Rinnai Boil & Brew: Owner and installer guide: 20830-C 03-18
|
9
Model
Height
Width
Depth
Depth with tap
A
B
5 L
427 mm
303 mm
154 mm
264 mm
124 mm
412 mm
10 L
582 mm
342 mm
156 mm
266 mm
143 mm
563 mm
15 L
582 mm
342 mm
210 mm
320 mm
143 mm
563 mm
25 L
582 mm
422 mm
242 mm
352 mm
182 mm
563 mm
Location and clearances
The Rinnai Boil & Brew stores and dispenses water at or close to boiling point at all times it is
switched on. Due caution must be taken when choosing a location for the product so as to
minimise misuse.
Locate the unit above a sink draining board, close to
a cold water supply and a power outlet. For the 5 L
(RBBW0500), 10 L (RBBW1000), and 15 L (RBBW1500)
models, the location of the socket outlet/plug
should be such as to give the user safe access for
turning the unit on and off. The site should be
dry and waterproof, and in a position that meets
the minimum clearances shown below. These are
required to allow safe access for servicing.
The heater should be positioned at a height to suit
the items being filled.
The Rinnai Boil & Brew must be vertically mounted.
Before installation confirm suitability of all screws and plugs for use with the wall. If unsuitable
due to the wall type provide alternative fixings.
If rear entry services are to be used the necessary holes for these should be prepared prior to
hanging the unit.
Ensure the wall can support the full weight of the unit and that there are no hidden services
(electricity, gas, or water) below the surface of the wall.
300 mm
100 mm
250 mm
300-500 mm
Model
Plumbing access cut out C
D
E
5 L
85 x 55 mm
28 mm
10 mm
150 mm
10 L
85 x 55 mm
49 mm
10 mm
315 mm
15 L
85 x 55 mm
49 mm
10 mm
200 mm
25 L
85 x 65 mm
87 mm
10 mm
205 mm