100000354
KB Series Electrical Diagnostic Points
RU80i/e, RU98i/e
Heat Exchanger, Outgoing Water Temperature and
Inlet Thermistors:
Check all thermistors by inserting meter leads into each
end of the thermistor plug. Set your meter to the 20 K
scale and read resistance. Applying heat to the
thermistor bulb should decrease the resistance. Apply-
ing ice to the thermistor bulb should increase the
resistance. See below for examples of typical
temperatures and resistance readings.
*Example:
140°F = 2.2 ~ 2.7K
221°F = 0.6 ~ 0.8K
59°F = 11.4 ~ 14K
86°F = 6.4 ~ 7.8K
113°F = 3.6 ~ 4.5K
Flame Rod:
Place one lead of your meter to the flame rod and the
other to ground. With the unit running you should read
between 5
-
150 VAC. Set your meter to the μ amp scale
and series your meter in line with the flame rod. You
should read 1 μ amp or greater for proper flame circuit.
In the event of low flame circuit remove the flame rod
and check for carbon or damage.
Frost Protection:
This unit has frost protection heaters mounted at
different points to protect the water heater from freezing.
All of them should show a positive resistance reading.
Amp Fuses:
This unit has one inline (10) amp glass fuse. Remove
the fuse and\ check continuity through it. If you have
continuity through the fuse then it is good. Otherwise the
fuse is blown and must be replaced.
Wire Color
Voltage
Resistance
Connector #
Pin #’s
(Main) Black
-
Pink
11 ~ 13 VDC
24 ~ 28 ohms
B1
3
-
4
(SV1) Black
-
Blue
11 ~ 13 VDC
35 ~ 41 ohms
B3
4
-
6
(SV2) Black
-
Yellow
11 ~ 13 VDC
35 ~ 41 ohms
B2
4
-
7
(SV3) Black
-
Red
11 ~ 13 VDC
39 ~ 42 ohms
B4
4
-
5
(POV) Yellow
-
Yellow
2 ~ 15 VDC
67 ~ 81 ohms
D4
1
-
2
(SV1, SV2, SV3 and POV) Gas valve and Modulating solenoids: (Set meter below 2K)
Red
-
Pink
5 ~ 8 VDC
24 ~ 28 ohms
G2
3
-
4
White
-
Blue
5 ~ 8 VDC
35 ~ 41 ohms
G2
1
-
2
Grey
-
Brown
N/A
N/A
G2
5
-
7
Grey
-
Orange
N/A
N/A
G2
6
-
7
(M) Water Flow Control Device Servo or Geared Motor:
NOTE: The grey wire listed above turns to black at G connector on the PCB.
Содержание Circ-Logic RU80e
Страница 16: ...Condensing Water Heater Service Manual 16 100000354 KA Series Wiring Diagram RC80HPe RC80HPi ...
Страница 17: ...Condensing Water Heater Service Manual 17 100000354 KA Series Wiring Diagram RC98HPe RC98HPi ...
Страница 18: ...Condensing Water Heater Service Manual 18 100000354 KB Series Wiring Diagram RU80i e RU98i e ...
Страница 57: ...Condensing Water Heater Service Manual 57 100000354 Notes ...
Страница 58: ...Condensing Water Heater Service Manual 58 100000354 Notes ...
Страница 59: ...Condensing Water Heater Service Manual 59 100000354 Notes ...