background image

  

 

 |   

Rinnai Smart Cylinders low-medium pressure indoor stainless steel: Owner and installer guide: 20432-A 01-15

Safety messages

•  Element cover

 

Do not remove the 

element cover, this will 

expose 230 V wiring, it 

must only be removed by 

an authorised person.  

•  Damaged components

 

If any component is 

damaged, it must be 

replaced by an authorised 

person using Rinnai 

replacement parts. 

•  Child supervision

 

Children should be 

supervised to ensure they 

do not play with any part 

of the hot water system. 

•  Hot pipe work

 

Care should be taken not 

to touch the pipe work 

from the cylinder as this 

could be very hot.

Safety devices

Your cylinder should have 

the following safety devices 

fitted.

V

alVe

 

Vented

 

systems

 

- pressure reducing valve 

- pressure relief valve 

- cold water expansion valve 

- tempering valve 

- energy cutout thermostat 

O

pen

 

vented

 

systems

 

- pressure reducing valve 

- tempering valve 

- energy cut-out thermostat 

- vent pipe 

Do not operate the system 

unless all the safety devices 

are fitted and are in working 

order. It is also important that 

you do not tamper or remove 

any of these devices.

Your hot water system has an 

energy cutout thermostat. 

The operation of this thermal 

cut-out indicates a dangerous 

situation. Do not reset the 

thermal cutout until the 

cylinder has been serviced by 

an authorised person.

Draining and filling the 

system

This normally occurs during 

installation or servicing and 

must be carried out by an 

authorised person.

Installation by a licensed 

tradesperson

Only a licensed tradesperson 

can install, adjust, maintain, 

and service this water heater. 

Any work carried out by a  

non-licensed tradesperson 

is illegal and will void any 

warranty.

Turning the cylinder on/off 

(we don't recommend this)

If you switch the 

cylinder off for more 

than 18 hours it will 

lose all the water usage 

history.

LIMITED

WARRANTY*

10

Important

All cylinders have the potential to leak water. To minimise damage to 

other areas of your home, ensure that your cylinder has been installed 

with a drip tray—the person doing the installation is responsible for this.

* Refer to the warranty terms and conditions in this guide for more information.

IMPORTANT

Содержание Smart Cylinders

Страница 1: ...steel Owner and installer guide Models Rinnai Smart Cylinders Low medium pressure duplex stainless steel LS13555030S LS18055030S LS25055030S Hello installer Please leave this guide with the home owne...

Страница 2: ...maintenance can cause property damage personal injury or loss of life The appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of expe...

Страница 3: ...lation Specification summary 12 Dimensions 13 Plumbing setup 14 Storage and delivery temperatures 15 Water quality 16 Electrical supply and connections 17 Valves and fittings 18 Commissioning 18 Limit...

Страница 4: ...will automatically adjust the cylinder heating times according to your hot water usage pattern A certain amount of hot water is guaranteed at all times depending on the level you select Manual mode P...

Страница 5: ...ter temp in cylinder 1 50 C 2 55 C 3 60 C 4 65 C 5 70 C Biosafe operation To meet the New Zealand Building Code requirement1 to disinfect water for legionella bacteria2 the system will perform heating...

Страница 6: ...e fitted and are in working order It is also important that you do not tamper or remove any of these devices Your hot water system has an energy cutout thermostat The operation of this thermal cut out...

Страница 7: ...hard water areas the element s must be periodically descaled To do this the unit must be drained and the element s removed Rinnai has a maintenance service and spare parts network with personnel who a...

Страница 8: ...same time for more than three seconds I have cold water while in iQ automatic mode A sudden significant increase of hot water consumption may generate occasional cold water Change to manual mode and...

Страница 9: ...small quantity of water through the drain line If water is discharging continuously there may be a fault with one of the valves contact the installer to discuss Water is too hot If possible check the...

Страница 10: ...This page intentionally left blank...

Страница 11: ...Installation Installation servicing and repair shall be carried out only by authorised personnel...

Страница 12: ...r also needs to be oriented so that the control is in a position where the homeowner can easily see and access it Operating pressures Maximum inlet pressure 120 kPa Maximum working pressure 120 kPa El...

Страница 13: ...d inlet eco solar Top view Element Side cold inlet bottom cold inlet top outlet all sizes 45 45 Dimensions Tank size A mm B mm C mm Height mm Diam mm 135 L 320 N A 335 1015 550 180 L 320 465 335 1295...

Страница 14: ...l of our Stainless Steel cylinders are super light At under 55kg each one burly plumber can transport carry and install them easy Show us your muscles www youtube com RinnaiNZ I www facebook com rinna...

Страница 15: ...pipe work should be insulated with polythene foam or equivalent insulation to optimise performance and energy efficiency To prevent damage to the water heater when attaching pipe clips or saddles to t...

Страница 16: ...ality and filtration experts be undertaken Hard water Hard water containing calcium carbonate can cause scaling on hot surfaces We recommend a water temperature of no more than 65 C to minimise scale...

Страница 17: ...er must be capable of withstanding the appliance load Fixed wiring must be protected from contact with the internal hot surface of the water heater Electrical access is via a hole in the element cover...

Страница 18: ...ach tap when the water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Switch on the electric power supply To turn off the water heater It may be neces...

Страница 19: ...rranty period Warranty All components Up to 1 year Replace or repair free of charge the cylinder and or part if it fails due to faulty manufacture Inner cylinder Years 2 5 inclusive Replace or repair...

Страница 20: ...anufacturer s instructions 4 The warranty applies only to the components supplied by Rinnai It does not apply to components supplied by others such as but not limited to these isolating valves electri...

Страница 21: ...Rinnai 5 Where the cylinder has failed directly or indirectly as a result of poor water quality outside the limits specified 6 Where it is found that there is no fault with the cylinder and the issue...

Страница 22: ...inner cylinder and causes damage to carpets and flooring 11 months Yes No Cost of cylinder replacement covered by Rinnai Consequential loss damage to carpets and flooring is not1 Inner cylinder fails...

Страница 23: ...01 15 23 Please keep these details in a safe place for future reference ATTACH YOUR PROOF OF PURCHASE HERE RECORD YOUR details OF PURCHASE BELOW Retailer Retailer address Date of purchase Product deta...

Страница 24: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz 20432 A...

Отзывы: