CARE AND MAINTENANCE

TROUBLE SHOOTING CHECKLIST

Use the following chart to help determine whether a service call is required, however if you are unsure
about the way your heater is operating, contact Rinnai or your local agent.

ERROR CODES 

Fault 
Condition

Probable 
Cause

No Dis

p

lay on remote

No i

g

n

iti

on

 or co

ntr

o

l

pa

nel

 in

di

ca

tors

Burn

ers fail

 to

 ig

ni

te

Co

mb

us

ti

on s

top

s

du

ring

 o

p

e

rati

o

n

Sme

ll of ga

s

Rem

o

te control

do

es

n

’t w

o

rk

Possible Remedy

Not plugged in or turned off.

Plug in power cord or press On/Off 

 button.

Mains power failure.

Use power failure reset procedure on page 7.

(Initial Install) Air in gas pipe.

Installer to purge air from gas supply.

Filter obstructed.

Remove and clean filters.

Gas escape.

Isolate gas supply, call Rinnai service, page 28.

On Timer set.

Use the Override as described on page 11.

Lock set.

Cancel Lock as described on page 11.

Gas supply turned off.

Turn gas supply on at the meter or cylinder.

Flat batteries.

Replace remote control batteries 2 x 1.5v (AAA).

Remote Control lock-up due
to mis operations such as
the remote signal being out
of range, incorrectly aimed
or obstructed.

Press the STANDBY/ON 

 button.

Your Rinnai space heater is also fitted with self diagnostic electronics that
monitor the appliance during start-up and operation.

Should a fault occur the heater will shut down, the fault that has caused the
shut down will be indicated by a pair of flashing digits in the Error Display 
window and a ‘Green’ flashing Operation Indicator 

Refer to the table below for probable cause and the suggested remedy.

Code

Probable Cause

Suggested Remedy

00

Mains power failure

To reset the heater, press the On/Off 

 button twice or use

the remote control and press the STANDBY/ON 

 button

once for stand-by mode, press the STANDBY/ON 
button a second time to set the heater to On.

11

Ignition failure

Check gas supply is turned on, switch the heater to Standby
and then On again. If ignition failure continues to occur a
Service call will be required.

12

Incomplete combustion

As above

14

Filter Blockage / Overheat

Clean filters, if error continues service call.

16

Room overheat

Lower room temp to below 40°C.

31

Room temperature sensor faulty

Service call.

32

Overheat temperature sensor faulty

Service call.

33

Overheat temperature sensor faulty

Service call.

53

Spark sensor faulty

Service call.

61

Combustion fan motor faulty

Service call.

71

Solenoids faulty

Service call.

72

Flame detection circuit fault

Service call.

73

Communication error

Service call.

11

10

8

7

8

10

STANDBY

ON

11

11

11

Содержание RHFE-752ETR

Страница 1: ...ce Heater RHFE 752ETR This appliance shall be installed in accordance with Manufacturer s Installation Instructions Current AS NZS 3000 AS NZS 5601 Local Regulations and Municipal Building Codes This...

Страница 2: ...ai RHFE 752ETR Flamefire We trust you will have many years of comfort and enjoyment from your appliance BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL...

Страница 3: ...__________________________________ Certificate of Compliance Certification Number ______________________________ Authorised Persons Licence Number _______________________________________ Installers Si...

Страница 4: ...PERATION WITHOUT THE REMOTE CONTROL AUTOMATIC MODE 7 OPERATION WITH THE REMOTE CONTROL 7 TURNING ON THE POWER 8 ADJUSTING THE TEMPERATURE 8 FLAME FUNCTION 9 REMOTE CONTROL BATTERIES 9 PROGRAMMED HEATE...

Страница 5: ...plied in 3 separate cartons the following tables list which components are in each carton Ensure that the components listed are present before proceeding with the installation Component Descriptions C...

Страница 6: ...URNER MEDIA 4 LOUVRE WARM AIR DISCHARGE 5 RECEIVER WINDOW BLOCKAGE INDICATOR Remote control receiver Indicator for filter louvre blockages 6 3 3 ON OFF BUTTON Turns the heater On or Off 7 8 9 10 7 OPE...

Страница 7: ...it wet FRONT REAR BATTERY COMPARTMENT COVER STANDBY ON Flame Lock Timer 2 Timer 1 Override Time Set Temperature Lock Clock AM PM Timer 1 Set Set ON OFF ON OFF Timer 2 Set Override ExtraLow Time Flame...

Страница 8: ...The Dual Timer feature means that you can Set and Forget your heater It will turn itself ON or to STANDBY at the times you have programmed until you cancel the Timer program Pre Heat This function aut...

Страница 9: ...raining d Heat emanating from the front of this appliance may over time affect the appearance of some materials used for flooring such as carpet vinyl cork or timber This effect may be amplified if th...

Страница 10: ...warm air discharge louvres and glass must be avoided DO NOT allow young children or the infirm to sleep directly in front of the heater DO NOT allow anyone to sit on or lean against the appliance DO N...

Страница 11: ...ration in this manner is known as automatic mode In automatic mode the default set temperature is 22 C For operation in other modes the remote control must be used OPERATION WITH THE REMOTE CONTROL Fo...

Страница 12: ...the flames as this may cause damage The convection fan is required to continue operation for several minutes after extinction of the flames to assist cooling Turning The Heater On When the heater is i...

Страница 13: ...hould the room temperature reach 40 C whilst the flame function is activated the heater will switch off automatically This is a safety feature REMOTE CONTROL BATTERIES Use 2 x 1 5V AAA batteries NEVER...

Страница 14: ...ayed briefly to confirm settings When the programs have been received the Remote Display will revert to Time mode and After battery replacement the clock and timers may need to be re programmed PRE HE...

Страница 15: ...ns when the room temperature keeps rising even when the heater is on the lowest heat setting Extra Low Function OFF When the room temperature reaches the preset temperature with the Extra Low function...

Страница 16: ...to come on before cleaning filters DO NOT continue to use the heater once this Indicator is flashing When an obstructive build up is detected the Blockage Indicator LED which is located above the Rece...

Страница 17: ...stat operates This is the sound of the solenoid gas valves opening and closing to regulate the gas flow amd is normal When the appliance is turned off Convection fan continues to run after turning off...

Страница 18: ...Rinnai space heater is also fitted with self diagnostic electronics that monitor the appliance during start up and operation Should a fault occur the heater will shut down the fault that has caused t...

Страница 19: ...LOCATION 20 HEATER INSTALLATION 21 1 UNPACKING THE APPLIANCE 21 2 CONNECTING THE APPLIANCE TO THE CONSUMER PIPING 21 3 OPENING THE FLUE SYSTEM ACCESS PANEL 21 4 HEATER BODY INSTALLATION 22 5 CONNECTI...

Страница 20: ...System Fan assisted twin chamber coaxial flue system provides air for combustion to the appliance and allows expulsion of combustion products to atmosphere Results in room sealed appliance Convection...

Страница 21: ...nai ASP ES Flue components MUST BE used The Rinnai RHFE 752ETR MUST NOT be flued into natural draft flue system or via a chimney Consult the Rinnai Power Flued Flamefire Space Heater Co axial Flue Sys...

Страница 22: ...he lower right of the appliance If a left hand entry is required contact Rinnai for details Rinnai recommend the heater be plugged into a 240V 10A earthed power point The power point must be a maximum...

Страница 23: ...SWTKIT Order number of lengths as required Flue is NOT to be terminated under the floor or in a roof space Down Out and vertical through roof flue installations are permitted ONLY when the flue termin...

Страница 24: ...ombustion air intake 500 300 Appliances up to 150 MJ h input 500 300 Appliances over 150 MJ h input up to 200 MJ h input 1500 300 Appliances over 200 MJ h input up to 250 MJ h input 1500 500 Appliance...

Страница 25: ...panel by removing the four retaining screws Extend the flexible gas connection through the gas fitting access point to the outside of the heater body Position the appliance in front of the enclosure s...

Страница 26: ...MUST BE made in accordance with the Rinnai Power Flued Flamefire Space Heater Co axial Flue System Installation Manual supplied with flue kits ASPDFK or ASPKIT03 Ensure the flue spigot of the heater i...

Страница 27: ...edia Small Media Option I Place burner media in the gap between the glass retaining wall and the stainless steel burner media shelf until it has been completely filled DO NOT place the burner media on...

Страница 28: ...media shelf until it has been completely filled DO NOT place the small burner media on top of or above the level of the glass retaining wall Place burner media evenly and AVOID any large gaps between...

Страница 29: ...o securing screws Follow the commissioning instructions to complete the gas pressure adjustments Check for the full and correct operation of the appliance Replace the top panel and secure with screws...

Страница 30: ...nced During this period the heater should be operated on High and the space being heated should be well ventilated For protection of young children or the infirm a secondary guard is required Ensure t...

Страница 31: ...R 4 pl gy or y or 8 6 3 4 1 SP bl POV gy gy R TH OH TH 2 TF OH TH 1 F 3A gr y bl br MED LO COM HI y r w bl COM HI MED LOW w bk r bl 1 1 4 4 w bk r bl w bk r 1 1 3 3 CONTROL DISPLAY UNIT 1 2 1 2 1 2 2...

Страница 32: ...local call Higher from mobile or public phones Australia Pty Ltd ABN 74 005 138 769 Internet www rinnai com au E mail enquiry rinnai com au Rinnai has a Service and Spare Parts network with personnel...

Отзывы: