16
| Evolve 952/1252 Installation Guide: 13115-E 05-19
Install heater into enclosure
1. Carefully move the heater into the enclosure, guiding the piping, flexible gas connection, and
telescopic extension tube into the access openings and through the appliance. Ensure that the
air hose is not in a position where it could get caught or crushed by the unit.
2. Once the engine is in place reconnect the flue exhaust to the telescopic extension tube and
secure together with the pipe clamp.
3. Secure the heater flange in place using 11 screws (seismic constraint).
4. Complete gas, air hose, and flue connection. If vertically flueing ensure condensate tube,
provided with the EVOKIT03 flue kit, is attached to the condensate pipe on the heater—
refer
images below.
Please note
: The unit is supplied with the heater condensate already connected.
Flue locking clamp
Telescopic extension tube
Flue exhaust
Flange screw position—11 in total
Flue condensate pipe connection
The engine comes with the heater condensate already connected.