background image

Rinnai Australia

9

Operation Manual

GENERAL WATER CONTROL INFORMATION

RADIO COMMUNICATIONS

Rinnai wireless water controllers are classified as short range radio communications devices and
referred to as Low Interference Potential Devices (LIPD’s) in AS/NZS 4268*. As such, they operate in
the same radio frequency spectrum as many other devices classified as LIPD’s such as garage door
openers and keyless automobile entry systems. Although interference with other LIPD's is unlikely, it
is not guaranteed interference will not occur.

Rinnai wireless water controllers must not be used in the vicinity of other devices if radio interference
with such devices could result in a dangerous situation, unless it is verified that interference will not
occur. Possible examples are medical devices and fire alarms.

*AS/NZS 4268 ‘Radio Equipment and systems – short range devices – Limits and methods of
measurement’.

WATER RESISTANCE

MAXIMUM DELIVERY TEMPERATURES

Rinnai continuous flow water heaters are factory pre-set to various maximum delivery temperatures
depending on model and their intended application. For the majority of applications, the factory pre-
set temperature is appropriate. In the unlikely event this is not the case this setting can be increased
or decreased by an authorised person such as a licensed plumber. 

Factory pre-set delivery temperatures for the various models are as follows:

Water controllers allow precise temperature control by the user. When used correctly, the hot water
unit will deliver the selected temperature, even when the water flow is varied, or more than one tap is
in use. Each remote controller can be individually programmed, however the water heater can only
deliver one set temperature at any time. The available temperatures (°C) are as follows:

Master Controller (used in kitchen):

37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50, 55°C* 60°C*, 65°C*, 75°C*

Bathroom Controller (used in bathrooms, ensuites, toilets and laundry):

Hot Water Delivery: 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 48, 50°C

Whilst hot water outlets are open the set temperature may be lowered. However the set temperature
cannot then be raised above 43°C. In addition transfer of 'priority' between controllers is not possible.
These are safety features.

The MC-503RC Wireless water controller is a water resistant device, however
excessive exposure to water such as immersion may result in damage to the
controller. 

• DO NOT immerse the controller into water. 
• AVOID direct exposure to water or steam as these conditions may cause a

malfunction. 

• ALWAYS AVOID exposure to water when the battery compartment is open.
• When cleaning your water controller use ONLY a damp cloth and a mild detergent. 

This does not apply to “50 degree compliant” models. To meet the regulatory
requirements the maximum delivery temperature is factory set and sealed.

MODEL NUMBER

MODEL NAME

FACTORY “PRE-SET”

MAXIMUM DELIVERY 

TEMPERATURE (°C)

CAN FACTORY “PRE-SET” 

MAXIMUM DELIVERY 

TEMPERATURE BE CHANGED 

BY AN AUTHORISED 

PERSON?

REU- VRM2626WD

INFINITY 26 Touch

60

Yes

REU- VRM2626WD-50

INFINITY 26 Touch

- 50°C Compliant

50

No

Note: The model number is written on the dataplate on the left hand side of appliance

NOTE

NOTE

Содержание infinity 26 touch REU-VRM2626WD

Страница 1: ......

Страница 2: ...This page is intentionally blank...

Страница 3: ...WATER CONTROLLER 15 ADJUSTING TEMPERATURE 15 HOW TO USE TWO OR MORE UNIVERSAL WATER CONTROLLERS 16 TRANSFERRING PRIORITY 16 ADJUSTING TEMPERATURE 16 DELUXE BATHROOM WATER CONTROLLERS 17 ABOUT THE DELU...

Страница 4: ...ontact the Plumbing Industry Commission on 1800 015 129 Heated water can be dangerous especially for young children and the infirm Water temperatures above 50 C can cause severe burns instantly and ma...

Страница 5: ...ain when the temperature falls below the selected temperature The burner lights automatically when the hot water tap is opened and goes out when the tap is closed IGNITION IS ELECTRONIC so there is no...

Страница 6: ...at the outlet There is no need to turn the water controller s off after use However if you prefer to turn the water controller s off selected temperatures to a maximum of 50 C will be stored in the s...

Страница 7: ...may discharged from the flue outlet This condition is normal for high efficiency appliances and does not indicate a fault Keep flammable materials spray cans fuel containers pool chemicals trees shrub...

Страница 8: ...disabled elderly and the infirm Hot water at 65 C a very common hot water temperature in Australia can severely burn a child in less than half a second At 50 C it takes five minutes ALWAYS Test the te...

Страница 9: ...tly the hot water unit will deliver the selected temperature even when the water flow is varied or more than one tap is in use Each remote controller can be individually programmed however the water h...

Страница 10: ...ter controllers allow temperature selection only Deluxe water controllers allow temperature selection have a clock function and on the Deluxe Bathroom water controller BC 100V a shower saver bath fill...

Страница 11: ...owered to a minimum of 37 C For safety it cannot then be raised above 43 C until all hot water taps are closed If the water heater is turned Off whilst hot water taps are open it can not be turned bac...

Страница 12: ...ssign the wireless transceiver if this is the case See UN ASSIGNING AND RESETTING WIRELESS WATER CONTROLLERS on page 36 and INSTALLING WIRELESS WATER CONTROLLERS on page 34 USING CHILD LOCK FUNCTION T...

Страница 13: ...er body Then turn the battery compartment cover a full turn clockwise to obtain the correct seal 5 Return the controller to the wall mounting bracket Use only 2 x 1 5V AAA alkaline batteries DO NOT mi...

Страница 14: ...tor and the In Use indicator will illuminate signifying that the preheat system has been activated 4 Wait approximately two minutes before opening an outlet This will allow the water in the pipework t...

Страница 15: ...may be lowered However they cannot then be raised above 43 C In addition transfer of priority between controllers is not possible These are safety features The beep sound can be muted by pressing the...

Страница 16: ...Use indicator will illuminate on the water controller Once the hot water is running if the set temperature is either too hot or cold press the Hot water temp or buttons until the desired temperature i...

Страница 17: ...E AT BUT TON Indicates the selected hot water temperature WATER TEM PER ATURE INDIC ATOR Indicates that the Shower Saver Bath Fill function has been selected and that a shower is running or the bath i...

Страница 18: ...normal mode press the Clock button once if no buttons are pressed for a period of approximately 60 seconds the controller will return to normal mode The time is always displayed regardless of whether...

Страница 19: ...ended period To select the volume of water to be used in the shower bath use the Water Volume or buttons The selected volume is displayed in large digits to the right and will remain as the default Wa...

Страница 20: ...Follow the voice prompt instructions When Shower Saver Bath Fill Operations Finishes Once the Shower Saver Bath Fill operation finishes the following events will occur 1 The flow from the shower bath...

Страница 21: ...controller is fitted press the Transfer button to transfer priority to the desired controller SETTING THE SOUND OPTIONS Voice prompts only available when Deluxe Bathroom water controller s are instal...

Страница 22: ...the water controller is turned ON or OFF The clock may need resetting if power to the water heater unit is disrupted due to a power failure or if the power is switched off over a prolonged period ADJU...

Страница 23: ...This will allow the water in the pipework to be warmed Other Controller Functions Controller functions such as temperature control and transfer of priority between multiple controllers is not affecte...

Страница 24: ...stance from transceiver or an obstruction Move wireless water controller or transceiver or remove the obstruction Noticeable reduction in water flow Inlet water filter needs to be cleaned Service call...

Страница 25: ...Rinnai Australia 25 Installation Manual NOTES...

Страница 26: ...Rinnai Australia 26 Operation Manual This page is intentionally blank...

Страница 27: ...ING WIRELESS WATER CONTROLLERS 34 WIRELESS WATER CONTROLLER INSTALLATION 35 INSTALLING MULTIPLE WIRELESS WATER CONTROLLERS 35 TROUBLE SHOOTING WIRELESS WATER CONTROLLERS CHANNEL ASSIGNMENT 36 UN ASSIG...

Страница 28: ...w and return system or the Rinnai Smartstart system can be used which minimise the waiting time for hot water delivery Alternatively multiple appliances can be strategically placed to serve outlets wi...

Страница 29: ...xceeding 50 C or your local regulations require installation with a Temperature Limiting Device then install the appliance in accordance with Diagram 2 page 29 Ensure that suitable fixing screws or bo...

Страница 30: ...fitted Master and Sub controllers and temperatures Only one wireless or wired controller can be designated the Master Controller MC This controller is normally used in the kitchen and usually has a ma...

Страница 31: ...nside the building Take the signal strength into consideration when determining the best location for both the transceiver and the wireless water controllers Other manufacturers water controllers are...

Страница 32: ...to 50 MJ hr input 150 Other appliances up to 50 MJ hr input 500 Appliances over 50 MJ h input and up to 150 MJ h input 1000 Appliances over 150 MJ h input 1500 1 Where dimensions c j or k cannot be ac...

Страница 33: ...ove does not apply when multiple Rinnai external water heaters of the same model are installed on the same vertical face with flue terminals at the same height Under these conditions appliances can ab...

Страница 34: ...1 Ensure the power to the water heater is switched on 2 Set the transceiver s maximum water temperature to 55 C by pressing the Max Temp button until 55 is displayed Refer to Master and Sub controlle...

Страница 35: ...and hold the On Off button until screen C is displayed This takes approximately 2 seconds 6 From screen C press the On Off button once to start the tuning process which will take approximately 5 secon...

Страница 36: ...ocedures to enable these options When installing combinations of both wired and wireless controllers all wired water controllers MUST BE connected before the wireless water controllers are assigned to...

Страница 37: ...ransceiver or when an object is obstructing the radio signal Wireless water controllers should be positioned such that the signal strength indicator displays at least 2 bars next to the antenna symbol...

Страница 38: ...water controller Feed any excess cable lengths into the wall cavity to avoid the pinching of cables between the wall and the controller As supplied the water heater is not pre wired for the installati...

Страница 39: ...ure for the fourth controller you may ignore Question 2 Fig 5 Fig 6 Is the water heater marked to state it delivers water not exceeding 50 C IF YES No further action required IF NO You will need to pr...

Страница 40: ...fixings as this may cause damage Once secured replace the face plate Fig 2 Fig 3 Fig 4 Fig 5 1 Determine the most suitable position for the water controller see notes page 38 2 Mark and drill 3 holes...

Страница 41: ...s clear especially on new installations 11 If water controllers are fitted it is necessary to test their operation through the complete range of functions refer to the Operation sections of this manua...

Страница 42: ...t can also assist the installer to identify potential installation errors that may prevent the appliance from operating correctly Recess Box These allow the appliance to be recessed into the cavity of...

Страница 43: ...Rinnai Australia 43 Installation Manual NOTES...

Страница 44: ...OIM INFINITY TOUCH 13 031 Issue 1 05 02 14 44 CONTACT INFORMATION...

Отзывы: