 

Please  check  appearance  of  the  modules before installing or using. 

Notes on Installation

 

Clearance between the module frame    and the mounting surface is required   to allow  cooling  air  to  circulate  around 

the back of the module. This also allows any condensation or moisture to dissipate. 

The module should never be sealed to the mounting surface with sealant that prevents air from circulating under the 

module.For roof-mounted  modules,the  minimum Distance between the roof and the modules should be 5cm (2 

inch).This module has 8 elliptical hole for installation ,with dimension 9*14mm,4 on each longer side. For installation 

safety ,we recommend that the minimum torque of screw between 5~8N.m. 

We recommend installation  methods shown in below.In some areas, local electrical and building  codes  may govern 

the installation and use of PV modules. 

Please noted all washers,nut and bolt are stainless steel. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание SYP200S

Страница 1: ...this manual is elieved to be reliable but does not constitute an expressed and implied warranty RISEN reserves the right to make changes to the product specifications or manual without prior notice Ge...

Страница 2: ...solar cell modules To avoid the hazard of electric shock and injury be sure to ground the modules completely To avoid the hazard of fire and injury do not disassemble the module or remove any part in...

Страница 3: ...Never leave a module unsupported or unsecured Do not drop module and do not allow objects to fall on module to avoid the hazard of injury or any troubles in modules that it may cause Do not use or in...

Страница 4: ...e Additional devices such as ground fault fuses and disconnects may be required Do not use modules of different configurations in the same system Follow all safety precautions of other used components...

Страница 5: ...ever be sealed to the mounting surface with sealant that prevents air from circulating under the module For roof mounted modules the minimum Distance between the roof and the modules should be 5cm 2 i...

Страница 6: ...heavy at installation place 4 The sand and dust damages are heavy at installation place 5 Other special conditions with air pollution or with chemically active vapor etc SPECIFICATIONS Notes on speci...

Страница 7: ...6PCS 48PCS 72PCS 88PCS Dimens ion mm 1200 550 3 5mm 1080 80 8 35mm 1580 808 35mm 1456 1070 50 mm Note Module complies with the requirements of Electrical protection Class II Rated electrical character...

Страница 8: ...uirements or the IEC Note stainless steel washers are used between the ground wire and the module frame see picture 2 The size of grounding hole is 4mm The screw is 5 0mm All washers are with inter di...

Страница 9: ...ox has a diagram illustrating the proper direction for the by pass diode to be installed between two of the terminal screws When the solar modules are connected as individual series strings first and...

Страница 10: ...NINGHAI RISEN ELECTRIC CO LTD Add Xidian Shaojia Lndustrial Zone Ninghai Ninbo Zhejiang 315613 China Tel 0086 574 65173958 Fax 0086 574 65173959 Website http www risen solar com...