Rimage Professional™ 3400 and 5400N 

Diagnostic Tests  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание Professional 3400

Страница 1: ...Rimage Professional 3400 and 5400N Diagnostic Tests...

Страница 2: ...a Disc at the Recorder 4 Cycle 3 Cycle a Disc between the Recorder and the Printer 4 Cycle 4 Cycle Discs at the Carousel 5 Cycle 5 Cycle Discs between the Carousel and the Printer 5 Cycle 6 Cycle the...

Страница 3: ...GNOSTIC displays on the operator panel Note Other status messages display on the operator panel while button 1 is being held in Do not release the button until the operator panel displays 00 CHOOSE DI...

Страница 4: ...s Test 1 Solenoid Test Diagnostic This test cycles the solenoid in the lift arm 1 Make sure the autoloader is in diagnostic test mode Refer to the Access and Select Diagnostic Tests section on page 1...

Страница 5: ...the devices are set up for a cycle press and hold button 1 to display an option menu on the operator panel Each option displays for 3 seconds Release button 1 while an option is displayed to select th...

Страница 6: ...e recorder tray 8 Repeat steps 1 7 for the second recorder tray Cycle 3 Cycle a Disc between the Recorder and the Printer 1 Select diagnostic test 2 Refer to page 3 2 Press button 2 to open the printe...

Страница 7: ...IC 6 Remove the discs from the carousel and the output bin Cycle 5 Cycle Discs between the Carousel and the Printer 1 Select diagnostic test 2 Refer to page 3 2 Select diagnostic test 2 The operator p...

Страница 8: ...te When diagnostic test 3 is complete the autoloader automatically exits the test and returns to diagnostic test mode 1 Make sure the autoloader is in diagnostic test mode Refer to the Access and Sele...

Страница 9: ...he autoloader automatically begins to take the following measurements Carousel bin top measurement The autoloader measures the distance between the top of the lift column and the top edge of the carou...

Страница 10: ...s the status of the motion detectors and sensors during each test X X Indicates the various digital values for the lift motion and carousel motion detectors Note These digital values change continuous...

Страница 11: ...e lift arm is in motion Door Sensor D The door sensor is located on the right side of the control panel on the front of the autoloader It detects when the front door is open and closed 1 Close the fro...

Страница 12: ...ually move the lift arm away from the top of the lift column The operator panel displays 2 Move the lift arm to the top of the lift column The operator panel displays Carousel Home Sensor C The carous...

Страница 13: ...XX CYCLE XXXXX Tip INDEX XXXXX is the top lift arm speed CYCLE XXXXX is the number of cycles completed 3 Release button 1 The test starts automatically The lift arm moves in and out of carousel bin 1...

Страница 14: ...unctional and technical description of the problem Exact error message received Contact Rimage Europe Rimage Corporation reserves the right to make improvements to the equipment and software described...