background image

22

9. MODES

Note

When operating correctly, the stove may not be overheated. However 

Improper operation can shorten the life expectancy of electrical components 

(blowers, motors and electrical control) and is not allowed!

Pellet operation manual/automatic/comfort

MANUAL MODE

The pellet burner start and stop (ON / OFF button) and set the desired heat 

output (PLUS / MINUS button) can be done on the touch screen directly at the 

HOME main menu.

AUTOMATIC MODE

The exchange between standby and hibernation (ON / OFF button) and set the 

desired heat output (PLUS / MINUS button) can be done on the touch screen 

directly at the HOME main menu.

In AUTO mode, the heating times can be activated and the heating times can 

be programmed.

The pellet burner start is in standby mode (ON) within the heating times (or 

always at deactivated heating times).

The pellet burner stop is outside the heating times.

In the hibernation (OFF) no pellet burner start is possible, the system is turned 

off.

COMFORT MODE

The exchange between standby and hibernation (ON / OFF button) and set the 

desired room temperature (PLUS / MINUS button) can be done on the touch 

screen directly at the HOME main menu.

In the COMFORT mode heating times can be additionally activated.

The pellet burner start is in standby mode (ON) within the heating times (or 

always at deactivated heating times) and if the desired room temperature is 

below the actual room temperature.

The pellet burner stop either outside the heating periods, or if the desired room 

temperature is higher than the actual room temperature.

In the hibernation (OFF) no pellet burner start is possible, the system is turned 

off.

Pellet container refilling

Note

CAUTION when filling! Don’t allow the pellet bag to get in contact with the hot 

stove. Remove immediately pellets which have not found their way into the 

reservoir!

In order to prevent the fire from extinguishingt due to a lack of pellets, we 

recommend to keep an appropriate level in the reservoir upright. A 15 kg bag of 

pellets can be filled into your stove when half of the pellets the pellet container 

was consumed. See the level frequently. The container lid must, however, 

always be kept closed except when filling.

When filling the container during operation (opening the container lid) the fan 

starts up and pellet transport stops immediately, the operation will be resumed 

after closing the container lid (see WARNINGS AND ERROR MESSAGES)

Pellet container capacity (see SPECIFICATIONS).

Emergency operation - heating up without 

electrical Ignition

If the ignition cartridge fail, firelighters can be used for an emergency operation. 

First, start the stove as usual. Wait for the turning of the grid (only for units with 

turning grids). Then open the combustion chamber door and give a handful of 

pellets with the igniter into the cleaned burn pot, light up this and close the 

combustion chamber door.

Note

: Do not use flammable liquids to light up the fire!

Содержание Topo II

Страница 1: ...TOPOII XL Operating Manual...

Страница 2: ...perature shutdown 11 Electrical excess current protection 11 Component monitoring 11 Power failure during heating 11 Power failure during the initial stage 11 5 INSTALLING THE STOVE 12 General informa...

Страница 3: ...TENANCE 25 Basic information 25 Cleaning the fire trough 25 Ampty the ash drawer 25 Cleaning the door glass 25 Cleaning flue pipes 26 Cleaning flue main duct 26 Cleaning the flue blower casing 27 Clea...

Страница 4: ...Spare part overview exploded diagram till serial number 260821...

Страница 5: ...5 EN 4...

Страница 6: ...53 Z34401 Shale top dark 54 Z33958 Soapstone casing right 54 Z34400 Sandstone casing right Art Nr Description 54 Z34415 Shale right white 54 Z34402 Shale right dark 54 B16301 Soapstone casing right ti...

Страница 7: ...on depends on the size of the pellets The larger the pellet the slower the feed and vice versa The owner of small firing systems or the person authorised for the small firing system is to keep the tec...

Страница 8: ...mmable clothing is to be worn when post heating Q Placing non heat resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Stands for drying clothes etc m...

Страница 9: ...ions may be connected to your chimney Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall out of the combustion chamber onto inflammable mate...

Страница 10: ...1 10 arsenic content mg kg 1 1 cadmium content mg kg 1 0 5 mercury content mg kg 1 0 1 lead content mg kg 1 10 nickel content mg kg 1 10 zinc content mg kg 1 100 1 in an anhydrous state 2 diameter mu...

Страница 11: ...ocked manually pressed The stove is ready for operation again after acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If t...

Страница 12: ...e connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air is removed from the living are in the cas...

Страница 13: ...ft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Open the convection cover so far that the cover securing mechanism locks into the designated retaining b...

Страница 14: ...the left side cover You can now lift the left side cover and place it on a soft surface Re assemble the parts in reverse order Dismantling the right side trim Open the container lid Remove the hex sc...

Страница 15: ...tatus returns to active or inactive active depressed inactive Input posibilities OFF Button Pressing the OFF button switches off the section concerned ON Button Pressing the ON button switches on the...

Страница 16: ...ears after successful software update the stove must be disconnected from the mains and the USB stick removed First steps Once the stove has been reconnected to the mains the display changes to the da...

Страница 17: ...following functions HOME status level Stove start stop setting heat output room set temperature current stove status display MODE operating mode level Selection of the required operating mode manual...

Страница 18: ...er is activated is set in this submenu USB update This menu level concerns the software update of the stove Service not accessible to final customers Additional information for the specialist dealer o...

Страница 19: ...s ON OFF 810 Output Th 15 03 2012 15 55 Ignition Grid Motor Air Control Box inc Discharge motor Current speed of screw motor conveying away from the pellet container range 0 1000 Feed motor Current sp...

Страница 20: ...d settings HEATING TIMES This symbol is highlighted if individual heating times are activated ROOM SENSOR This symbol is highlighted if a functioning room sensor is connected FROST PROTECTION This sym...

Страница 21: ...ove has an interface on the rear wall to which you can connect a customary room thermostat This requires a 2 pole cable of 0 5 0 75 mm cross section that you have to connect instead of the cable bridg...

Страница 22: ...mperature is below the actual room temperature The pellet burner stop either outside the heating periods or if the desired room temperature is higher than the actual room temperature In the hibernatio...

Страница 23: ...cur directly customer service is to be notified immediately In the case of error messages that pose a safety risk burnback and flue gas flap is activated and the stove is automatically switched off Wa...

Страница 24: ...EFECT One of the two screw motors for pellet conveying can no longer be actuated Acknowledge error message and restart stove ERROR STL ACTIVATED The STL safety temperature limiter has activated The st...

Страница 25: ...mineral content of the wood remains in the combustion chamber as ash as a residue of the combustion This is an excellent fertiliser for all plants in the garden it is a completely natural product The...

Страница 26: ...ation Re assembly the parts removed in reverse order Cleaning flue main duct The flue main duct should be cleaned at least 2 x a year or after approx 700 kg pellets The flue main duct is located in th...

Страница 27: ...he flue pipe from the flue gas fan and vacuum the flue gas fan housing Re assembly the parts removed in reverse order Cleaning the flame temperature sensor Remove the dust deposits from the sensor at...

Страница 28: ...ompany Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in phase a...

Страница 29: ...hat are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into operation It is v...

Страница 30: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Страница 31: ...urchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts af...

Страница 32: ...Ofentechnik GmbH 4563 Micheldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserv...

Отзывы: