7 Maintenance
7-2. Regular maintenance mode
- 49 -
RM-6000
7-2. Regular maintenance mode
Mode Item
LCD
display
Details
Maintenance
Mode
(Regular
maintenance)
Gas Introduction
Display
2-0 GAS TEST
Perform the gas introduction test in the regular maintenance
mode.
Zero Adjustment
=> P65
2-1 ZERO
Perform the zero adjustment.
Span Adjustment
=> P66
2-2 SPAN
Perform the span adjustment.
Last Calibrated Date
2-3 LAST CAL
Show the last calibrated date.
Heater Current
Display
2-4 CUR CAL
Show the heater current value.
Environmental Setting
1
=> P53
2-5 SETTING1
Operation setting
SE 0 INHIBIT setting (INHIBIT)
SE 1 Alarm setpoint value setting (ALM P) => P54
SE 2 Alarm delay time setting (ALM DLY)
SE 3 Fault test (F TEST) => P54
Environmental Setting
2
=> P55
2-6 SETTING2
Functions setting
SE 0 RS-485 address setting (ADDRESS)
SE 1 Date/Time setting (DAY TIME) => P58
SE 2 Zero suppression value setting (SUPPRESS)
SE 3 Zero suppression type setting (SUP TYPE)
SE 4 Contact setting for alarm test (TEST RLY)
SE 5 External output setting for alarm test (TEST4-20)
SE 6 Energized/De-energized setting (RLY PTRN) => P59
SE 7 Alarm type setting (ALM TYP)
SE 8 Alarm pattern setting (ALM PTRN)
SE 9 Alarm value limiter setting (AL LIMIT)
SE10 Fault alarm pattern setting (FLT PTRN)
SE11 Zero follower ON/OFF setting (ZERO F)
SE12 External output in maintenance mode setting (MNT OUT)
SE13 External output adjustment (MA 4-20)
Environmental Setting
3
=> P60
2-7 SETTING3
Functions setting
SE 0 Amplifier initialization (AMP DEF)
SE 1 Heater current adjustment (HEAT ADJ)
SE 2 Load voltage adjustment (LOAD ADJ)
SE 3 Measured gas selection (GAS SEL)
SE 4 Peak hold setting (PEAKHOLD)
SE 5 First alarm LCD setting (ALM1 LCD)
SE 6 - - -
SE 7 Double range external output setting (DR OUT)
SE 8 Low flow rate setting (FLOW SET)
SE 9 External output setting (OUT SET)
SE10 RS-485 communication setting (485 PTRN)
SE11 Green LED brightness adjustment (GRN ADJ)
SE12 Red LED brightness adjustment (RED ADJ)
SE13 Orange LED brightness adjustment (ORNG ADJ)
SE14 Buzzer contact switching setting (BZ RLY)
Fault Investigation
2-8 FAULT
Not used.
HART Device
Synchronization
Setting
2-9 HART SYN
Not used.
HART Device Setting
2-10 HART SET
Not used.
WARNING
After the adjustment is completed, never fail to press the MODE key to return to the detection mode.
(If the indicator/alarm unit remains in the regular maintenance mode, it automatically returns to the
detection mode in ten hours.)