4 . O P E R A T I O N W I T H R I K A T R O N I C
HEATING INSTRUCTIONS
Preparation
Insert the mains plug and operate the main switch on the
back of the stove. The main switch illuminates "green".
The indicator on the front of the stove illuminates "green"
for 10 seconds and then changes to "red".
Caution: If the indicator illuminates "orange" or "yellow" for
10 seconds this means an old version of the software is
loaded. The time and temperature details of these
instructions are therefore not identical with the older
version.
Correct heating
1
Open the grate door and on the left and right lay two
small pieces of chipboard longways on the grate floor.
2
On the chipboard lay 3 billets crossways.
3
On the billets
lay more chipboard crossways. Under this chipboard place
a firelighter on the left-hand side (if necessary uncoated
paper can be placed under the chipboard instead of the
firelighter) Open the shaker grate fully and light the
firelighter (or the uncoated paper) and
4
close the grate
doors.
"Correct
lighting"
will
prevent
excessive
development of smoke when lighting.
Fill quantity for lighting ~ 1,2kg
Fill quantity when adding fuel, as required ~ 0,6 – 1,2 kg
As soon as the grate temperature exceeds 50°C, the
indictor changes to "green" (if the indicator does not
change to "green" within 8 minutes of closing the grate
doors, then the heating procedure has failed, i.e. the flame
temperature sensor has not reached 50°C in time).
When the indicator has changed to "green", it takes 20
minutes until the stove starts to regulate the combustion
process. This period is necessary to obtain the required
bed of embers.
Adding fuel
If the indicator changes from "green" to "red – flashing"
then this is the time to add more billets, after adding fuel
for the first time fully close the shaker grate. The "red –
flashing" phase varies according to the respective
environmental influences, as a rule, however, it lasts
approx. 5 – 10 min.
Combustion
If during the "red – flashing" phase no extra fuel is added,
the indicator changes to steady "red". From this point on
no more billets must be added, as ignition of the added
fuel cannot be guaranteed.
1