Test operation and lighting sequence
It may take approximately two hours of operation for the burn media to achieve
their full flame pattern and glow. During the initial burning in period, some smoke
and smell may be experienced. The appliance should run on the high setting in a
well ventilated room until these dissipate. It is important to check the flame pattern
during this time.
Abnormal flame pattern
Abnormal flame performance and/or pattern
can indicate a problem with your fire, such as
blocked gas injectors, or that the burn media
has shifted. There are some warning signs that
could indicate a problem.
-
Unusual smell from the appliance
-
Continued difficulty or delay in establishing
a flame
-
Flame appears either very short or very
long
-
Flame only burns part way across the
burner
-
Severe soot building up on the inside of the
glass door
Important
It is the responsibility of the installer to check
that under normal conditions of the appliance,
all flue gases are exhausted to the outside
atmosphere, and that there is no spillage of
combustion gases into the room.
If the appliance cannot be made to perform
correctly please contact Rinnai.
Installation checklist and customer handover
Complete the installation checklist in the customer operation guide, and make sure you leave the
guide with the customer. Explain to the customer about the use and care of the unit, and ensure
they understand the instructions and operation of the appliance.