Rimage Professional™ 3400 and 5400N Diagnostic Tests
2001497_A
11
Test 5 – Cycle Carousel Test Diagnostic
This test continuously cycles the carousel between bins 1 and 3.
1.
Make sure the autoloader is in diagnostic test mode. Refer to the
Access and Select Diagnostic Tests
section on page 1.
2.
Press
button 1
five times and hold it until the operator panel displays
[INDEX: XXXXX CYCLE = XXXXX]
.
Tip:
INDEX: XXXXX is the top carousel rotation speed. CYCLE = XXXXX is the number of cycles
completed.
3.
Release
button 1
. The test starts automatically.
•
The carousel rotates back and forth between bins 1 and 3.
•
The cycle count
[CYCLE = XXXXX]
advances with each rotation.
Note:
The autoloader continues to cycle the carousel until you press button 1 to stop the test.
4.
Press
button 1
to stop the test and return to diagnostic test mode. The operator panel displays
[00 CHOOSE DIAGNOSTIC]
.
Test 6 – Cycle Lift Test Diagnostic
This test continuously cycles the lift arm in and out of bin 1.
1.
Make sure the autoloader is in diagnostic test mode. Refer to the
Access and Select Diagnostic Tests
section on page 1.
2.
Press
button 1
six times and hold it until the operator panel displays
[INDEX: XXXXX CYCLE = XXXXX]
.
Tip:
INDEX: XXXXX is the top lift arm speed. CYCLE = XXXXX is the number of cycles completed.
3.
Release
button 1
. The test starts automatically.
•
The lift arm moves in and out of carousel bin 1.
•
The cycle count
[CYCLE = XXXXX]
advances with each carousel rotation.
Note:
The autoloader continues to cycle the lift arm until you press button 1 to stop the test.
4.
Press
button 1
to stop the test and return to diagnostic test mode. The operator panel displays
[00 CHOOSE DIAGNOSTIC]
.
Test 7 – Currents Test Diagnostic
This test sets the current values for the lift arm and the carousel.
1.
Make sure the autoloader is in diagnostic test mode. Refer to the
Access and Select Diagnostic Tests
section on page 1.
2.
Press
button 1
seven times and hold it until the operator panel displays
[07 TEST CURRENTS 100%
].
3.
Release
button 1
.
4.
Press
button 1
to toggle between the two current values. The operator panel displays
[07 TEST CURRENTS
100%]
and
[07 TEST CURRENTS 80%]
.
5.
Press and hold
button 1
to save the 80% or 100% value and exit the test. The autoloader returns to
diagnostic test mode and the operator panel displays
[00 CHOOSE DIAGNOSTIC]
.
Note:
The current values are used for all motions while the autoloader is in diagnostic test mode as
well as normal operation mode. The values are stored in temporary memory. The 100% value will be
used after the autoloader has been powered off.