Condensing Water Heater Service Manual
11
100000354
COMPONENT
MEASUREMENT POINT
RANGE OF VALUE
CN
PINS
WIRE COLOR
WATER FLOW SENSOR
E5
1
-
3
R
-
Bk
DC11
-
13V
2
-
3
Y
-
Bk
DC4
-
7V; 1
-
1.4 MΩ
BYPASS FLOW CONTROL
G1
1
-
5
Br
-
W
DC2
-
6V DURING OPERATION
15
-
35 Ω
2
-
5
O
-
W
3
-
5
Y
-
W
4
-
5
R
-
W
WATER FLOW CONTROL
G2
3 or 4
-
8
R or P
-
O
DC5
-
7V DURING OPERATION
1 or 2
-
8
B or W
-
O
3
-
4
R
-
P
30
-
50 Ω
1
-
2
B
-
W
7
-
5
Y
-
Gy
BELOW DC1V (LIMITER ON)
DC0
-
6 (LIMITER OFF)
7
-
6
Br
-
Gy
COMBUSTION FAN
L1
1
-
2
R
-
Bk
DC6
-
45V
2
-
3
Y
-
Bk
DC11
-
13V; 3.5
-
3.9 k
Ω
2
-
4
W
-
Bk
DC5
-
10V; 9.2
-
9.4 k
Ω;
(PULSE 20
-
420 Hz)
KA Series Electrical Diagnostic Points
RC80HPe, RC80HPi
Содержание Circ-Logic RU80e
Страница 16: ...Condensing Water Heater Service Manual 16 100000354 KA Series Wiring Diagram RC80HPe RC80HPi ...
Страница 17: ...Condensing Water Heater Service Manual 17 100000354 KA Series Wiring Diagram RC98HPe RC98HPi ...
Страница 18: ...Condensing Water Heater Service Manual 18 100000354 KB Series Wiring Diagram RU80i e RU98i e ...
Страница 57: ...Condensing Water Heater Service Manual 57 100000354 Notes ...
Страница 58: ...Condensing Water Heater Service Manual 58 100000354 Notes ...