WARNING
REFRIGERANT
This appliance uses R32 (difluoromethane) refrigerant, which is a flammable gas class 2.2
according to AS 1677 and must be handled by a refrigeration mechanic with appropriate Australian
refrigerant handling licence.
WARNING
Risk of fire / flammable material. If the refrigerant is leaked, together with an
external ignition source, there is a possibility of ignition.
Read the OPERATING INSTRUCTIONS carefully before operation.
Service personnel are required to carefully read the OPERATING INSTRUCTIONS and
INSTALLATION MANUAL before operation.
Further information is available in the OPERATING INSTRUCTIONS, INSTALLATION
MANUAL, and the like.
Certain levels of refrigerant require minimum room sizes. Please ensure that these minimum
room sizes are adhered to for standard installations (up to 10m pipe length). If larger refrigerant
charges than standard are used then please consult AS/NZS 60335.2.40 to determine the safe
minimum floor area for the installation.
Make sure that the area has been made safe by having suitable ventilation and is free from ignition
sources before charging or releasing the charge of R32.
Model
HSNRP26 HSNRP35 HSNRP50 HSNRP60
HSNRP70
HSNRP80
Standard Charge (g)
900
900
1260
1260
1400
1400
Minimum Floor Area (m
2
)
4.0
4.0
4.0
4.0
4.0
4.0
WARNINGS AND IMPORTANT INFORMATION