Rinnai RU180iN Скачать руководство пользователя страница 34

 

34

 

V53De Manual

 

Proof of purchase is required to obtain warranty service. You may show proof of purchase with a dated sales 

 

receipt, or by registering within 30 days of purchasing the product. To register your Rinnai Tankless Water 

 

Heater, please visit www.rinnai.us. For those without internet access, please call 1

-

800

-

621

-

9419. Receipt of 

 

registration by Rinnai will constitute proof

-

of

-

purchase for this product. Registration of product installed in new 

home construction may be verified with a copy of the closing papers provided by the initial home buyer. 

 

However, registration is not necessary in order to validate this Limited Warranty.

 

  

Accident, abuse, or misuse

 

  

Alteration of the product or any component part

 

  

Misapplication of this product

 

  

Improper installation (such as but not limited to)

 

− 

Product being installed in a corrosive envi-
ronment

 

− 

Condensate damage

 

− 

Improper venting

 

− 

Incorrect gas type

 

− 

Incorrect gas or water pressure

 

− 

Absence of a drain pan under the appliance

 

• 

Improper maintenance (such as but not limited 
to scale build

-

up, freeze damage, or vent 

 

blockage)

 

• 

Incorrect sizing

 

  

Any other cause not due to defects in materials 
or workmanship

 

  

Problems or damage due to fires, flooding, 

 

electrical surges, freezing or any acts of God

 

• 

Any damage caused by poor water quality

 

• 

Operating the water heater with anything other 
than potable water at all times

 

  

Force majeure

 

What is Not Covered?

 

This Limited Warranty does not cover any failures or operating difficulties due to the following:

 

There is no warranty coverage on product installed in a closed loop application, commonly associated with space 
heating only applications.

 

The integrated controller on indoor models has a 1 year warranty on parts.

 

There is no warranty coverage for commercial applications.

 

This Limited Warranty does not apply to any product whose serial number or manufacture date has been 

 

defaced.  

 

This Limited Warranty does not cover any product used in an application that uses chemically treated water such 
as a pool or spa heater. 

 

Limitation on Warranties

 

No one is authorized to make any other warranties on behalf of Rinnai America Corporation. Except as expressly 
provided herein, there are no other warranties, expressed or implied, including, but not limited to warranties of 
merchantability or fitness for a particular purpose, which extend beyond the description of the warranty herein.

 

Any implied warranties of merchantability and fitness arising under state law are limited in duration to the 

 

period of coverage provided by this Limited Warranty, unless the period provided by state law is less. Some 
states do not allow limitations on how long an implied Limited Warranty lasts, so the above limitation may not 
apply to you.

 

Rinnai shall not be liable for indirect, incidental, special, consequential or other similar damages that may arise, 
including lost profits, damage to person or property, loss of use, inconvenience, or liability arising from improper 
installation, service or use.

 

Some states do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation may not apply to you.

 

This Limited Warranty gives you specific legal rights, and you may also have other rights which vary from state to 
state.

 

 

www.rinnai.us/warranty 

 

Содержание RU180iN

Страница 1: ...manual must be left for the consumer The consumer must read and refer to this manual for proper operation and to maintain the water heater If the information in these instructions is not followed exa...

Страница 2: ...Electricity 13 Installation of Temperature Controller 14 Mounting the Controller 15 Final Checklist 16 Technical Data 17 Specifications 17 Dimensions 18 Pressure Drop and Water Flow Curves 19 Ladder...

Страница 3: ...diately below the water heater or by turning off the water supply to the building WARNING AVERTISSEMENT Use only your hand to push in or turn the gas control knob Never use tools If the knob will not...

Страница 4: ...d water This appliance is suitable for filling large or whirlpool spa tubs with potable water Do not use substitute parts that are not authorized for this appliance MUST DO The installation must confo...

Страница 5: ...onment water quality and need for freeze protection Requirements for the gas line water lines electrical connection and Should overheating occur or the gas supply fail to shut off turn off the manual...

Страница 6: ...30 cm for appliances 10 000 Btuh 3 kW and 100 000 Btuh 30 kW 36 in 91 cm for appliances 100 000 Btuh 30 kW 4 ft 1 2 m below or to side of opening 1 ft 300 mm above opening K Clearance to a mechanical...

Страница 7: ...that are found in aerosol sprays detergents bleaches cleaning solvents oil based paints varnishes and refrigerants The air in beauty shops dry cleaning stores photo processing labs and storage areas f...

Страница 8: ...Mobile Homes Leave the entire manual taped to the temperature controller if installed or give the entire manual directly to the consumer Mount to Wall 1 Identify the installation location and confirm...

Страница 9: ...Z21 22 and or the standard Temperature Pressure Temperature and Pressure Relief Valves and Vacuum Relief Valves CAN1 4 4 The relief valve must be rated up to 150 psi and to at least the maximum BTU h...

Страница 10: ...ump Solenoid Valve Boiler Drain Valve KEY This is not an engineered drawing It is intended only as a guide and not as a replacement for professionally engineered project drawings This drawing is not i...

Страница 11: ...rmance Installation of Gas Supply MUST DO A manual gas control valve must be placed in the gas supply line to the water heater A union can be used on the connection above the shut off valve for the fu...

Страница 12: ...the 3 4 inch pipe size is capable of supplying 188 FT3 HR of natural gas Gas Input of all gas products BTU HR Heating Value of Gas BTU FT 3 Cubic Feet per Hour CFH Any compound used on the threaded jo...

Страница 13: ...klist for Gas and Electricity A manual gas control valve is placed in the gas line to the water heater Check the gas lines and connections for leaks Confirm that the gas inlet pressure is within limit...

Страница 14: ...Controllers Maximum Cable Length for each Controller to Water Heater 1 328 ft 100 m 2 164 ft 50 m 3 or 4 65 ft 20 m Turn the power off Do not attempt to connect the temperature controllers with the p...

Страница 15: ...using the holes drilled in step 2 7 Disconnect power from the water heater 8 Remove the screw on the Quick Cable Connector Fig 1 9 Rotate the Quick Cable Connector Fig 2 10 Route the wires through th...

Страница 16: ...t pressure is within limits Confirm that the water heater is rated for the gas type supplied Confirm that the electricity is supplied from a 120 VAC 60 Hz power source is in a properly grounded circui...

Страница 17: ...more information 140 F 60 C Minimum Temperature Setting 115 F 46 C Weight 29 7 lb 13 5 kg Noise level 54 dB Electrical Consumption Normal 50W Standby 2 W Anti frost Protection 64W Max Current 1 2A Fu...

Страница 18: ...ot Water Outlet from wall 3 4 87 F Hot Water Outlet from center 4 1 105 G Cold Water Inlet from wall 2 7 68 H Cold Water Inlet from center 0 4 10 I Gas Connection from wall 3 0 77 J Gas Connection fro...

Страница 19: ...V53De Manual 19 Pressure Drop Curve Water Flow Curve 0 0 1 0 2 0 3 0 4 0 5 0 6 0 0 25 50 75 100 125 150 delta T Temperature Rise F Pressure Loss ft head Water Flow gpm Water Flow gpm Pressure Loss psi...

Страница 20: ...20 V53De Manual Ladder Diagram...

Страница 21: ...product s you registered and or you account with us Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Leave...

Страница 22: ...eau m me partiellement Faites inspecter l appareil par un technicien qualifi et remplacez toute partie du syst me de contr le et toute commande qui ont t plong s dans l eau TO TURN OFF GAS TO APPLIANC...

Страница 23: ...art of the control system and any gas control which has been under water N utilisez pas cet appareil s il a t plong dans l eau m me partiellement Faites inspecter l appareil par un technicien qualifi...

Страница 24: ...water sources are able to provide water at this temperature setting until it is changed again at this or another temperature controller DANGER Hot water can be dangerous especially for infants or chi...

Страница 25: ...cked by pressing the Priority button and the up button together for 5 seconds A beep will sound confirming that the controller is locked The display will alternately show LOC the temperature setting a...

Страница 26: ...Push Button 3 PB3 White MENU button cycles through available menus 1 2 3 4 5 and 6 see table below 4 Push Button 4 PB4 White VALUE button cycles through available menu values see table below 5 Push B...

Страница 27: ...and or regulator is sized properly Ensure gas type and pressure is correct Bleed all air from gas lines Ensure condensation collar was installed properly Verify dip switches and programming parameter...

Страница 28: ...istance of motor winding 70 PC Board Replace the PC Board 71 Solenoid Valve Circuit Replace the PC Board 72 Flame Sensing Device Verify flame rod is touching flame when unit fires Check all wiring to...

Страница 29: ...he water must be potable free of corrosive chemicals sand dirt or other contaminates It is up to the installer to ensure the water does not contain corrosive chemicals or elements that can affect or d...

Страница 30: ...te trap is not affected by the auto drain down solenoid valves and will have to be manually drained Winterizing These recommendations are intended to suggest practices which are effective for winteriz...

Страница 31: ...lons of undiluted virgin food grade white vinegar into pail 6 Place the drain hose H3 and the hose H2 to the pump inlet into the cleaning solution 7 Open both service valves V1 and V2 on the hot water...

Страница 32: ...tap and confirm that water flows and then close 6 Turn on the power 7 After confirming that the temperature controller is off turn on the gas supply 8 Turn on the temperature controller Running a low...

Страница 33: ...s used It can be activated by a push button motion sensor or voice activation but not by a temperature sensor A timer added to a standard recirculating pump is not considered as on demand 2 The air ha...

Страница 34: ...n product installed in a closed loop application commonly associated with space heating only applications The integrated controller on indoor models has a 1 year warranty on parts There is no warranty...

Страница 35: ...NOTES...

Страница 36: ...U340 1338 02 100000561 03 7 2019...

Отзывы: