- 24 - 

OPERATION WITH DELUXE TEMPERATURE CONTROLLERS 

  

 
(b) Select the desired temperature using the ÔBath temp.Õ buttons 

located behind the flip panel.  The selected temperature will be 
displayed on the bottom of the bathroom controller monitor and 
will remain until it is next changed.   

 

(c) Select the desired bath volume using the ÔWater Vol.Õ Buttons 

located behind the flip panel.  The selected volume will be 
displayed at the bottom of the bathroom controller monitor 
numerically, and graphically by the long bar against the level 
markers.  During the first bath fill, it is recommended that the 
lowest bath fill volume of 100 litres is used.  During subsequent 
bath fills this can be increased depending on the volume of your 
bath and the desired level. 

 
The relationship between bath volume in litres and the position of the long bar against the level 
markers is as follows. 
 
Eg.  120 litres Ð denoted numerically and by the second level marker from the bottom of the 

monitor, as shown below. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
(d) After approx. 5 seconds, the numeric volume 

displayed will revert to the bath fill temperature 
previously set.  The long bar on the level markers 
will remain. 

 

Remember that the bath 
level markers on the 
display are not a true 
representation of your bath. 
ie. the Ôhalf-wayÕ mark on 
the monitor is not 
necessarily the Ôhalf-wayÕ   

mark on your  bath. 
The average bath size 
is 160 litres.   
Be careful not to 
overfill the bath! 

NOTE

Volume (L)

Position of 

long bar

350

300

280

260

240

220

200

400

180

160

140

120

100

12

11

10

9

8

7

6

12

5

4

3

2

1

Sound 

ON/OFF

Transfer

Bath temp.

Water Vol.

C

C

Bath Fill

Hot water temp.

Vol.

BC - 70 - 1A

 

Sound 

ON/OFF

Transfer

Bath temp.

Water Vol.

C

C

Bath Fill

Hot water temp.

Vol.

BC - 70 - 1A

 

Sound 

ON/OFF

Transfer

Bath temp.

Water Vol.

C

C

Bath Fill

Hot water temp.

Vol.

BC - 70 - 1A

 

Содержание infinity 18

Страница 1: ...Infinity 18 Infinity 20 Infinity 22 Infinity 24 Infinity 32 Your installer is responsible for correct installation Installation instructions are located in a pouch attached to the inside front panel o...

Страница 2: ...AS3000 Local Water Authority Regulations Local Gas Fitting Regulations Municipal Building Codes AS5601 AG601 Gas Installations Any other relevant Statutory Regulations This Infinity must be installed...

Страница 3: ...rs 12 Deluxe Temperature Controllers 15 Deluxe Kitchen Temperature Controller 15 Deluxe Kitchen Temperature Controller Monitor 16 Deluxe Bathroom Temperature Controller 17 Deluxe Bathroom Temperature...

Страница 4: ...hot water is CONSTANTLY MONITORED by a BUILT IN SENSOR If the temperature of the outgoing hot water rises to more than 3 C above the selected temperature shown on the Digital Monitor or the pre set l...

Страница 5: ...water tap may vary after the selected temperature at the Temperature Controller is altered The water flow may also vary from summer to winter as incoming water temperatures differ If freezing conditi...

Страница 6: ...utton on the Kitchen Controller after having transferred priority of temperature selection to the Bathroom Controller as the system will no longer heat the water Turn OFF then ON WARNING Someone may b...

Страница 7: ...in the bathroom Take the phone off the hook Do take them out of the bathroom if you need to answer the phone or door Do test the temperature of the water with your elbow before placing your child in t...

Страница 8: ...nic ignition and the flame extinguishes as soon as water flowing through the appliance stops Simply open a hot water tap The Infinity is factory pre set to 55 C If you require greater control over the...

Страница 9: ...erature will become 43 C This provides additional safety for the consumer Suggested temperatures are Kitchen 50 C Shower 42 C Bath fill 40 C These temperatures are suggested starting points for select...

Страница 10: ...e this control in installations where only one controller is required H O T T E R O N O F F C O O L ER APPROX WATER TEMP TEMPERATURE CONTROL MC 33 3A ON IN USE oC DIGITAL MONITOR Indicates the tempera...

Страница 11: ...O F F C O O L ER TEMPERATURE CONTROL ON APPROX WATER TEMP oC BC 45 3A IN USE R A NS F E T R DIGITAL MONITOR Indicates the temperature selected Error code flashes in the event of a fault TRANSFER Alte...

Страница 12: ...ll automatically light the burner providing hot water The red IN USE indicator will glow on the Temperature Controller Adjusting Temperature Simply press the HOTTER or COOLER button until the required...

Страница 13: ...Temperature Controllers See page 11 for details on operating and adjusting water temperature with the Temperature Controllers Each Temperature Controller is capable of storing a separate temperature s...

Страница 14: ...can now be selected using the Bathroom Controller The maximum temperature which can be selected at the Bathroom Controller is 50 C whilst there is no water running This is to help reduce the risk of...

Страница 15: ...ly Temperature selection cannot be transferred Water temperature can only be adjusted between 37 C and 43 C The Kitchen and Bathroom Control cannot be turned ON O N O F F ON The temperature of outgoin...

Страница 16: ...temperature controllers CLOCK BUTTON Used to select the clock function HOUR MIN BUTTONS Used to select the hours and minutes of the clock Clock Hour Min Vol Bath C AM L Hot water temp 00 00 ON OFF MC...

Страница 17: ...COMBUSTION INDICATOR Red Shows when hot water is used ERROR INDICATOR Flashes an error code if there is a fault CLOCK Each time a button is pressed a beep will sound The beep sound and the bath fill...

Страница 18: ...TH TEMP BUTTONS Used to select bath fill temperature WATER VOLUME BUTTONS Used to select bath fill volume Sound ON OFF Transfer Bath temp Water Vol C C Bath Fill Hot water temp Vol BC 70 1A DIGITAL MO...

Страница 19: ...water still needs to flow for the bath to be filled to the selected volume decreases as bath fills WATER LEVEL INDICATOR Indicates bath fill volume selected BATH TEMP INDICATOR Indicates bath fill te...

Страница 20: ...ur and Min buttons The time is displayed on the monitor as the buttons are pressed The numbers on the monitor will continuously change if you keep the buttons depressed When you get close to the desir...

Страница 21: ...on behind the flip panel once The Transfer button will light up Select the desired temperature using the Hot water temp buttons The selected temperature will be displayed on the controller monitor Ope...

Страница 22: ...the monitor will continuously change if you keep the buttons depressed When you get close to the desired time press the button intermittently Press the C lock but ton again to activate the clock Cloc...

Страница 23: ...When the system is ON the monitors will be lit Ensure the Transfer button is lit If not press the Transfer button once Select the desired temperature using the Hot water temp buttons The selected tem...

Страница 24: ...unction and follow the voice prompts Step 1 Programming the bath volume and temperature When the controllers are first turned on the default bath fill temperature is 40o C and the bath volume is 100 l...

Страница 25: ...in litres and the position of the long bar against the level markers is as follows Eg 120 litres denoted numericallyand by the second level marker from the bottom of the monitor as shown below d After...

Страница 26: ...ll stop the Bath fill button on the Bathroom Controller s and the Bath indicator on the Kitchen Controller monitor will flash the buzzer will sound the voice will say Bath fill is complete Turn off th...

Страница 27: ...room Controllers BC 70 1A BSC 45 3A See pages 22 to 23 and page 11 for details on setting the hot water delivery temperature for the Kitchen and Bathroom Controllers Bath Fill Function The Bath fill f...

Страница 28: ...setting the hot water delivery temperature for the Kitchen and Bathroom Controllers Bath Fill Function See pages 23 to 25 for details on the bath fill function With two Bathroom Controllers fitted one...

Страница 29: ...duction in water flow Inlet water filter needs to be cleaned Service call 03 Power interruption during Bath fill water will not flow on power reinstatement Turn off all hot water taps Press ON OFF twi...

Страница 30: ...uality plumbing fittings and other outside influences are not the responsibility of Rinnai Australia and service calls for these issues will be charged for The recommended water quality levels are as...

Отзывы: