background image

FORCE

 - 13

1 - Place the 4 side elements vertically as in the image alongside.

2 - Using the round head screws provided, assemble the hexagonal structure. 
It is very important to assemble the 4 elements vertically and on a surface 
that ensures excellent flatness so as to obtain a reliable support surface 
for the closing flange. 

Attention: The screw head must be placed on the 

internal side of the foundation case.

 See figure alongside.

3 - Before fixing the upper flange, insert the metallic protection of the 50 
mm diameter corrugated pipe which must be set in the ground to make 
the  subsequent  electrical  connection  with  the  control  unit.  See  figures 
alongside.

GB

Assembly instructions - FORCE 825/I

Содержание FORCE 825/I

Страница 1: ...n Manual de instalación I Dissuasore di sosta e passaggio Brevettato Patented Made in Italy RL8542007 Rev 04 GB Parking and passage rising bollard D Poller gegen unrechtmäßiges Parken und Durchfahren F Borne escamotable anti stationnement et anti accès E Disuasor de tránsito de aparcamiento y de paso ...

Страница 2: ...that the product FORCE 825 I complies in all its components with Directives EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC as per checks carried out by ECO Certificazioni S p A via Mengolina 33 48018 Faenza RA Marano Vicentino 30 11 10 The legal representative GB Declaration of conformity 340x340 254 800 305 1237 1 2m 3 5 8 3 3 5 55 1306 3 5 8 GB Overall Dimensions ...

Страница 3: ...ate in sequence and with a high visibility reflecting band The bollard can be easily unlocked in an emergency In the event of a power cut different functions can be selected the bollard can remain in raised position or can be unlocked and lowered by keeping the emergency button pressed automatic lowering in the event of a power cut is also available accessory The system can also be fitted with an ...

Страница 4: ...flatness so as to obtain a reliable support surface for the closing flange Attention The screw head must be placed on the internal side of the foundation case See figure alongside 3 Before fixing the upper flange insert the metallic protection of the 50 mm diameter corrugated pipe which must be set in the ground to make the subsequent electrical connection with the control unit See figures alongsi...

Страница 5: ... the corrugated sheath must be 200mm from the flooring surface as shown in figure Insert the 50 mm diameter corrugated sheath in the case using the metal guide The corrugated pipe must enter a maximum of 2 3 cm inside of the metal protection so that it does not interfere when the bollard is later inserted Fix the case with cement Attention Make sure during the cast that the fixing plug located un ...

Страница 6: ... to keep the path as straight as possible avoiding sharp corners See figures alongside S S S 10 Attention The bollard is equipped with a short segment of con nection cable equipped with a male IP68 connector Different size extension cords are available 5 to 25 m equipped with a female IP68 connector for connecting to the control unit Bring the two parts of the connector together aligning the arrow...

Страница 7: ...o be connected by a sheath with a diameter of 50 mm correctly placed without joints or cross section re ductions The cable must be gradually released while the bollard descends in the case Ref B Once the insertion has been completed the connector must be in proximity of the metal protection ref C Pay attention to the electrical cable it must be free inside the case housing and it must not be crush...

Страница 8: ...to reduce possible infiltrations if the flooring allows it plan on a slight slope around the foundation case See figures alongside 13 After positioning the bollard inside the case remove the lifting eye bolts and using the same holes position the blocks on the pipe guide ring The blocks are necessary in order to lift the bollard without the treadable flange Insert the M10x40 TCEI stainless steel s...

Страница 9: ...686039 2 Cylinder cover R9686020 3 Control unit R9686003 4 24Vdc motor with encoder and electronic brake R9686029 5 Treadable flange R9686021 6 Flange gasket O ring R9686022 7 Mechanical stop collar R9686030 8 Mobile cylinder R9686031 8b Inox jacket 825I R9686037 9 Actuator R9686032 10 Fixed cylinder R9686033 11 Connection cable with IP68 connector R9686013 FORCE 825I ...

Отзывы: