Care of your iHeat

Your iHeat system needs very little maintenance, however the following information will keep it 
working efficiently.

Cleaning the return air filter

Your iHeat system has a large 
return air grille through which air  
is returned to the iHeat for 
reheating. The return air grille 
contains a filter that traps dust 
and other particles from the air. 
This needs to be cleaned regularly 
(every 2-4 weeks). If this is not 
done you may notice increased 
noise at the return air grille.

To clean the return air filter:

1.  Remove filter from return air 

grille housing. 

 
 
 
 
 
 
 
 
 

2.  Clean any dust or debris from 

both sides of the filter using 
a vacuum cleaner, a soft dry 
cloth, or a soft brush. Do this 
on a flat surface to stop the 
frame from bending out of 
shape. 

3.  If required, wipe down the 

return air grille using a damp 
cloth. 

4.  Return the filter to the return 

air grille and secure the grille 
in place.

Cleaning the Rinnai Infinity 
water filter

Cleaning the Infinity 
water filter will reduce the 
likelihood of blockages 
to the water heater which 
could cause insufficient 
water flow to the iHeat. 

It is recommended the water filter 
is cleaned every year. This would 
normally be completed by a Rinnai 
Service Centre as part of annual 
servicing, but could be needed 
inbetween times if you experience 
any problems with insufficient 
water flow to the pump.

To avoid burns wait until 
the water heater cools 
before cleaning the water 

filter as hot water may drain from 
the unit if there has been recent 
hot water use. Turn off the gas and 
power to the Infinity.

1.  Unscrew the water filter from 

the position marked in the 
diagrams below.

2.  Flush the filter using clean 

water. 

3.  Replace the water filter. 

4.  Turn on the gas and power to 

the unit.

Maintenance and servicing

Rinnai has a 
maintenance, 
service, and spare 
parts network with 
personnel who are fully 
trained and equipped 

to give you the best advice on your 
Rinnai iHeat system.

If your system needs maintenance 
and/or servicing, please call Rinnai 
(0800 746 624) from a land line 
and select option one for a service 
centre in your area.

For reliable operation the Rinnai 
iHeat and Rinnai Infinity unit 
should be serviced annually. 
Regular maintenance and servicing 
is not covered by the Rinnai 
warranty.

Do not attempt to carry out any 
work on your system other than 
that mentioned in this guide. If 
you have any faults or problems, 
contact your installer, or call 
Rinnai.

WARNING

Содержание iHeat

Страница 1: ...iHeat Operation guide Combined water and central heating system ...

Страница 2: ...future reference Warning Improper installation adjustment alteration service or maintenance can cause property damage personal injury or loss of life For more information about buying living and servicing of Rinnai appliances call 0800 RINNAI 0800 746 624 Rinnai New Zealand Limited 105 Pavilion Drive Mangere Auckland PO Box 53177 Auckland Airport Auckland 2150 Phone 09 257 3800 Fax 09 257 3899 Ema...

Страница 3: ...Heat thermostat 5 Operating in manual mode 6 Operating in timer mode 7 Fan settings 9 Care of your iHeat 10 Advanced settings 11 Safety 12 Troubleshooting 13 General information 15 Installation checklist 16 Installer details 16 Limited warranty 18 ...

Страница 4: ...eating area up to 250 m depending on where you live and how well insulated your house is Efficiency delivers heat at the same efficiency as the Rinnai Infinity Noise level of fan sounds like an air conditioning unit The Rinnai Infinity provides hot water to the iHeat air handler unit heat exchanger The heat exchanger extracts the heat from the hot water and transfers it to a steady stream of air T...

Страница 5: ...allways regular accessed doorways etc hot spots direct sunlight above fireplaces heaters etc dead spots where the air does not circulate freely alcoves corners behind doors etc LCD screen Important The thermostat has an LCD screen Sharp instruments like a pen or pencil can damage the thermostat Batteries The thermostat comes with two AA alkaline batteries installed When the batteries are running l...

Страница 6: ...ng on and off Fan adjusting the fan to lo med hi or auto Set temperature adjusting the set temperature up or down Clock adjusting the time Turning the system on 1 Press System and use the up and down arrows until Heat is flashing 2 Press Done to save Turning the system off 1 Press System and use the up and down arrows until Off is flashing 2 Press Done to save Changing the fan setting Refer to pag...

Страница 7: ...ome of the steps below without changing anything Once comfortable with how the display works you can change the respective settings to suit Ignore any settings relating to cooling by selecting Next these have no effect on the iHeat operation this only appears as the thermostat is also used for other applications 1 Press More 2 Press Schedule 3 Press Edit 4 Use the up and down keys to change the fl...

Страница 8: ...ess Override The override settings will default to those contained in the next occupied period 2 Use the up and down keys to change the override time and temperature 3 Press Done to save the setting 4 Override will continuously flash on the screen to indicate the thermostat is in Override mode 5 To revert back to the set timers press Cancel or wait until the Hold Until time has been reached Holida...

Страница 9: ...on high Changing the fan setting 1 Press System Fan 2 Press Fan 3 The current setting will flash use the up down keys to shift between Lo Med Hi and Auto modes 4 Press Done to save the setting Changing the fan to circulate air on a hot day If you want air to circulate through the house on a hot day do the following 1 Press System Fan 2 Use the up down keys to toggle between Heat and Off select the...

Страница 10: ...eat It is recommended the water filter is cleaned every year This would normally be completed by a Rinnai Service Centre as part of annual servicing but could be needed inbetween times if you experience any problems with insufficient water flow to the pump To avoid burns wait until the water heater cools before cleaning the water filter as hot water may drain from the unit if there has been recent...

Страница 11: ... off US only 0540 Number of programmable periods per day 0640 Time format 0120 First two digits of current calendar year To change the current setting use the up down keys Options are 20 for years 20xx 21 for years 21xx 0130 Last two digits of current calendar year To change the current setting use the up down keys Options are 01 through 99 for example 2012 would be set to 12 0140 Current calendar...

Страница 12: ...s damaged the system must not be modified Switch off the power and unplug the iHeat before touching any wiring Children should be supervised at all times to ensure they do not play with any part of the system Do not touch any damaged electrical component If any electrical wiring is damaged it must be replaced by a licensed tradesperson To avoid burns turn off the gas and power to the Infinity befo...

Страница 13: ...f air is in the heating circuit Operate easing gear on the pressure relief valve for two minutes p 14 Make sure the gas power and water has been turned off to the Infinity and that a drain line has been fitted Water drips from the pressure relief valve Service call Water drips from the iHeat overflow Leak in iHeat unit Service call iHeat pump operates for no reason Biosafe operation p 15 If operat...

Страница 14: ... fixed by operating the easing gear on the pressure relief valve for approximately two minutes To avoid burns water can come out of the unit at 75 C wait until the water heater cools as hot water may drain from the unit if there has been recent hot water use Turn off the gas and power to the Infinity The pressure relief valve of the iHeat is located in between the Rinnai Infinity piping as shown b...

Страница 15: ...n which runs the pump for two minutes every week after a week of inactivity to kill any bugs in the water The timing of this operation will depend on when the unit was connected to power For example if this occurred at 4pm the biosafe operation will operate at 4pm If you experience a power cut in the middle of the night the biosafe operation will revert to the time that the power was restored If t...

Страница 16: ...also instruct you about the use and care of the appliance and ensure you understand the safety instructions and operation of the appliance Before the installer leaves ensure they leave the commissioning sheet with you This is important as it demonstrates they have installed the system in accordance with our instructions Installer details Company name Installer name Address Phone Mobile Signed Date...

Страница 17: ...Rinnai iHeat Warranty ...

Страница 18: ...n sited in accordance with the installation instructions or installed such that normal service access is difficult a service charge will apply If at the discretion of the attending service person the installation is deemed illegal or access is dangerous service will be refused Any work required to gain access to the appliance will be chargeable by the attending service person for example removal o...

Страница 19: ...he water supply Some examples of water quality issues where water may need to be treated Hard water areas including Wanganui Aggressive water areas including Christchurch Both hard and aggressive water some bore water Other continuous flow water heaters connected to the Rinnai iHeat The Rinnai iHeat system has been designed and tested for optimum performance with a Rinnai Infinity continuous flow ...

Страница 20: ...Rinnai co nz Experience our innovation 0800 746 624 http www youtube com rinnainz ...

Отзывы: