About your Rinnai Boil & Brew

The Rinnai Boil & Brew is a permanently 

plumbed, wall-mounted electric water heater 

with an insulated hot water container. Water 

is heated by an electric  heating element and 

the temperature is controlled by a thermostat. 

As boiling water is drawn off, the unit refills 

with cold water. Any steam generated during 

the heating cycle is condensed and retained 

within the unit.

The easy to use lever tap is positioned far 

enough away from the spout to ensure 

steam-free handling. The spout is designed to 

minimise splashing when dispensing water.

Automatic reheating

Once installed the filling and heating cycle is 

completely automatic. 

To use

Place a cup under the outlet spout and pull 

the tap handle down. The tap handle is spring 

loaded, when released it will spring back to 

the off position.

If for some reason you need to dispense a 

large volume of water or empty the unit the 

tap handle can be pulled up and locked into a 

continuous flow position.

Switching off

If not connected to a timer we suggest 

switching the unit off if not being used for a 

period of time, for example over a weekend.

When not in use

If the unit has been switched off for a long 

period of time (for example, for over a week) 

it is advisable to draw off the water in the unit. 

This will ensure freshly boiled water, not stale 

water, is used to make your drinks.

Similarly, if left unused it is possible that some 

scale residue will collect in the outlet tap. This 

will cause the outlet water to appear milky for 

a short while. If this occurs it is recommended 

that the first few cups are drawn off and 

discarded.

Areas prone to freezing

Care must be taken to prevent the unit 

freezing. If thought to be frozen it must not be 

switched on. It must be left to thaw and must 

be inspected to ensure it is undamaged before 

use.

Installation by a licensed tradesperson

Only a licensed tradesperson can install, 

adjust, maintain, and service the Rinnai Boil & 

Brew. Any work carried out by a non-licensed 

tradesperson is illegal and will void any 

warranty.

Hold down to 
fill a cup

Pull up and lock 
into place for 
continuous flow

Содержание RBBW0500

Страница 1: ...ing water dispensers Owner and installer guide Boil Brew models 5 L RBBW0500 10 L RBBW1000 15 L RBBW1500 25 L RBBW2500 Installer Please leave this guide with the owner as it contains important safety and warranty information ...

Страница 2: ... or maintenance can cause property damage personal injury or loss of life The appliance is not to be used by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction Important For more information about buying using and servicing of Rinnai appliances call 0800 RINNAI 0800 746 624 Rinna...

Страница 3: ... Installation Specification summary 7 Dimensions 8 Locations and clearances 9 General installation 10 Water quality 12 Electrical supply and connections 13 Troubleshooting 14 Limited Warranty 15 Proof of purchase 18 Installer details 18 Register your Boil Brew 19 ...

Страница 4: ...lled up and locked into a continuous flow position Switching off If not connected to a timer we suggest switching the unit off if not being used for a period of time for example over a weekend When not in use If the unit has been switched off for a long period of time for example for over a week it is advisable to draw off the water in the unit This will ensure freshly boiled water not stale water...

Страница 5: ... V wiring and must only be removed by an authorised person Damaged components If any component is damaged it must be replaced by an authorised person using Rinnai replacement parts Hot water The water dispensed will at times be boiling or close to boiling due caution must be taken when using the system Child supervision Children should be supervised to ensure they do not play with any part of the ...

Страница 6: ...Installation Installation servicing and repair shall be carried out only by authorised personnel ...

Страница 7: ...ement size Amp rating 5 L 2 0 kW 10 A 10 L 2 4 kW 10 A 15 L 2 4 kW 10 A 25 L 3 0 kW 15 A Electrical supply 5 L 10 L 15 L comes with a 2 m cord 25 L is a fixed wired unit Voltage rating 230 240 V 50 Hz AC single phase Water supply pressure Minimum 87 kPa Maximum 1000 kPa Thermostats Electronic to control water temperature to boiling point Construction Outer casing White powder coated steel Thermal ...

Страница 8: ...8 Rinnai Boil Brew Owner and installer guide 20830 C 03 18 Dimensions mm width height depth depth with tap A A B plumbing access cut out C D 6 mm 8 mm Ø 12 mm 110 mm E 50 mm 25 mm ...

Страница 9: ... safe access for turning the unit on and off The site should be dry and waterproof and in a position that meets the minimum clearances shown below These are required to allow safe access for servicing The heater should be positioned at a height to suit the items being filled The Rinnai Boil Brew must be vertically mounted Before installation confirm suitability of all screws and plugs for use with...

Страница 10: ...he left side BSP vent overflow connector This overflow vent must be arranged so as to divert excess water steam or steam condensation into the sink or drain or to the exterior of the building The vent tube must be unrestricted be greater than 5 mm OD to avoid blockage have a continuous fall with a clear open end and must be left open to the atmosphere It cannot be connected to an open plumbing sys...

Страница 11: ...ai Boil Brew Owner and installer guide 20830 C 03 18 11 Front cover Faucet tap Drain plug Steam vent water overflow outlet Cold water inlet connection Electrical terminal block Reset button Main thermostat ...

Страница 12: ... carried out at the customer s own cost but Rinnai will reimburse any reasonable test costs where water quality is within the limits tabled Water Quality and Impurity Limits TDS Total Dissolved Solids Total Hardness CaCO3 Dissolved free CO2 pH Langelier Index Up to 600 mg L or ppm Up to 200 mg L or ppm Up to 25 mg L or ppm 6 5 8 5 Between 1 0 0 8 Most metropolitan water supplies fall within these ...

Страница 13: ...o the appliance must be capable of withstanding the appliance load Fixed wiring must be protected from contact with the appliance If the appliance is to be unused for significant periods of time running costs can be reduced by switching the unit off It is recommended that this is done automatically by incorporating a suitable timer in the supply to the unit The timer must be capable of switching a...

Страница 14: ...on tap outlet spout Scale debris under tap seal Damaged tap seal Clean tap outlet Remove and clean Replace tap seal No water coming out No water coming in through cold inlet Check water is turned on Stale taste to water Unit left unused for several days Empty and allow to refill before use Tap sticks open Dirt around handle pivot Clean with a stiff brush Unit does not heat on commissioning Element...

Страница 15: ... this product 12 months Replace or repair free of charge the supplied or fitted component if it fails due to faulty manufacture General warranty terms Rinnai reserves the right to make modifications and change specifications and its parts without notice For the purposes of the Consumer Guarantees Act 1993 Rinnai only guarantees the availability of repair facilities and spare parts for the express ...

Страница 16: ...s 5 Where the unit has not been sited in accordance with the installation instructions or installed such that normal service access is difficult a service charge will apply If at the discretion of the attending service person the installation is deemed illegal or access is dangerous service will be refused Any work required to gain reasonable access to the unit will be chargeable by the attending ...

Страница 17: ... unit has failed directly or indirectly as a result of poor water quality outside the limits specified 6 Where it is found that there is no fault with the unit and the issue is related to the installation or is due to power failure 7 Subject to any statutory provisions to the contrary Rinnai does not accept a liability for consequential damage or any incidental expenses resulting from any breach o...

Страница 18: ...se details in a safe place for future reference ATTACH YOUR PROOF OF PURCHASE HERE RECORD YOUR DETAILS OF PURCHASE BELOW Retailer Retailer address Date of purchase Product details Proof of purchase Installer details Company name Installer name Address Phone Mobile Signed Date ...

Страница 19: ..._____________________________ Street _________________________________________________________________ Suburb __________________________ City _________________ _______________ Postcode ________________________ Phone ______________________________ Email ___________________________ Your details First name _______________________ Last name __________________________ Company __________________________...

Страница 20: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz a touch of magic 20830 C ...

Отзывы: