SPECIFICATION

    

規格

Heat Input 

輸入熱

:

High Calorifi c Value

高熱

Low Calorifi c Value

L. P. G.

3.37 kW

2.97 kW

N. G.

3.72 kW

3.72 kW

Gas Inlet Connection

:

Ø9.5 Hose End

燃氣入口接駁

:

Ø9.5

 

毫米接駁口

Overall Dimensions

整體尺寸

:

Height 

  69.2 mm 

毫米

 (To Top Plate 

爐面

)

 

 

55  mm 

毫米

 (To Bench Top 

櫥檯面

)

 

 

95  mm 

毫米

 (To Pan Support 

爐架

)

Width 

  310  mm 

毫米

Depth 

 521.5 mm 

毫米

 (Body 

爐身

)

Weight 

:

5.5 kg 

千克

 (12.1 1b 

)

BENCHTOP CUT-OUT DIMENSIONS    

櫃面開孔尺寸

INSTALLATION    

安裝

* Install the built-in hob in a well ventilated room and keep it away from any combustible or infl ammable 

objects such as paper or oil.

 

爐須安裝在空氣流通之間 ,  附近不可放置易燃物品如紙張油類等

* Place the built-in hob on a stable and level bench top. Please refer to Fig. 2 for cut-out dimensions and 

position.

 

爐須放置在穩固及水平的櫃面 , 

 

請依照圖

2

 

示的開孔尺寸及置

268m

m

490

mm

600

mm

 (M

IN)

50m

m(

MI

N)

Ca

se 

by 

non

-in

fl a

mm

abl

e w

all

RB-11N-C.indd   Sec2:2

RB-11N-C.indd   Sec2:2

2/10/2009   9:12:12 AM

2/10/2009   9:12:12 AM

Содержание JZY-11N

Страница 1: ...OPERATING INSTRUCTIONS MODEL JZ Y T 11N MODEL RB 11N C CERAMIC GLASS TOP BUILT IN HOB NAGOYA JAPAN CORPORATION RB 11N C indd 1 RB 11N C indd 1 2 10 2009 9 12 09 AM 2 10 2009 9 12 09 AM...

Страница 2: ...e best condition please read the instructions below carefully COMPONENTS AND PARTS NAMES Front Side Gas Inlet Battery 1 5V 1 size C 1 5 1 C Pan Support Drip pan Top Plate Casing Air Intake Guard RB 11...

Страница 3: ...m Body Weight 5 5 kg 12 1 1b BENCHTOP CUT OUT DIMENSIONS INSTALLATION Install the built in hob in a well ventilated room and keep it away from any combustible or infl ammable objects such as paper or...

Страница 4: ...een two appliances is required with all gaps being sealed It is to avoid the infl uence of air draught on the operation of the built in hob when the oven fan is running In case that a partition plate...

Страница 5: ...esirable setting 4 Flame can be adjusted between MAX and MIN Please adjust fl ame slowly 5 If the fl ame is extinguished while using the Flame Failure Safety Device will shut the gas off after a short...

Страница 6: ...and mild detergent For burnt and stuck dirt wipe by cloth with liquid cream cleanser Top Plate Cleaning Do not use sharp edge tool like screwdriver and polishing powder in order to prevent scratch to...

Страница 7: ...fter fl ame is ignited 3 No main fl ame 3 1 Gas meter cock and or appliance cock have been turned off Open gas meter cock and or appliance isolating cock completely 3 2 Burner head is blocked by alumi...