EVENT MESSAGE
DESCRIPTION
NXT HOM:P=X
Partition X is armed in Next Stay mode
OPEN DOOR=XX
Door XX opened
OVERLOAD
PS=X
Overload from 3A SMPS X
OVERLOAD RS
PS=X
Overload restore from 3A SMPS X
PHONE FAIL
If the phone line is cut or the DC level is under 3V
PHONE
RESTORE
Phone line trouble restore
PIR RSTR Z=XXX
PIR trouble restore from BUS zone XXX
PIR TRBL Z=XXX
PIR trouble from BUS zone XXX
POLICE KP=XX
Police alarm from keypad (ID=XX) (keys 1 & 2)
POLICE WB=XX
Panic button on keyfob XX was pressed
POT.LOAD RS
PS=X
Potential overload restore of 3A SMPS joined by 3A SMPS X
POT.OVRLOAD
PS=X
Potential overload of SMPS joined by 3A SMPS X
PRN=X FUL RS
Printer module X buffer is down to less than 75% of its capacity
PRN=X FULL
Printer module X buffer is full to more than 75% of its capacity
PROX FAIL S=X
Fail in the proximity anti approach protection in siren X
PROX OK
SIREN=X
Proximity anti approach protection is restored in siren X
PROX TMP RS
S=X
Proximity tamper restore from siren ID =X
PROX TMP
SIREN=X
Proximity tamper from approaching siren ID=X
PS=X OVER.R
C=YY
Overload in 3A SMPS X. Reset by user YY
READER=XX
SET
Set reader XX criteria
REMOTE PROG
The system has been programmed from the UD software
RESTORE
Z=XXX
Alarm restore in zone XXX
RMT ARM:P=X
Partition X armed from the UD software
RMT DIS:P=X
Partition X disarmed from the UD software
RMT HOM:P=X
Partition X armed in Stay mode from the UD software
SELF FAIL
Z=XXX
BUS zone XXX has failed the Self Test
SELF OK Z=XXX
Self Test in BUS zone XXX has been restored