The water heater can deliver water at only one temperature setting at a time. The available temperatures are provided
below. A temperature lower than 98° F (37° C) can be obtained at the tap by mixing with cold water.
To change the temperature scale from Celsius to Fahrenheit or vice versa, press and hold the
“
On/Off
”
button on the
controller for 5 seconds while the water heater is OFF.
*
These models have a default maximum temperature of 120° F (49° C) and an option to increase the maximum temperature to 140 °F (60 °C).
Refer to section
“3.12
Parameter Settings
”
for further details.
Temperature Settings
Fahrenheit °F
98
100
102
104
106
108
110
115
120
125
*
130
*
135
*
140
*
150
**
160
**
185
**
Celsius °C
37
38
39
40
41
42
43
46
49
52
54
57
60
66
71
85
Available Temperatures with an Internal Controller
4.4 Performance Data
**
These settings require the installation of the MCC
-
91
-
2 controller. When the MCC
-
91
-
2 controller is connected, these higher temperatures
are available on all controller models in the system. Use of an MCC
-
91
-
2 controller in a residential dwelling will reduce the warranty coverage
to that of a commercial warranty application.
To Obtain Performance Data:
1.
Press and hold the (Down) button.
2.
While holding the (Down) button for 2 seconds,
press and hold the
“
On/Off
”
button (hold both buttons
simultaneously).
3.
Use the (Up) and (Down) buttons to scroll to the
desired information described in the Performance
Data Table.
4.
To exit performance data, repeat step 2 above.
5.
When complete, the set temperature appears in the
display.
1
2
#
DATA
UNIT
0 1
Water Flow Rate
x0.1 gal/min
02
Outgoing Temperature
°F
03
Combustion Hours
x100 Hours
04
Combustion Cycles
*
05
Fan Frequency
Hz
06
Additional Controllers Connected
*
07
Water Flow Control Position
0=mid, 1=Open,
2=Closed
08
Inlet Temperature
°F
09
Fan Current
x10 mA
1 0
Total Bath Fill Amount
gallons
1 1
HEX Outlet Temperature
°F
12
By
-
Pass Flow Control Position
Degrees of opening
15
Freeze Protection Temperature
(Indoor Unit Only)
°F
17
Freeze Protection Temperature
(Outdoor Unit Only)
°F
19
Pump Hours
x100 Hours
20
Pump Cycles
*
2 1
Exhaust Temperature
°F
Performance Data Table
* Refer to the Technical Data Sheet located on the inside
front cover of the water heater for additional information.
#
DATA
UNIT
0 1
Water Flow Rate
x0.1 gal/min
02
Outgoing Temperature
°F
03
Combustion Hours
x100 Hours
04
Combustion Cycles
*
05
Fan Frequency
Hz
06
Additional Controllers Connected
*
07
Water Flow Control Position
0=mid, 1=Open,
2=Closed
08
Inlet Temperature
°F
09
Fan Current
x10 mA
1 0
Total Bath Fill Amount
Gallons
1 1
HEX Outlet Temperature
°F
12
By
-
Pass Flow Control Position
Degrees of opening
15
Freeze Protection Temperature
(Indoor Units Only)
°F
17
Freeze Protection Temperature
(Outdoor Units Only)
°F
19
Pump Hours
x100 Hours
20
Pump Cycles
*
2 1
Exhaust Temperature
°F
Performance Data Table
* Refer to the Technical Data Sheet located on the inside
front cover of the water heater for additional information.
Содержание REU-N2024FF-US
Страница 66: ...66 Rinnai Tankless Water Heater Installation and Operation Manual 6 Appendices 6 1 Wiring Diagram PC BOARD...
Страница 67: ...Rinnai Tankless Water Heater Installation and Operation Manual 67 6 2 Ladder Diagram...
Страница 74: ...74 Rinnai Tankless Water Heater Installation and Operation Manual 7 Notes...
Страница 75: ...Rinnai Tankless Water Heater Installation and Operation Manual 75 Notes...
Страница 76: ...76 Rinnai Tankless Water Heater Installation and Operation Manual 100000467 05 8 2019...