![RIKA MultiAir SONO AH Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/rika/multiair-sono-ah/multiair-sono-ah_assembly-instructions-manual_1461306036.webp)
36
Explanations to symbols
...Manually
#8
...Hex #8
#25
...Hexalobular
T25
...Hacksaw
Scope of Delivery E16488
L037
9
7
L037
96
N11228
3
19. SCOPE OF DELIVERY
General information
Q
The convection air amount and temperature is designed for
heating one or, if two fans are installed, two additional rooms.
Q
Note the regional specific fire safety regulations and clarify the
connection situation with the competent authority.
Q
The max. temperature of the convection air is 180° C at the air
outlet.
Q
The convection air duct should be as short as possible.
Q
Keep the number of deflections as small as possible.
Note
Please pay attention to the national and country-specific building
and fire regulations when connecting the convection air pipes.
Installation and assembly must be performed by a trained
specialist only.
Note
Only work on the unit when the mains plug has been disconnected
and the stove has cooled down completely.
Note
During assembly / dismantling do not allow objects (screws etc.) to
fall into the pellet container – they can block the screw conveyor
and damage the stove.
Note
During any conversion work, take particular care of your fingers
and any panels and stove attachments. Select soft bases to
prevent scratches to your living space furniture and stove panels.
B17
527
Содержание MultiAir SONO AH
Страница 1: ...SONO AH SONO RAO Montageanleitung MultiAir...
Страница 2: ......
Страница 12: ...SONO AH SONO RAO Notice de montage MultiAir...
Страница 21: ...SONO AH SONO RAO Istruzioni di montaggio MultiAir 20...
Страница 30: ...SONO AH SONO RAO Assembly instructions MultiAir...
Страница 39: ...SONO AH SONO RAO Montagehandleiding MultiAir 38...