background image

|

25

EN

24

11. CLEANING AND MAINTENANCE

Basic information

Note

Your stove must be switched off and cooled before any maintenance work is 

performed. Ensure that you do not vacuum into the combustion air line during 

heating operation during any cleaning (vacuuming). You could vacuum out 

embers – FIRE RISK!

Note

SERVICE appears in the display after consumption of 700 kg pellets. Cleaning 

and maintenance is to be performed.

This message can be acknowledged by pressing ENTER and operation can 

be continued. The number of SERVICE messages is stored in the background.

Note

Only work on the unit when the mains plug has been disconnected.

The frequency with which the stove requires cleaning and the maintenance 

intervals depend on the fuel you use. High moisture content, ash, dust and chips 

may more than double the maintenance required. We would like to again point 

out that only tested and recommended pellets or logs may be used as fuel.

Tip

wood as fertiliser - The mineral content of the wood remains in the combustion 

chamber as ash as a residue of the combustion. This is an excellent fertiliser 

for all plants in the garden; it is a completely natural product. The ash should 

be stored first and extinguished with water.

Note

Ash may contain embers – only place ash in sheet steel containers.

Cleaning the fire trough

Despite the automatic ash dumping prior to and during heating operation, 

care should be taken that the air intake openings are not blocked with ash or 

clinker. Remove the clinker using the wire brush supplied and vacuum out the 

fire trough.

Note

Clean the fire trough regularly. Only clean when cold, when embers are 

extinguished!

Ampty the ash drawer

Empty the ash drawer regularly. The ash drawer is simply pulled forward with 

the combustion chamber door open

Cleaning the door glass

The viewing window becomes coated in the case of solid fuels, particularly with 

the very fine ash of wood pellets, light or dark depending on the pellet quality 

(especially with low output). The glass can be cleaned best with a moist cloth. 

Stubborn dirt can be removed with a special cleaner available from your stove 

dealer.

Содержание Topo II

Страница 1: ...TOPOII XL Operating Manual...

Страница 2: ...perature shutdown 11 Electrical excess current protection 11 Component monitoring 11 Power failure during heating 11 Power failure during the initial stage 11 5 INSTALLING THE STOVE 12 General informa...

Страница 3: ...TENANCE 25 Basic information 25 Cleaning the fire trough 25 Ampty the ash drawer 25 Cleaning the door glass 25 Cleaning flue pipes 26 Cleaning flue main duct 26 Cleaning the flue blower casing 27 Clea...

Страница 4: ...Spare part overview exploded diagram till serial number 260821...

Страница 5: ...5 EN 4...

Страница 6: ...53 Z34401 Shale top dark 54 Z33958 Soapstone casing right 54 Z34400 Sandstone casing right Art Nr Description 54 Z34415 Shale right white 54 Z34402 Shale right dark 54 B16301 Soapstone casing right ti...

Страница 7: ...on depends on the size of the pellets The larger the pellet the slower the feed and vice versa The owner of small firing systems or the person authorised for the small firing system is to keep the tec...

Страница 8: ...mmable clothing is to be worn when post heating Q Placing non heat resistant objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Stands for drying clothes etc m...

Страница 9: ...ions may be connected to your chimney Q Only use suitable tools from our range of accessories when handling embers and make sure that no embers fall out of the combustion chamber onto inflammable mate...

Страница 10: ...1 10 arsenic content mg kg 1 1 cadmium content mg kg 1 0 5 mercury content mg kg 1 0 1 lead content mg kg 1 10 nickel content mg kg 1 10 zinc content mg kg 1 100 1 in an anhydrous state 2 diameter mu...

Страница 11: ...ocked manually pressed The stove is ready for operation again after acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If t...

Страница 12: ...e connection to the chimney has to be air tight Combustion air Every combustion process requires oxygen from the surrounding air This so called combustion air is removed from the living are in the cas...

Страница 13: ...ft bases to prevent scratches to your living space furniture and stove panels Dismantling stone Open the convection cover so far that the cover securing mechanism locks into the designated retaining b...

Страница 14: ...the left side cover You can now lift the left side cover and place it on a soft surface Re assemble the parts in reverse order Dismantling the right side trim Open the container lid Remove the hex sc...

Страница 15: ...tatus returns to active or inactive active depressed inactive Input posibilities OFF Button Pressing the OFF button switches off the section concerned ON Button Pressing the ON button switches on the...

Страница 16: ...ears after successful software update the stove must be disconnected from the mains and the USB stick removed First steps Once the stove has been reconnected to the mains the display changes to the da...

Страница 17: ...following functions HOME status level Stove start stop setting heat output room set temperature current stove status display MODE operating mode level Selection of the required operating mode manual...

Страница 18: ...er is activated is set in this submenu USB update This menu level concerns the software update of the stove Service not accessible to final customers Additional information for the specialist dealer o...

Страница 19: ...s ON OFF 810 Output Th 15 03 2012 15 55 Ignition Grid Motor Air Control Box inc Discharge motor Current speed of screw motor conveying away from the pellet container range 0 1000 Feed motor Current sp...

Страница 20: ...d settings HEATING TIMES This symbol is highlighted if individual heating times are activated ROOM SENSOR This symbol is highlighted if a functioning room sensor is connected FROST PROTECTION This sym...

Страница 21: ...ove has an interface on the rear wall to which you can connect a customary room thermostat This requires a 2 pole cable of 0 5 0 75 mm cross section that you have to connect instead of the cable bridg...

Страница 22: ...mperature is below the actual room temperature The pellet burner stop either outside the heating periods or if the desired room temperature is higher than the actual room temperature In the hibernatio...

Страница 23: ...cur directly customer service is to be notified immediately In the case of error messages that pose a safety risk burnback and flue gas flap is activated and the stove is automatically switched off Wa...

Страница 24: ...EFECT One of the two screw motors for pellet conveying can no longer be actuated Acknowledge error message and restart stove ERROR STL ACTIVATED The STL safety temperature limiter has activated The st...

Страница 25: ...mineral content of the wood remains in the combustion chamber as ash as a residue of the combustion This is an excellent fertiliser for all plants in the garden it is a completely natural product The...

Страница 26: ...ation Re assembly the parts removed in reverse order Cleaning flue main duct The flue main duct should be cleaned at least 2 x a year or after approx 700 kg pellets The flue main duct is located in th...

Страница 27: ...he flue pipe from the flue gas fan and vacuum the flue gas fan housing Re assembly the parts removed in reverse order Cleaning the flame temperature sensor Remove the dust deposits from the sensor at...

Страница 28: ...ompany Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in phase a...

Страница 29: ...hat are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important points in the putting into operation It is v...

Страница 30: ...tware version Warranty documents Touchdisplay version Door opener Electrical periphery Connection socket earthed GSM modem present Room thermostat present Function checked Check of system components C...

Страница 31: ...urchase Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts af...

Страница 32: ...Ofentechnik GmbH 4563 Micheldorf Austria M llerviertel 20 Telefon 43 7582 686 41 Fax DW 43 E Mail verkauf rika at RIKA AT Technical and design changes as well as typesetting and printing errors reserv...

Отзывы: