Rinnai Smart Cylinders low-medium pressure indoor stainless steel: Owner and installer guide: 20432-A 01-15   |   15

Base requirements

Tanks should be installed on a flat level base of sufficient strength to support the weight of the 

water heater when full. 

The water heater must also be suitably restrained against seismic activity, ‘G12/AS1 Figure 14’ 

details an acceptable method of restraint.

Drip tray/catch pan (MUST be fitted)

The Rinnai warranty does not cover any consequential loss from leaks to the cylinder, so it’s 

important a suitably drained drip tray/catch pan is fitted.

Position of control

Make sure the control is in a position that is easily seen and accessible for the homeowner.

Pipe work

It is the installer’s responsibility to adequately size the distribution pipe work in a property to 

ensure sufficient performance from all outlet fittings. Water pipe sizing should be performed 

in accordance with AS/NZS 3500.4 and/or G12 AS1. Pipe sizing and valve selection must be 

performed to allow for the water supply pressure. 

A drain off tap or line must be fitted to the inlet of the water heater.

All hot water pipe work should be insulated with polythene foam or equivalent insulation to 

optimise performance and energy efficiency.

To prevent damage to the water heater when attaching pipe clips or saddles to the jacket, it is 

recommended that self drilling screws with a maximum length of 12 mm are used. If drilling is 

required take extreme care not to penetrate the inner cylinder.

Storage and delivery temperatures

Storage temperature: Biosafe operation

To meet the New Zealand Building Code requirement

1

 to disinfect water for legionella bacteria, 

the system will perform heating above 60 °C whenever risk conditions (<60 °C for 21 days) are 
detected.

The access cover to the element and thermostat must only be removed by an electrician 

or other suitably qualified tradesperson.

 
Sanitary fixtures delivery temperature
Water temperatures over 55 

°

C can cause severe scalds. Local regulations must be considered 

regarding temperature limitations of hot water supplied to areas used primarily for personal 

hygiene. The temperature is limited to 45 

°

C for early childhood centres, schools, nursing 

homes or similar facilities and 55 

°

C for all other buildings. To comply with these requirements, a 

temperature limiting device, such as a tempering or thermostatic mixing valve will be required 

on all installations.

WARNING

1

 Clause G12.3.9

Содержание Smart Cylinders

Страница 1: ...steel Owner and installer guide Models Rinnai Smart Cylinders Low medium pressure duplex stainless steel LS13555030S LS18055030S LS25055030S Hello installer Please leave this guide with the home owne...

Страница 2: ...maintenance can cause property damage personal injury or loss of life The appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of expe...

Страница 3: ...lation Specification summary 12 Dimensions 13 Plumbing setup 14 Storage and delivery temperatures 15 Water quality 16 Electrical supply and connections 17 Valves and fittings 18 Commissioning 18 Limit...

Страница 4: ...will automatically adjust the cylinder heating times according to your hot water usage pattern A certain amount of hot water is guaranteed at all times depending on the level you select Manual mode P...

Страница 5: ...ter temp in cylinder 1 50 C 2 55 C 3 60 C 4 65 C 5 70 C Biosafe operation To meet the New Zealand Building Code requirement1 to disinfect water for legionella bacteria2 the system will perform heating...

Страница 6: ...e fitted and are in working order It is also important that you do not tamper or remove any of these devices Your hot water system has an energy cutout thermostat The operation of this thermal cut out...

Страница 7: ...hard water areas the element s must be periodically descaled To do this the unit must be drained and the element s removed Rinnai has a maintenance service and spare parts network with personnel who a...

Страница 8: ...same time for more than three seconds I have cold water while in iQ automatic mode A sudden significant increase of hot water consumption may generate occasional cold water Change to manual mode and...

Страница 9: ...small quantity of water through the drain line If water is discharging continuously there may be a fault with one of the valves contact the installer to discuss Water is too hot If possible check the...

Страница 10: ...This page intentionally left blank...

Страница 11: ...Installation Installation servicing and repair shall be carried out only by authorised personnel...

Страница 12: ...r also needs to be oriented so that the control is in a position where the homeowner can easily see and access it Operating pressures Maximum inlet pressure 120 kPa Maximum working pressure 120 kPa El...

Страница 13: ...d inlet eco solar Top view Element Side cold inlet bottom cold inlet top outlet all sizes 45 45 Dimensions Tank size A mm B mm C mm Height mm Diam mm 135 L 320 N A 335 1015 550 180 L 320 465 335 1295...

Страница 14: ...l of our Stainless Steel cylinders are super light At under 55kg each one burly plumber can transport carry and install them easy Show us your muscles www youtube com RinnaiNZ I www facebook com rinna...

Страница 15: ...pipe work should be insulated with polythene foam or equivalent insulation to optimise performance and energy efficiency To prevent damage to the water heater when attaching pipe clips or saddles to t...

Страница 16: ...ality and filtration experts be undertaken Hard water Hard water containing calcium carbonate can cause scaling on hot surfaces We recommend a water temperature of no more than 65 C to minimise scale...

Страница 17: ...er must be capable of withstanding the appliance load Fixed wiring must be protected from contact with the internal hot surface of the water heater Electrical access is via a hole in the element cover...

Страница 18: ...ach tap when the water runs freely without air bubbles 4 Check all plumbing connections and pipe work for water leaks 5 Switch on the electric power supply To turn off the water heater It may be neces...

Страница 19: ...rranty period Warranty All components Up to 1 year Replace or repair free of charge the cylinder and or part if it fails due to faulty manufacture Inner cylinder Years 2 5 inclusive Replace or repair...

Страница 20: ...anufacturer s instructions 4 The warranty applies only to the components supplied by Rinnai It does not apply to components supplied by others such as but not limited to these isolating valves electri...

Страница 21: ...Rinnai 5 Where the cylinder has failed directly or indirectly as a result of poor water quality outside the limits specified 6 Where it is found that there is no fault with the cylinder and the issue...

Страница 22: ...inner cylinder and causes damage to carpets and flooring 11 months Yes No Cost of cylinder replacement covered by Rinnai Consequential loss damage to carpets and flooring is not1 Inner cylinder fails...

Страница 23: ...01 15 23 Please keep these details in a safe place for future reference ATTACH YOUR PROOF OF PURCHASE HERE RECORD YOUR details OF PURCHASE BELOW Retailer Retailer address Date of purchase Product deta...

Страница 24: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz 20432 A...

Отзывы: