background image

  10  

 |   

Ember Installation Guide: 12890-A 01-17

Clearances from combustibles

The clearances listed below, measured from the 

edge of the glass

, are 

minimum clearances unless otherwise stated. 

While the heater is operating

The appliance must not be installed where 
curtains or other combustible materials 
could come into contact with the heater. 
The 400 mm side clearance includes side 
walls. The 1000 mm clearance is in front of 
the fire.

Floor protection

Heat from this fire may over time affect 
the appearance of some materials used 
for flooring, such as, carpet, vinyl, cork 
or timber. This may be amplified if the air 
contains cooking vapours or cigarette 
smoke. To avoid this occurring, it is 
recommended that a mat be placed in 
front of the appliance.

Mantels and surrounds

Combustible mantels and surrounds 
require clearance from the unit to 
minimise the risk of fire. Mantels and 
surrounds, made of combustible materials 
such as wood, are allowed providing they 
are outside the minimum clearances 
shown.

Hearths

A hearth is not necessary but can be used 
for decorative purposes or protection 
of sensitive flooring if required. A hearth 
must not obscure the front of the fire or 
obstruct the fire in any way (including the 
frame around the fire).

Wall surface above the fire

The temperature of the wall surface 
directly above the fire may get warm 
and distort paint finishes, or distort vinyl 
wall coverings. For durability of surfaces, 
please contact the manufacturer for their 
specification.

A

Mantel needs to be a min. of 400 mm away from the 
edge of the glass.

Max. mantel depth at 400 mm (A) is 250 mm max.

C

Surround needs to be a minimum of 400 mm away 
from the edge of the glass.

For every 50 mm of added mantel depth there must be 
an additional 100 mm of clearance from the edge of the 
glass. For example:

M

ANTEL

 

DEPTH

 

A

CLEARANCE

 

REQUIRED

300 mm  

500 mm

350 mm   

600 mm

400 mm  

700 mm

A

c

B- 

mantel depth

400 mm

400 mm

400 mm

1000 mm

Содержание RDV600L

Страница 1: ...Ember Installation guide Models RDV600N RDV600L RDV700N RDV700L...

Страница 2: ...Warning Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life For more information about buying using and servicing of Rinnai app...

Страница 3: ...the spigot plate 19 Burn media installation 20 Adding some of the granules and the glass 21 Log set installation 22 Stone set installation 24 Commissioning 26 Installing the frame 27 Test operation an...

Страница 4: ...ngine comes with remote control batteries inserted operation and installation guides granule packs rockwool crushed glass and exible gas connection 4 sided or 3 sided frame Zero clearance frame In ll...

Страница 5: ...e to the e ciency of the appliance the Ember will turn to a low ame setting once the set temperature has been reached For e cient performance Rinnai recommends installing the re as close to the oor as...

Страница 6: ...rame masonry installations or mock chimney installations with a hearth 580 640 618 380 590 18 287 Ember 600 with 4 sided frame mock chimney installations 580 640 644 380 590 26 18 287 695 790 95 95 60...

Страница 7: ...llations 618 740 380 590 680 18 312 740 644 380 590 26 680 18 312 658 825 92 5 92 5 700 695 890 95 95 Ember 700 with 3 sided frame masonry installations or mock chimney installations with a hearth 640...

Страница 8: ...The use of a rubber hose for any gas connection to a xed appliance is not authorised by the manufacturer Electrical supply The Ember is tted with a 1 5 m power cord and 3 pin plug The power cord passe...

Страница 9: ...x 200 mm for the two exi ues to t down the chimney Corner installations The Ember must be positioned within the enclosure on a at level surface that allows free movement of the appliance The enclosure...

Страница 10: ...re Mantels and surrounds made of combustible materials such as wood are allowed providing they are outside the minimum clearances shown Hearths A hearth is not necessary but can be used for decorativ...

Страница 11: ...n mock chimney installations which typically have mantels and surrounds made of combustible material The 4 sided frame sits approximately 26 mm below the engine refer dimension diagrams Glass width 54...

Страница 12: ...mm dimension The 400 mm dimension is the minimum clearance required to a mantel The image adjacent shows the dimension from the edge of the frame in the case of the Ember the 400 mm dimension is to b...

Страница 13: ...Ember Installation Guide 12890 A 01 17 13 Installation Installation servicing and repair shall be carried out only by authorised personnel...

Страница 14: ...in ll panel or masonry frame using the screws provided to the Ember engine using the top and bottom xings 7 Attach ue to the re Line up the spigot plate with the ue guide rails on top of the unit sli...

Страница 15: ...xhaust ues in the correct position The intake is on the left Flexi ues clamped and riveted screwed in place to the engine spigot plate Due to the weight it s best to support the underside of the plate...

Страница 16: ...place 5 Cladding A sheet of cladding can be applied over the whole section until the Ember is ready to be installed A hole can be cut using the zero clearance frame as the template 6 Attach exi ues to...

Страница 17: ...earance to a combustible surface Flue pipes twist and lock into place Colinear to coaxial adaptor supported and secured in place Flexi ues clamped and screwed to the connections Base of enclosure MUST...

Страница 18: ...note that the bottom strip of the zero clearance frame sits level with the bottom of the cavity 3 Remove bottom strip Once the zero clearance frame is securely xed the bottom strip needs to be removed...

Страница 19: ...l on either side of the engine The spigot plate slides in and out of this Flue clamp holding the ue onto the spigot plate Important This also needs to be screwed riveted in place to stop any movement...

Страница 20: ...be interchanged The Ember 600 and 700 burn media sets are di erent The Ember 600 stone set has six less stones and the log set is narrower and shorter ensure you have the correct kit before starting...

Страница 21: ...ay in position There are lower slots in the tray allowing the tray to be lifted o leaving the screws in place 2 Carefully empty the bag of glass into the mesh tray and level out 3 From the granule pac...

Страница 22: ...or the Ember 600 and 700 are di erent Ember 600 is smaller the installation steps are the same the 700 has been used in these instructions Ember 600 Ember 700 1 2 3 4 4 4 Before adding the log set mak...

Страница 23: ...and three quarters Pinch and roll the rockwool into pea sized balls 600 35 700 50 and place in between the granules These can go over the burner ports as the material is designed for the ame to penetr...

Страница 24: ...ess stones the installation steps are the same Refer to p 20 for the correct installation order Ember 600 Ember 700 Before adding the stone set make sure the 7 granules and the glass packet have been...

Страница 25: ...Step 4 Adding the granules and rockwool Place DO NOT POUR the granules ensuring even coverage around the burner ports so as not to cause blockages You will use approx one bag of granules for both mode...

Страница 26: ...orrect operation of the appliance and return the commissioning sheet to its plastic pouch The gas pressures must be checked against those printed on the data plate of the appliance The pressures are f...

Страница 27: ...push button control panel to the engine s box 2 Slide the two top frame hangers into the corresponding frame slots on the Ember engine and push the lower section into the recess of the engine 3 Secure...

Страница 28: ...the appliance Continued di culty or delay in establishing a ame Flame appears either very short or very long Flame only burns part way across the burner Severe soot building up on the inside of the g...

Страница 29: ...1 bk br bl w TR 1 2 13 12 11 10 9 8 7 6 5 4 3 2 1 w w ER y w SV 1 FR2 FR1 r bl bl w y 2 1 3 FM HI COM LO ON OFF DISPLAY UNIT ON OFF gy or bl r gr y gr y 5A F POV SV 3 SV 2 p w bl w w y TF w w r bl L p...

Страница 30: ...inless steel inner galvanised steel outer aluminium inner coaxial ue These all have slightly di erent clearances to combustibles Flue cowl clearance To ensure products of combustion are cleared adequa...

Страница 31: ...ue pipe must be supported to prevent any downward sags Horizontal pipe sections should be supported every 1 2 m Wall straps can be used for this purpose The horizontal run of ue pipe must have a 20 m...

Страница 32: ...downwards slope can trap heat and become a re hazard t The horizontal ue length must not be greater than the vertical Dimensions are in mm unless otherwise stated Flueing options 400 20 295 255 900 mi...

Страница 33: ...1 Ember adaptor R3653 Refer p 30 for clearance to combustible information for the Ember adaptor N B Can t be more than 600 mm maximum as shown due to the heat from the colinear exi ues Flue pipe s 150...

Страница 34: ...ht 400 1200 max Vertical termination ue component Masonry chimney exi vertical ue kit R3652 actual chimney size needs to be at least 200 x 200 mm for the exi ues to t down the chimney Horizontal termi...

Страница 35: ...ds out to 8 m Kit includes ue cowl chimney ashing plate intake exi 75 mm LHS exhaust exi 100 mm RHS 455 mm 455 mm Mock chimney horizontal ue kit Code R3654 Coaxial horizontal ue kit that attaches to t...

Страница 36: ...s 150 mm R3630 230 mm R3631 300 mm R3632 450 mm R3633 600 mm R3634 900 mm R3635 1200 mm R3636 Pipe used to construct horizontal and vertical ueing Cannot be cut to size Once joined nominal length redu...

Страница 37: ...horizontal wall terminal for installed dimensions Box depth is 100 mm Horizontal wall terminal Code R3650 Aluminium ue terminal required fpr all horizontal terminations Depth with horizontal ashing ki...

Страница 38: ......

Страница 39: ......

Страница 40: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz Ember Installation Guide 12890 A 01 17...

Отзывы: