Ember specification
Ember 600 specification summary
Input
= 12-23 MJ/h
Output
= 2.5-5.0* kW
Efficiency
= 77% (on high)
Heating area = up to 85 m
2
**
Gas type
= NG or ULPG
Ember 700 specification summary
Input
= 14-27 MJ/h
Output
= 3-6.0* kW
Efficiency
= 77% (on high)
Heating area = up to 99 m
2
**
Gas type
= NG or ULPG
A direct vent inbuilt gas fireplace with a glass front
and convection fan, pushing warm air from the
top of the appliance. Operated with an infra-red
remote control.
Different burn media and frame options available.
* Will vary according to gas type and flue configuration.
** Will vary depending on geographical location in NZ.
Suitability
Suitable for masonry installations and installations
into a mock chimney, in open plan areas and living
rooms.
Data plate
Located on the lower RHS of the base panel in
front of the gas control.
Convection fan
120 V AC 50 Hz 2-speed centrifugal blower.
Lighting
Halogen lamps 240 V 25 W x 2.
Gas connection
Brass ½ “ BSPT male fitting, the gas supply
terminates inside the heater—lower right hand
side of the appliance.
Ignition
230-240 V AC 50 Hz high voltage electronic spark
generation unit.
Installation considerations
Room size—smaller rooms will heat up quickly,
and due to the efficiency of the appliance, the
Ember will turn to a low flame setting once the set
temperature has been reached.
For efficient performance Rinnai recommends
installing the fire as close to the floor as possible.
If the unit is installed higher up the wall the
movement of air from the convection fan,
depending on the room configuration, could
create draughts.
Noise level
: 37-45 dB(A)
Flueing: Masonry
Colinear flexi flue, air intake Ø 75 mm, exhaust
Ø 100 mm. Appliance must be installed with a
Rinnai Ember flue system.
Flueing: Mock chimney
Colinear (air intake Ø 75 mm, exhaust Ø 100 mm)
to coaxial direct vent flueing (inner Ø 100 mm,
outer Ø 170 mm). Appliance must be installed with
a Rinnai Ember flue system.
Electrical
This heater has a 1.5 m power cord with a three pin
plug supplied. The power cord passes through a
slot in the back left hand corner of the appliance.
t
High
= 110 W
t
Standby =
<1W
Safety devices
Flame failure sensing system, pressure relief,
overheat safety switch, air temperature sensor,
thermal fuse, overcurrent fuse, and spark
detector.
Temperature control
Once the unit is turned on the infra-red
remote* is used to control the flame
height and heat output.
If the remote is not used the Ember will
automatically modulate between the
burner settings to maintain the default
set temperature of 22 °C.
* Temperature sensor is located in the bottom of the remote
Weights
t
Ember 600 = 51 kg
t
Ember 700 = 55 kg
23
136 mm
34 mm