Some error codes that may be encountered during installation are detailed in Table 8 below.
Table 8. Error codes associated with installation
Fault Code
Primary L.E.D 1
Flashes
Primary L.E.D 2
Flashes
Description
30
3
0
Fan Limp Mode
35
3
5
Supply Air Thermistor Fault
36
3
6
Bad Supply Air Thermistor Location
40
4
0
Return Air Overheat
41
4
1
Supply Air Overheat
48
4
8
Pressure Lost
60
6
0
Motor Open Circuit
69
6
9
Fuse Blown 24Vac 2A
50
5
0
Ignition Lockout
51
5
1
Rollout No Gas
54
5
4
Rollout Lockout
56
5
6
Pressure Switch Stuck Open
57
5
7
Pressure Switch Stuck Closed
58
5
8
Pressure Switch Fail
To reset the appliance and clear a lockout fault press and hold the ‘CLEAR’ button for three seconds on the heater