Diagnostic Tests for the Rimage Professional™ 3400 and 5400N
8
2001497_A
Test 4 – Sensors Test Diagnostic
This test verifies the functionality of the motion detectors and sensors in the 3400 and 5400N. There are 2
motion detectors and 5 sensors and in the autoloader.
When diagnostic test 4 has been selected, the operator panel displays the following screen:
•
Each letter on the bottom row of the screen stands for a motion detector or sensor:
LM:
Lift motion detector
located inside the left arm
CM:
Carousel motion detector
located inside the carousel
D:
Door sensor
located on the front of the autoloader frame
G:
Gripper plunger sensor
located inside the lift arm
O:
Output bin sensor
located inside the output bin, on the left side of the autoloader
L:
Lift home sensor
located at the top of the lift column, inside the autoloader
C:
Carousel home sensor
located beneath the carousel
•
The top row of the screen displays the status of the motion detectors and sensors during each test:
X X:
Indicates the various
digital values
for the lift motion and carousel motion detectors.
Note:
These digital values change continuously while the lift arm and carousel are in motion.
0:
Indicates that the sensor path is clear or the switch is closed.
1:
Indicates that the sensor path is interrupted or the switch is open.
Select Diagnostic Test 4
1.
Remove all
discs
from the autoloader. Make sure the printer tray, recorder trays, carousel, and output bin
are empty.
2.
Make sure the autoloader is in diagnostic test mode. Refer to the
Access and Select Diagnostic Tests
section on page 1.
3.
Press
button 1
four times and hold it until the following screen displays on the operator panel:
4.
Release
button 1
.
5.
Follow the instructions on
for the motion detector or sensor that you wish to test.
Note:
When you are finished with diagnostic test 4, press button 1 once to exit the test and return to
diagnostic test mode. The operator panel displays
[00 CHOOSE DIAGNOSTIC]
.
X X
X X
0 1 1 1 1
L M C M D G O L C
X X
X X
0 1 1 1 1
L M C M D G O L C