54
ProSYS Installation and Programming Manual
11
22
28
28
IMQ Install
NO
YES/NO
YES:
Causes the following parameters to function as follows:
Auto Arm Bypass:
If there is an open zone during the Auto Arm process,
the system will be armed, and an alarm will be sounded (unless the
open zone is closed).
Guard User:
If a Guard user disarms a partition, the system will be armed
automatically after the predefined time period (refer to
Guard
, page
49). If there is an open zone during the arming process, the system
will be armed, and an alarm will be sounded (unless the open zone is
closed).
NO:
Causes the following parameters to function as follows:
Auto Arm Bypass:
If the Auto Arm programming arms the system and
there is an open zone during the auto arm, the system will bypass the
open zones and arm the system.
Guard User:
If a Guard user disarms a partition, the system will be armed
automatically after the predefined time period (refer to
Guard
, page
49). If there is an open zone during the arming process, the partition
will be bypassed.
11
22
29
29
Grand Master
Authority/Partition
YES
YES/NO
YES:
Specifies that the allowed partitions and the authority level of a user can
be changed by the Installer (Installer menu) or the Grand Master (User menu).
NO:
Specifies that only the Installer can change the partition and the authority
level of a user from the Installer programming menu.
11
22
30
30
Double Code
NO
YES/NO
Requires two User Codes or proximity cards to be entered in order to disarm
the system, which provides a higher level of security. In addition, only the
common partitions between the two users will be disarmed.
YES:
To disarm the system, two users must enter their codes or pass their
proximity cards one after the other. The time between entering the two User
Codes is 60 seconds. If the second code is entered after 60 seconds, 3 error
beeps will be sounded.
NO:
Enables any user, with the appropriate authority, to disarm the system
using only one User Code or proximity card.
NOTES:
When using the
Double Code
feature, there will not be a restriction in operating
with one user through the Electronic Key or Access Control module.
The
Maid
,
Arm Only
,
UO Only
, and
Guard
authority levels cannot be used to
perform double code disarming.