ProSYS Installation and Programming Manual
157
Accessories: Add Delete Module
Quick Keys
Parameter
Default
Range
FZ08 (an 8 Hardwired Zone Expander with FAST and extended
loop response definitions)
BZ08 ( Virtual 8 Zone Expander)
BZ16 (Virtual 16 Zone Expander)
G3Z08 (an 8 Hardwired Zone Expander with TEOL termination)
G3Z16 (a 16 Hardwired Zone Expander with TEOL termination)
BZE08 (8 BUS zone expander)
BZE16 (16 BUS zone expander)
BZ24 (24 BUS zone expander)
BZ32 (32 BUS zone expander)
4. Press
/
to confirm (and store) your choice.
5. Repeat the process for other Zone Expanders in the system (up to 8,
depending on your installed model).
6. Press
to return to the previous programming level.
If a Zone Expander is found and
NONE
has been selected, the following
display appears:
7. To return to the previous display, press
/
,
-OR-
Press the
/
key to select
[Y] YES
and press
/
to confirm the delete.
77
11
33
Utility Output Module
U008
1. Press [3]. The following display appears:
2. Use
the
/
or
/
keys to position the cursor over
the ID number to be assigned (or deleted) for this Utility Output. The first
UO must be assigned to the first ID number, which is
1
.
NOTE:
Check that the UO's physical ID number has been "dip switch" programmed, as
described in
Chapter 3, Installing External Modules and Devices.