18
2001475_A
Rimage Producer™ III User Guide
7100N/8100N/6100N/6100
6.
Manually, slowly move the
lift arm
and
disc
down into the bin. Make sure that the disc does not interfere with the
carousel as it moves into the bin.
-
Important!
If the disc interferes with the carousel in step 7, the lift arm may be miscalibrated or there may be an
issue with the hardware that positions the carousel. Perform diagnostic test 3 (Calibrate Diagnostic Test) on page 18
to calibrate the lift arm and the carousel.
7.
Manually move the
lift arm
out of the bin.
8.
Repeat
steps 6 - 8
for the remaining bins.
9.
Press the
disc release button
to release the disc and remove it from the lift arm.
10.
Press and hold the
operator button
to exit the test and return to diagnostic mode.
11.
Refer to the
Exit Diagnostic Mode
section on page 17 to exit diagnostic mode.
Diagnostic Test 3 – Calibrate Diagnostic Test
This test has two modes. The first mode calibrates the lift arm to accurately detect the number of discs in the carousel bins.
The second mode calibrates the carousel.
-
Important!
If you are updating the autoloader firmware, you must prompt the system to run the carousel calibration
test immediately after the lift arm calibration test.
Calibrate the Lift Arm
This test calibrates the lift arm to accurately detect the number of discs in the carousel bins.
1.
Remove all
discs
from the carousel bins.
2.
Make sure that the autoloader is in diagnostic mode. Refer to the
Access and Select Diagnostic Tests
section on page 16.
3.
Press the
operator button
three times and hold on the third press until the operator panel displays [03 CALIBRATE].
4.
Release the
operator button
. The lift arm moves to the top position and the light on the operator button flashes.
-
Important!
• If you are updating the autoloader firmware, you must prompt the system to run the carousel calibration test
immediately after the lift arm calibration test. Move the lift arm to the top of the lift column at this time and
then continue to step 5.
• If you want to proceed with the lift arm calibration test only, continue to step 5 at this time.
5.
Place one
disc
in bin 1.
-
Important!
Place only one disc in bin 1.
Tip:
If you need to rotate the carousel to load media into bin 1, rotate it manually. Pressing the operator button
prompts diagnostic test 3 to begin.
En
gli
sh
Содержание Producer III 6100
Страница 100: ...Rimage Producer IIIN 8100N 7100N 6100N 6100 Rimage Everest III Rimage Producer III...
Страница 109: ...9 2001475_A Producer III Producer III PC 6100N 6100 6100N 8100N 8100N PC 7100N 8100N...
Страница 110: ...10 2001475_A Rimage Producer III 7100N 8100N 6100N 6100 7100N 8100N 6100N USB 6100...
Страница 111: ...11 2001475_A Producer III Producer III 2 Producer IIIN PC 25 Gemini Rimage 1 6100 6100N 8100N Producer III PC 25...
Страница 113: ...14 2001475_A Rimage Producer III 7100N 8100N 6100N 6100 1 2 Producer III a b 3 1 2 3...
Страница 114: ...15 2001475_A Producer III 1 100 1 2 3 100 1 4 4 2 3 5 1 2 3 4 2 3 5 Producer III...
Страница 121: ...23 2001475_A Producer III b i ii iii c 7 8 9 10 Everest 1 6mm 0 063 Prism 0 25 0 38 mm 0 010 0 015...