Before operating, smell all around the appliance area 

for

 

gas. Be sure to smell next to the floor because 

some gas is heavier than air and will settle on the 

floor.

 

• 

Keep the area around the appliance clear and free 

from combustible materials, gasoline, and other 

flammable vapors and liquids.

 

• 

Combustible construction refers to adjacent walls and 

ceiling and should not be confused with combustible 

or flammable products and materials. Combustible 

and/or flammable products and materials should 

never be stored in the vicinity of this or any gas 

appliance.

 

• 

Always check the water temperature before entering a 

shower or bath.

 

• 

To protect yourself from harm, before performing 

maintenance:

 

− 

Turn off the electrical power supply by unplugging 

the power cord or by turning off the electricity at 

the circuit breaker. (The temperature controller 

does not control the electrical power.)

 

− 

Turn off the gas at the manual gas control valve, 

usually located immediately below the water 

heater.

 

− 

Turn off the incoming water supply. This can be 

done at the isolation valve immediately below the 

water heater or by turning off the water supply to 

the building.

 

− 

Use only your hand to turn the manual gas control 

valve. Never use tools. If the manual gas control 

valve will not turn by hand, do not try to repair it; 

call a trained and qualified professional. Force or 

attempted repair may result in a fire or explosion.

 

• 

Do not use this appliance if any part has been under 

water. Immediately call a licensed professional to 

inspect the appliance and to replace any part of the 

control system and any manual gas control valve 

which has been under water.

 

(N

utilisez pas cet appareil s

il a été plunge dans l

eau, 

même partiellement. Faites inspecter l

appareil par un 

licence professionnelle et remplacez toute partie du 

système de contrôle et toute commande qui ont été 

plongés dans l

eau.)

 

• 

Do not use substitute materials. Use only parts 

certified for the appliance.

 

• 

Should overheating occur or the gas supply fail to shut 

off, turn off the manual gas control valve to the 

appliance.

 

(En cas de surchauffe ou si l

alimentation en gaz ne 

s

arrête pas, fermez manuellement le robinet d

arrêt 

de l

admission de gaz.)

 

• 

Only trained and qualified professionals are permitted 

to adjust parameter settings. 

 

• 

Do not use an extension cord or adapter plug with this 

appliance.

 

• 

Any alteration to the appliance or its controls can be 

dangerous and will void the warranty.

 

• 

Proper venting is required for the safe operation of 

this appliance.

 

• 

Flammable liquids such as cleaning solvents, aerosols, 

paint thinners, adhesives, gasoline and propane must 

be handled and stored with extreme care. These 

flammable liquids emit flammable vapors and when 

exposed to an ignition source can result in a fire 

hazard or explosion. Flammable liquids should not be 

used or stored in the vicinity of this or any other gas 

appliance.

 

• 

DO NOT operate the water heater without the front 

panel installed. The front panel should only be 

removed for service/maintenance or replacing internal 

components.

 

• 

BURN HAZARD. Hot exhaust and vent may cause 

serious burns. Keep away from the water heater. Keep 

small children and animals away from the water 

heater.

 

• 

Hot water outlet pipes leaving the water heater can be 

hot to touch. 

 

• 

Do not store or use gasoline or other flammable 

vapors and liquids in the vicinity of this or any other 

appliance.

 

(Ne pas entreposer ni utiliser d

essence ou ni d

autres 

vapeurs ou liquides inflammables à proximité de cet 

appareil ou de tout autre appareil.)

 

• 

Install the vent system per local and national codes.

 

• 

Do not install this water heater above 10,200 ft 

 

(3,109 m).

 

• 

Do not obstruct combustion air to the water heater. 

 

• 

Failure to properly vent this appliance can result in 

death, personal injury and/or property damage.

 

• 

Rinnai recommends that every home have a carbon 

monoxide (CO) alarm in the hallway near bedrooms in 

each sleeping area. Check batteries monthly and 

replace them annually. 

 

• 

California law requires the following Proposition 65 

warning to be provided: 

 

 

1.2   Safety Precautions

 

The following precautions apply to the installer and consumer. Read and follow all instructions in this section. 

 

     WARNING

 

   

 

 

 

DO NOT adjust the internal gas valve. The design is such that adjustment is not 

   

   

 

 

 

required. Warranty will be voided if the internal gas valve is adjusted.

 

WARNING

 

 

This product can expose you to chemicals including 

lead, lead compounds and carbon disulfide which 

are known to the State of California to cause cancer, 

birth defects or other reproductive harm.  For more 

information, visit www.P65Warnings.ca.gov. 

 

Содержание REU-N2024FF-US

Страница 1: ...allumer d appareil Ne touchez aucun interrupteur ne pas vous servir des t l phones se trouvant dans le b timent Appelez imm diatement votre fournisseur de gaz depuis un voisin Suivez les instructions...

Страница 2: ...3 8 Pressure Relieve Valve 43 3 9 Condensate 45 3 10 Connect the Gas Supply 47 3 11 Connect the Power Supply 50 3 12 Parameter Settings 51 3 13 External Pump with Circ Logic 52 3 14 Service Indicator...

Страница 3: ...manual before installing the water heater The water heater must be installed according to the exact instructions in this manual Proper installation is the responsibility of the installer When install...

Страница 4: ...n personal injury or death Indicates a potentially hazardous situation which if not avoided could result in minor or moderate injury It may also be used to alert against unsafe practices Safety alert...

Страница 5: ...et d arr t de l admission de gaz Only trained and qualified professionals are permitted to adjust parameter settings Do not use an extension cord or adapter plug with this appliance Any alteration to...

Страница 6: ...eens x2 and vent screen screws x2 for internal indoor water heaters only The vent screen prevents debris and other objects from entering the terminal One vent screen is for the intake the other is for...

Страница 7: ...res and communicates with the service provider portal The Control R Wi Fi Module and MC 195T US controller are not compatible accessories and must not be installed together Recirculation Pump A pump s...

Страница 8: ...PM 38 L min 9 GPM 34 L min 7 GPM 26 L min 11 GPM 42 L min 10 GPM 38 L min 9 GPM 34 L min 7 GPM 26 L min Weight 64 lb 29 kg 64 lb 29 kg 62 lb 28 kg 62 lb 28 kg 64 lb 29 kg 64 lb 29 kg 62 lb 28 kg 62 lb...

Страница 9: ...door Models RU199i RU180i RU160i and RU130i Front Panel View Side Panel View External Outdoor Models RU199e RU180e RU160e and RU130e Front Panel View Side Panel View 2 6 Dimensions Vent Connection 2 i...

Страница 10: ...0 Rinnai Tankless Water Heater Installation and Operation Manual Connections for Internal and External Water Heaters Pressure Relief Valve PRV M33 THREAD Bottom View of Water Heater Measurements in mm...

Страница 11: ...ressures less than or equal to 1 2 psi 3 5 kPa 13 84 in W C the appliance must be isolated from the gas supply piping by closing its individual manual shutoff valve You must follow the installation in...

Страница 12: ...information is intended to serve as general guidelines only and is not a complete list of water quality guidelines 3 2 Choose an Installation Location Air surrounding the water heater venting and vent...

Страница 13: ...ve Loss of freeze protection may result in water damage from a burst heat exchanger or water lines The water heater may be drained manually However it is highly recommended to install the optional Dra...

Страница 14: ...ounds in the air The water heater location complies with the required clearances The planned combustion air and exhaust termination locations meet the required clearances The water supply does not con...

Страница 15: ...ws on far left side and 2 screws on far right side Use the appropriate screws for the wall construction to secure the mounting bracket to the wall between two studs Securely screw the top and bottom b...

Страница 16: ...ake sure the water heater is straight Proper operation requires the water heater to be level Make sure the securing method is sufficient to support the weight of the water heater Refer to the water he...

Страница 17: ...ems vent connections must be firmly pressed together so that the connections form an air tight seal Follow the venting manufacturer s instructions Refer to the PVC CPVC manufacturer for appropriate fi...

Страница 18: ...locations near a dryer vent Avoid termination locations near commercial cooking exhaust Avoid termination locations near any air inlets You must install a vent termination at least 12 in above the gr...

Страница 19: ...er and a separate exhaust header that vents directly through separate penetrations to the outside Combustion Air Exhaust Exhaust Room Air For Combustion Twin Pipe Combustion air and exhaust vent direc...

Страница 20: ...29 www duravent com Royal 800 232 5690 www royalbuildingproducts com Ecco Manufacturing 877 955 4805 www eccomfg com DiversiTech 800 995 2222 www diversitech com Direct Vent Approved Vent Manufacturer...

Страница 21: ...x 40 in 20 ICRT2439 2 in x 4 in Concentric Roof Termination 20 2PPS VKL VK TCL 2 in x 4 in Vertical Termination Cap Kit Concentric 20 2PPS HKL 2 in x 4 in Horizontal Termination Kit Concentric 20 190...

Страница 22: ...above roof 5 196006 197009 FGV Concentric Vent Kit 3 in x 20 in 20 196106 197107 FGV Concentric Vent Kit 3 in x 32 in 20 196116 197117 FGV Concentric Vent Kit 3 in x 44 in 20 52CVKGVS6503 PVC 52CVKGV...

Страница 23: ...al Termination 16 3PPS VKL VK TCL 3 in x 5 in Vertical Termination Cap Kit Concentric 20 3PPS HKL 3 in x 5 in Horizontal Termina tion Kit Concentric 20 190388 3 in x 5 in Concentric Horizontal Termina...

Страница 24: ...in Pipe Termination 10 2PPS HSTL 2 in Single Horizontal Termination 6 2PPS TBL 2 in Black UV Resistant Tee 5 196984 FGV PVC Low Profile Termination Kit 5 081216 FGV PVC Wall Termination Kit 16 52SWVKG...

Страница 25: ...Horizontal Termination 5 3PPS TBL 3 in Black UV Resistant Tee 6 196985 FGV PVC Low Profile Termination Kit 5 081219 FGV PVC Wall Termination Kit 16 52SWVKGVS6503 PVC Side Wall Vent Kits 5 52WTVKGVS65...

Страница 26: ...64 CPVC Schedule 40 ANSI ASTM F493 PVC Vent Screens Termination Vent Screens Polyethylene 2 in Vent Screens included in carton box IPEX Part Number 196050 3 in Vent Screens IPEX Part Number 196051 Exh...

Страница 27: ...non mechanical air supply inlet to building or the combustion air inlet to any other appliance 36 in 91 cm 12 in 30 cm K Clearance to a mechanical air supply inlet 6 ft 1 83 m 3 ft 91 cm above if with...

Страница 28: ...ls at different levels Note 24 in 0 61 m to wall or parapet Combustion air and exhaust vent directly through a single concentric connection Hot exhaust exits through the interior tube while combustion...

Страница 29: ...Vent Maximum Equivalent Length Vent Sizes 2 in X 4 in 3 in X 5 in Vent Lengths 65 ft 20 m 150 ft 46 m 45 elbow is equivalent to 3 ft 1 m 90 elbow is equivalent to 6 ft 2 m Concentric Pipe Installatio...

Страница 30: ...case scenario of 3 X 90 elbows or 18 equivalent ft Twin Pipe Vertical Termination of Multiple Water Heaters Combustion air termination not permitted in shaded area Horizontal Vent and Combustion Air P...

Страница 31: ...he use of a pipe reducer installers can use a 3 in 76 mm pipe for the combustion air and exhaust Remove and discard the screw from the combustion air vent connection Remove and discard the combustion...

Страница 32: ...tion 2 in or 3 in PVC Low Profile Termination Configuration This configuration requires the use of a Concentric Vent Termination Exhaust and combustion air MUST NOT be brought together into a single P...

Страница 33: ...tance of 15 ft 4 m J Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 36 in 91 cm 4 ft 1 2 m below or to side of opening 1 ft 300 mm above op...

Страница 34: ...ipated snow level 2 in 0 91 m to ventilated or unventilated soffit or eve vent or to a deck or porch Termination Clearances for External Outdoor Water Heaters Exhaust Termination Clearances for Intern...

Страница 35: ...me is less than 50 cubic feet per 1000 Btu hr 4 8 m3 per kW per hour of the aggregate input rating of all appliances installed in that space Examples include a small room closet alcove utility room et...

Страница 36: ...e regulations therein Checklist for Combustion Air and Venting Requirements Location To maintain proper circulation of combustion air two permanent openings one upper one lower must be positioned in c...

Страница 37: ...ure with the supplied screw Use the room air screen for environments where room air is dusty Note 2 in vent screen supplied with water heater Room air screen is available as an accessory Glue elbow to...

Страница 38: ...Non Direct Vent Room Air Example Vent Applications Non Direct Vent Room Air Maximum Vent Length Non Direct Vent Room Air 2 Room Air Maximum Equivalent Length Table Vent Sizes 2 in 51 mm 3 in 76 mm 2 i...

Страница 39: ...ets on the back side of the water heater Installation Enclosure with Louvered Door for Manufactured Home Applications Use the following chart to identify the minimum required size of the opening in th...

Страница 40: ...ent Diameter Max System Btu hr 3 in 4 in 6 in RU199i REU N3237FF US RU180i REU N2934FF US 2 398 000 360 000 65 ft 20 m 150 ft 46 m 150 ft 46 m RU160i REU N2530FF US RU130i REU N2024FF US 2 320 000 260...

Страница 41: ...T Water connections to the water heater should follow all state and local plumbing codes If this is a standard installation refer to the Piping Diagram for Basic Installation below 1 Plumb the cold wa...

Страница 42: ...Hot Outlet side of the water heater 2 Hand tighten the Swivel Nut of the Hot Isolation Valve Red to the Hot Outlet side of the water heater 3 Rotate the Drain Valve to an accessible position With a wr...

Страница 43: ...Fahrenheit The pressure relief valve is assembled to the pressure relief valve adapter as illustrated on the next page DO NOT place any other valve or shut off device between the pressure relief valv...

Страница 44: ...the steps below 1 On the bottom of the tankless water heater hand tighten the Pressure Relief Valve Assembly and Gasket to the Pressure Relief Valve Union Fitting 2 Rotate the Pressure Relief Valve A...

Страница 45: ...on and an interior wall If a floor drain is not available or the drain is above the level of the condensate drain a condensate pump should be installed A condensate neutralizer kit is available from R...

Страница 46: ...Condensate Pump Safety Switch Installation NC NO COM Tankless Water Heater Test Operation 1 Test the operation of the shut off switch by unplugging the condensate pump and filling the condensate reser...

Страница 47: ...solutions including soap and water may cause corrosion or stress cracking the piping shall be rinsed with water after testing unless it has been determined that the leak test solution is non corrosive...

Страница 48: ...xample The appropriate table from the applicable code must be used Schedule 40 Metallic Pipe Inlet Pressure Less than 2 psi Specific Gravity 0 60 Gas Pipe Sizing Reference Tables Information in table...

Страница 49: ...24 147 308 580 1 190 90 27 138 289 544 1 120 100 30 131 273 514 1 060 Information in table obtained from NFPA 54 ANSI Z223 1 2015 Information in table obtained from NFPA 54 ANSI Z223 1 2015 Intended...

Страница 50: ...ly Connection Checklist When connecting the power supply follow these guidelines Do not rely on the gas or water piping to ground the water heater Ground locations are provided inside the water heater...

Страница 51: ...109 m 03 Service Soon1 Disabled 0 5 Year 1 Year 2 Years 04 Recirculation Settings No Recirculation Recirculation Dedicated 05 Recirculation Mode2 Economy Comfort 06 Control Switch BMS3 Air Handler AH...

Страница 52: ...gs the external pump cable is not included with the tankless water heater and must be purchased separately Circ Logic operates in either Economy or Comfort mode based on the parameter settings of the...

Страница 53: ...es to the tankless water heater are not interchanged Does the water supply to the heater have adequate pressure Is it free of chemicals Did you verify it does not exceed total hardness that will damag...

Страница 54: ...ndensate drain pipe is open to atmosphere GAS SUPPLY YES NO Did you verify the gas system is appropriately sized Did you verify the water heater is rated for the gas type supplied Have you performed a...

Страница 55: ...ch as chlorine or bleach that produce fumes These fumes can damage components and reduce the life of your appliance Damage and repair due to scale in the heat exchanger is not covered by warranty Alwa...

Страница 56: ...the beeps repeat the above steps 1 To lock the internal controller press and hold down the Priority button 2 While holding down the Priority button press the Up button until a beep is heard approxima...

Страница 57: ...when you are not getting hot water or if the water alternates between hot and cold it is due to the water flow being below or close to the minimum flow rate Increasing the flow rate should resolve the...

Страница 58: ...s to scroll to the desired information described in the Performance Data Table 4 To exit performance data repeat step 2 above 5 When complete the set temperature appears in the display 1 2 DATA UNIT 0...

Страница 59: ...ter Not Turning On Check that the gas is turned on at the water heater meter or cylinder If the system is propane make sure that gas is in the tank Ensure gas type and inlet gas pressure are correct B...

Страница 60: ...required to fire unit Measure the resistance of the water flow control sensor Clean inlet water supply filter On new installations ensure hot and cold water lines are not reversed 19 Electrical Groun...

Страница 61: ...professional must verify proper operation after servicing The following maintenance items are required for the proper operation of your water heater 5 Maintain the Water Heater 5 1 Maintenance VENT S...

Страница 62: ...and will have to be manually opened WINTERIZATION The following recommendations are intended to suggest practices that are effective for winterizing the water heater They should be used as a guide onl...

Страница 63: ...ecuring the front panel Remove the front panel and locate the filter at the upper right hand corner of the water heater Remove the air filter by pulling out the FILTER Pull to Clean tab 5 2 Cleaning a...

Страница 64: ...Allow water to flow through the water heater for five minutes d Close shutoff valve V4 When unit has finished draining remove the in line filter at the cold water inlet and clean out any residue Plac...

Страница 65: ...ater heater and the piping for leaks HOT COLD ON To avoid burns wait until the equipment cools down before draining the water The water in the appliance will remain hot after it is turned off WARNING...

Страница 66: ...66 Rinnai Tankless Water Heater Installation and Operation Manual 6 Appendices 6 1 Wiring Diagram PC BOARD...

Страница 67: ...Rinnai Tankless Water Heater Installation and Operation Manual 67 6 2 Ladder Diagram...

Страница 68: ...ase contact Rinnai Delta T Temperature Rise F Water Flow GPM Dashed lines represent flow rate after parameter adjustment RU130 RU160 RU180 RU199 6 3 Pressure Drop and Water Flow Curves Pressure Loss f...

Страница 69: ...Location The temperature controller should be out of reach of small children Avoid locations where the temperature controller may become hot near an oven or radiant heater Avoid locations in direct su...

Страница 70: ...er to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors A In the event that the side wall horizontally vented gas fueled equipment is...

Страница 71: ...Rinnai Tankless Water Heater Installation and Operation Manual 71 COMBINATION SPACE HEATING POTABLE WATER SYSTEM For Use In Commonwealth of Massachusetts Massachusetts State Regulations Continued...

Страница 72: ...curs first if the Rinnai Tankless Water Heater temperature settings exceed 160 F 71 C The integrated controller has a 1 year warranty on parts What Will Rinnai Do Rinnai will repair or replace the cov...

Страница 73: ...horized to make any other warranties on behalf of Rinnai America Corporation Except as expressly provided herein there are no other warranties expressed or implied including but not limited to warrant...

Страница 74: ...74 Rinnai Tankless Water Heater Installation and Operation Manual 7 Notes...

Страница 75: ...Rinnai Tankless Water Heater Installation and Operation Manual 75 Notes...

Страница 76: ...76 Rinnai Tankless Water Heater Installation and Operation Manual 100000467 05 8 2019...

Отзывы: