Rinnai RU180iN Скачать руководство пользователя страница 33

 

 

V53De Manual

 

33

 

Limited Warranty

   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What is Covered?

 

The Rinnai Standard Limited Warranty covers any defects in materials or workmanship when the product is 

 

installed and operated according to Rinnai written installation instructions, subject to the terms within this 

 

Limited Warranty document. This Limited Warranty applies only to products that are installed correctly in the 
United States and Canada. Improper installation may void this Limited Warranty. It is recommended that a 
trained and qualified professional who has attended a Rinnai installation training class complete your 

 

installation. This Limited Warranty coverage, as set out in the table below, extends to the original purchaser and 
subsequent owners, but only while the product remains at the site of the original installation, and terminates if 
the product is moved or reinstalled at a new location.

 

Item 

 

Period of Coverage (from date of purchase)

 

Residential 

Applications 

 

If installed with a tankless 

isolation valve kit for 

residential applications

 

If used for both residential 

water heating and space 

heating purposes

 

Heat Exchanger

 

10 years 

[1]

 

12 years 

[1]

 

10 years 

[2]

 

All Other Parts and 

Components

 

5 years 

[1]

 

5 years 

[1]

 

5 years 

[2]

 

Reasonable Labor

 

1 year 

 

1 year

 

1 year

 

[1]

 

The warranty period is reduced to 3 years from date of purchase when the water heater is used as a circulating water heater 

within a hot water circulation loop, where the water heater is in series with a circulation system and all circulating water flows 
through the water heater, and where an on

-

demand recirculation system is not incorporated. 

 

On

-

demand recirculation is defined as a hot water recirculating loop or system that utilizes existing hot and cold lines or a 

dedicated return line, and only activates when hot water is used. It can be activated by a push button, motion sensor, or voice 
activation but not by a temperature sensor. A timer added to a standard recirculating pump is not considered as on

-

demand.

 

[2]

 

The air handler pump must be sized for the flow rate of the heat load, pressure losses through the air handler coil, pressure 

losses though the Rinnai tankless water heater, and piping and components connecting the air handler and tankless unit. Refer 
to the tankless water heater pressure loss curve and consult with the air 

 

handler/component manufacturer for pressure loss information. 

 

What Will Rinnai Do?

 

Rinnai will repair or replace the covered product or any part or component that is defective in materials or 

 

workmanship as set forth in the above table. Rinnai will pay reasonable labor charges associated with the repair 
or replacement of any such part or component during the term of the labor warranty period. All repair parts 
must be genuine Rinnai parts. All repairs or replacements must be performed by a qualified professional who is 
properly trained to do the type of repair.

 

Replacement of the product may only be authorized by Rinnai at its sole discretion. Rinnai does not authorize 
any person or company to assume for it any obligation or liability in connection with the replacement of the 
product. If Rinnai determines that repair of a product is not possible, Rinnai may replace the product with a 

 

comparable product at Rinnai

s sole discretion. The warranty claim for product parts and labor may be denied if 

a component or product returned to Rinnai is found to be free of defects in material or workmanship; damaged 
by improper installation, use or operation; or damaged during return shipping.

 

How to Obtain Service

 

For the name of a trained and qualified professional, please contact your place of purchase, visit the Rinnai 

 

website (www.rinnai.us), call Rinnai at 1

-

800

-

621

-

9419

 

or write to Rinnai at 103 International Drive, Peachtree 

City, Georgia 30269.

 

Содержание RU180iN

Страница 1: ...manual must be left for the consumer The consumer must read and refer to this manual for proper operation and to maintain the water heater If the information in these instructions is not followed exa...

Страница 2: ...Electricity 13 Installation of Temperature Controller 14 Mounting the Controller 15 Final Checklist 16 Technical Data 17 Specifications 17 Dimensions 18 Pressure Drop and Water Flow Curves 19 Ladder...

Страница 3: ...diately below the water heater or by turning off the water supply to the building WARNING AVERTISSEMENT Use only your hand to push in or turn the gas control knob Never use tools If the knob will not...

Страница 4: ...d water This appliance is suitable for filling large or whirlpool spa tubs with potable water Do not use substitute parts that are not authorized for this appliance MUST DO The installation must confo...

Страница 5: ...onment water quality and need for freeze protection Requirements for the gas line water lines electrical connection and Should overheating occur or the gas supply fail to shut off turn off the manual...

Страница 6: ...30 cm for appliances 10 000 Btuh 3 kW and 100 000 Btuh 30 kW 36 in 91 cm for appliances 100 000 Btuh 30 kW 4 ft 1 2 m below or to side of opening 1 ft 300 mm above opening K Clearance to a mechanical...

Страница 7: ...that are found in aerosol sprays detergents bleaches cleaning solvents oil based paints varnishes and refrigerants The air in beauty shops dry cleaning stores photo processing labs and storage areas f...

Страница 8: ...Mobile Homes Leave the entire manual taped to the temperature controller if installed or give the entire manual directly to the consumer Mount to Wall 1 Identify the installation location and confirm...

Страница 9: ...Z21 22 and or the standard Temperature Pressure Temperature and Pressure Relief Valves and Vacuum Relief Valves CAN1 4 4 The relief valve must be rated up to 150 psi and to at least the maximum BTU h...

Страница 10: ...ump Solenoid Valve Boiler Drain Valve KEY This is not an engineered drawing It is intended only as a guide and not as a replacement for professionally engineered project drawings This drawing is not i...

Страница 11: ...rmance Installation of Gas Supply MUST DO A manual gas control valve must be placed in the gas supply line to the water heater A union can be used on the connection above the shut off valve for the fu...

Страница 12: ...the 3 4 inch pipe size is capable of supplying 188 FT3 HR of natural gas Gas Input of all gas products BTU HR Heating Value of Gas BTU FT 3 Cubic Feet per Hour CFH Any compound used on the threaded jo...

Страница 13: ...klist for Gas and Electricity A manual gas control valve is placed in the gas line to the water heater Check the gas lines and connections for leaks Confirm that the gas inlet pressure is within limit...

Страница 14: ...Controllers Maximum Cable Length for each Controller to Water Heater 1 328 ft 100 m 2 164 ft 50 m 3 or 4 65 ft 20 m Turn the power off Do not attempt to connect the temperature controllers with the p...

Страница 15: ...using the holes drilled in step 2 7 Disconnect power from the water heater 8 Remove the screw on the Quick Cable Connector Fig 1 9 Rotate the Quick Cable Connector Fig 2 10 Route the wires through th...

Страница 16: ...t pressure is within limits Confirm that the water heater is rated for the gas type supplied Confirm that the electricity is supplied from a 120 VAC 60 Hz power source is in a properly grounded circui...

Страница 17: ...more information 140 F 60 C Minimum Temperature Setting 115 F 46 C Weight 29 7 lb 13 5 kg Noise level 54 dB Electrical Consumption Normal 50W Standby 2 W Anti frost Protection 64W Max Current 1 2A Fu...

Страница 18: ...ot Water Outlet from wall 3 4 87 F Hot Water Outlet from center 4 1 105 G Cold Water Inlet from wall 2 7 68 H Cold Water Inlet from center 0 4 10 I Gas Connection from wall 3 0 77 J Gas Connection fro...

Страница 19: ...V53De Manual 19 Pressure Drop Curve Water Flow Curve 0 0 1 0 2 0 3 0 4 0 5 0 6 0 0 25 50 75 100 125 150 delta T Temperature Rise F Pressure Loss ft head Water Flow gpm Water Flow gpm Pressure Loss psi...

Страница 20: ...20 V53De Manual Ladder Diagram...

Страница 21: ...product s you registered and or you account with us Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Leave...

Страница 22: ...eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau TO TURN OFF GAS TO APPLIANC...

Страница 23: ...art of the control system and any gas control which has been under water N utilisez pas cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi...

Страница 24: ...water sources are able to provide water at this temperature setting until it is changed again at this or another temperature controller DANGER Hot water can be dangerous especially for infants or chi...

Страница 25: ...cked by pressing the Priority button and the up button together for 5 seconds A beep will sound confirming that the controller is locked The display will alternately show LOC the temperature setting a...

Страница 26: ...Push Button 3 PB3 White MENU button cycles through available menus 1 2 3 4 5 and 6 see table below 4 Push Button 4 PB4 White VALUE button cycles through available menu values see table below 5 Push B...

Страница 27: ...and or regulator is sized properly Ensure gas type and pressure is correct Bleed all air from gas lines Ensure condensation collar was installed properly Verify dip switches and programming parameter...

Страница 28: ...istance of motor winding 70 PC Board Replace the PC Board 71 Solenoid Valve Circuit Replace the PC Board 72 Flame Sensing Device Verify flame rod is touching flame when unit fires Check all wiring to...

Страница 29: ...he water must be potable free of corrosive chemicals sand dirt or other contaminates It is up to the installer to ensure the water does not contain corrosive chemicals or elements that can affect or d...

Страница 30: ...te trap is not affected by the auto drain down solenoid valves and will have to be manually drained Winterizing These recommendations are intended to suggest practices which are effective for winteriz...

Страница 31: ...lons of undiluted virgin food grade white vinegar into pail 6 Place the drain hose H3 and the hose H2 to the pump inlet into the cleaning solution 7 Open both service valves V1 and V2 on the hot water...

Страница 32: ...tap and confirm that water flows and then close 6 Turn on the power 7 After confirming that the temperature controller is off turn on the gas supply 8 Turn on the temperature controller Running a low...

Страница 33: ...s used It can be activated by a push button motion sensor or voice activation but not by a temperature sensor A timer added to a standard recirculating pump is not considered as on demand 2 The air ha...

Страница 34: ...n product installed in a closed loop application commonly associated with space heating only applications The integrated controller on indoor models has a 1 year warranty on parts There is no warranty...

Страница 35: ...NOTES...

Страница 36: ...U340 1338 02 100000561 03 7 2019...

Отзывы: