![Rinnai RU180iN Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/rinnai/ru180in/ru180in_installation-and-operation-manual_1463143006.webp)
6
V53De Manual
Ref
Description
Canadian Installations
(CSA B149.1)
US Installations
(ANSI Z223.1 / NFPA 54)
A
Clearance above grade, veranda, porch, deck, or balcony
12 inches (30 cm)
12 inches (30 cm)
B
Clearance to window or door that may be opened
6 in (15 cm) for appliances
≤ 10,000
Btuh (3
kW), 12 in (30 cm) for appliances > 10,000
Btuh (3 kW) and
≤ 100,000
Btuh (30 kW), 36 in
(91 cm) for appliances >100,000 Btuh (30 kW)
4 ft (1.2 m) below or to side of opening;
1 ft (300 mm) above opening
C
Clearance to permanently closed window
*
*
D
Vertical clearance to ventilated soffit, located above the terminal within a
horizontal distance of 2 feet (61 cm) from the center line of the terminal
*
*
E
Clearance to unventilated soffit
*
*
F
Clearance to outside corner
*
*
G
Clearance to inside corner
*
*
H
Clearance to each side of center line extended above meter/regulator
assembly
*
*
I
Clearance to service regulator vent outlet
Above a regulator within 3 ft (91 cm)
horizontally of the vertical center line of the
regulator vent outlet to a maximum vertical
distance of 15 ft (4.5 m)
*
J
Clearance to non
-
mechanical air supply inlet to building or the combustion
air inlet to any other appliance
6 in (15 cm) for appliances
≤ 10,000
Btuh (3
kW), 12 in (30 cm) for appliances > 10,000
Btuh (3 kW) and
≤ 100,000
Btuh (30 kW), 36 in
(91 cm) for appliances >100,000 Btuh (30 kW)
4 ft (1.2 m) below or to side of opening;
1 ft (300 mm) above opening
K
Clearance to a mechanical air supply inlet
6 ft (1.83 m)
3 ft (91 cm) above if within 10 ft (3 m)
horizontally
L
Clearance above paved sidewalk or paved driveway located on public
property
7 ft (2.13 m)
7 ft (2.13 m)
M
Clearance under veranda, porch, deck, or balcony
12 inches (30 cm)
‡
*
* For clearances not specified in ANSI Z223.1/NFPA 54 or CSA B149.1, one of the following shall be indicated:
A) a minimum clearance value determined by testing in accordance with Clause 5.21, Draft hoods; or
B) a reference to the following footnote:
“
Clearance in accordance with local installation codes and the requirements of the gas supplier.
”
†
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
‡
Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.
Notes:
1)
In accordance with the current CSA B149.1,
Natural Gas and Propane Installation Code
.
2)
In accordance with the current ANSI Z223.1/NFPA 54,
National Fuel Gas Code
.
Exhaust Outlet Clearances
AIR SUPPLY INLET
VENT TERMINAL
AREA WHERE TERMINAL
IS NOT PERMITTTED
X
V
SNOW
TERMINATION
Clearance in
Ref. A also
applies to
anticipated
snow line