4 How to Use
4-4. How to install
GD-D58 Series
- 22 -
4-4. How to install
<Installation Dimensions and Maintenance Space>
The following installation requirements must be met to install the detector head.
Attach the detector head on the wall and others using four M6 screws.
Tighten the hexagon socket head cap bolt fixing the lid and the main body with a tightening torque of 215.6
±
24.5N
・
cm.
When closing the lid of the detector, make sure that there is no dust on screw, surfaces of the main body
and lid. Then apply grease as specified by RIKEN KEIKI.
220
1000
Unit: mm
Lid turning jig