PACKAGING
Your first impression is important to us! - The
packaging for your new fire provides excellent
protection from damage. However damage to the
fire and accessories can occur during transport.
Therefore please check your fire for damage and that
all parts are there on receipt! Report any defects to
your fire dealer immediately!
When unpacking please ensure that the soap stone
panels are intact. The material scratches easily.
Soap stones are not covered by the warranty.
- The packaging for your new fire in the main has no
effect on the environment.
The wood in the packaging has not been surface
treated and can therefore be burned in your fire. The
box and the film (PE) can be recycled without any
problem.
The owner of the small heating system or the
authorised person for the small heating system must
keep the technical documentation in a safe place and
present it to the local authority or the chimney sweep.
TECHNICAL SPECIFICATION
This is a Design 1 fire and has a connection for
fitting to a chimney that is equipped for other fires
and boilers for solid and liquid fuels, insofar as the
chimney dimensions are in accordance with DIN
4705.
The stove is currently undergoing tests. This is a
provisional, theoretical value until the tests are
completed.
Technical Specification
Maße (mm) und Gewichte (kg)
Height:
1000 mm
Width:
480 mm
Depth of the corpus:
448 mm
Weight without casing:
174 kg
Weigth with soap- / sandstone:
222 kg
Weight with steel casing
182 kg
Weight with ceramic casing
196 kg
Weight with Rika thermostone casing
210 kg
Flue pipe outlet diameter:
130 mm
Raed heating capacity as per DIN 18891:
6 kW
Room heating capacity
3 kW
(dependent on the house insulation):
70-160 m
3
Brennstoffdurchsatz
1,6 kg/h
Efficiency
- %
CO
2
-content
- %
CO emission rel. 13% O
- mg/Nm
3
Dust emissions
- mg/Nm
3
Electrical connection
230 V/50Hz
electric input
ca. 4 W
minimum chimney flow
10 Pa
maximum chimney flow
30 Pa
Flue gas values for multiple connection to a chimney
as per DIN 4705, Part 3 or for measuring the chimney
as per DIN 4705, Part 2
Flue gas mass flow
9,6 g/s
Flue gas temperature
224 °C
Minimum flow pressure at rated heating
capacity
10 Pa