6. BRIEF INFORMATION ON FUEL - PELLETS

What are pellets?

Wood pellets are a standardised fuel� Every manufacturer must 
adhere to certain conditions in order to enable flawless, energy-
efficient heating� Pellets are made from wooden waste, from sawmills 
and planning workshops, as well as from residue from forestry 
operations� These starting products are crushed, dried, and pressed 
into pellet fuel without any bonding agent�

ENplus – Pellets

This ENplus standard sets benchmarks in the European pellet 
market� The traceability of pellets is ensured thanks to the use of 
identification numbers� The pellet manufacturers’ production 
facilities and manufacturing processes are reviewed every year� 
A quality assurance system ensures the pellets comply with the 
requirements of the new standard and that the conditions for 
trouble-free heating are guaranteed

DE 000

Wood pellet specification according to 
ENplus – A1

Parameter

Measure ENplus-A1

Diameter

mm

6 (

±

1)

2)

Length

mm

3,15–40

3)

Buld density

kg/m3

≥ 600

Calorific value

MJ/kg

≥ 16,5

Water content

Ma.-%

≤ 10

Fine fraction (< 3,15 mm)

Ma.-%

≤ 1

Mechanical rigidity

Ma.-%

≥ 97,5

4)

Ash content

Ma.-%

1)

≤ 0,7

Ash softening temperature

(DT) °C

≥ 1200

Chlorine content

Ma.-% 

1)

≤ 0,02

Sulphur content

Ma.-% 

1)

≤ 0,03

Nitrogen content

Ma.-% 

1)

≤ 0,3

Copper content

mg/kg 

1)

≤ 10

Chrome content

mg/kg 

1)

≤ 10

Arsenic content

mg/kg 

1)

≤ 1

Cadmium content

mg/kg 

1)

≤ 0,5

Mercury content

mg/kg 

1)

≤ 0,1

Lead content

mg/kg 

1)

≤ 10

Nickel content

mg/kg 

1)

≤ 10

Zinc content

mg/kg 

1)

≤ 100

1) in an anhydrous state
2) diameter must be specified
3) a maximum of 1 % of the pellets may be longer than 40 mm,
max� length is 45 mm
4) the limit value of ≥ 97,7 Ma�-% applies when conducting 
measurements with a lignotester (internal control)

Your pellet stove is only approved for the burning of pellets of tested 
quality� Please ask your pellet stove dealer for tested fuel and a list of 
monitored fuel manufacturers�

Note

Only burn pellets that have been inspected according to 
ENplus - A1� Using poor quality or prohibited pellet fuel will have a 
negative effect on the function of your pellet stove and can also 
lead to the warranty becoming null and void, as well as the product 
liability connected with this�

Note

Burning straw, maize, woodchips etc� is not permitted! Observe 
waste incineration legislation! Non-observance of these 
regulations makes void all warranty and guarantee claims and 
may impair the safety of the unit!

Pellet container refilling during operation

Note

CAUTION when filling! Avoid direct contact between the plastic 
bag and the hot stove� Immediately remove all pellets that have 
fallen on the hot stove or next to the container!

We recommend always having a suitable amount of pellets in the 
container to prevent the fire from extinguishing due to a lack of fuel� 
Check the level frequently� However the container lid should be kept 
closed, except during filling�

If you refill the container during operation (open the container lid), 
the fan will speed up and the pellet auger will stop; operation will only 
be continued once the container lid is closed again�

Pellet container capacity: (see TECHNICAL DATA)

Pellet storage

In order to guarantee problem free burning of the wooden pellets, it 
is imperative necessary to store the fuel as dry as possible and free 
from impurities�

Pellets should not be kept in sacks outdoors or stored in a manner 
where they are exposed to the environment� This can lead to 
blockages in the screw conveyor�

Note

Screw stoppers are excluded from the warranty�

Содержание CONNECT PELLET F22

Страница 1: ...CONNECT PELLET F22 F38 Operating manual...

Страница 2: ...es 16 Prior to set up 17 The correct chimney connection 17 Convection air conduction 17 6 BRIEF INFORMATION ON FUEL PELLETS 18 What are pellets 18 Wood pellet specification according to ENplus A1 18 P...

Страница 3: ...the ash drawer 25 Cleaning the door glass 25 Cleaning painted surfaces 25 11 CLEANING 26 Cleaning the convection air openings 26 Combustion air intake 26 Cleaning the pellet container 26 Cleaning the...

Страница 4: ...uction systems can interfere with the combustion air supply The flue gas values of the appliance must be observed for the chimney dimensioning Auxiliary electricity consumption At nominal heat output...

Страница 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Страница 6: ...92 88 89 92 81 79 90 106 111 110 100 105 113 112 109 110 103 104 107 108 102 101 1 19 11 17 11 11 18 18 15 14 16 26 28 29 30 30 34 33 27 22 23 21 20 25 24 20 31 32 35 37 36 32 39 38 30 30 22 23 21 20...

Страница 7: ...20 140 136 127 127 127 139 126 135 138 141 135 142 142 154 153 153 127 127 148 147 150 150 145 148 147 146 145 148 147 152 151 149 149 149 137 133 134 134 125 124 124 175 172 170 170 169 169 174 173 1...

Страница 8: ...226 225 224 223 226 225 230 229 222 222 222 208 208 205 231 207 212 220 233 232 207 207 193 193 196 195 195 192 190 198 199 209 191 194 207 207 207 211 206 197 195 213 252 249 248 248 247 247 251 250...

Страница 9: ...8 271 297 296 300 299 303 304 305 302 302 301 301 312 308 309 310 311 316 313 314 314 315 307 306 260 262 261 267 266 265 263 264 268 286 283 293 291 292 280 291 282 271 281 282 271 279 290 289 284 28...

Страница 10: ...MULTIAIR Flue pipe connection top RAO 320 325 323 322 321 323 322 324 333 332 330 331 335 334...

Страница 11: ...plate left 55 Z38170 Firebrick lining front 56 Z38370 Firebrick lining cover 57 Z38168 Firebrick lining cover right 58 Z38169 Firebrick lining rear 59 Z38172 Baffle plate right 60 Z38134 Cast rear pa...

Страница 12: ...seal Nr Art Nr Description 192 LB00965 Container lid F38 B19220 Container lid assy F38 193 L04058 Rear wall right F22 F38 194 LB00933 Cover display case F38 195 N112142 Flange nut 196 L03975 Small pl...

Страница 13: ...y 284 N112378 Hexagon socket screw 285 N112487 Washer 286 L02643 Motor plate 287 Z18105 Hose 289 N106472 Self tapping screw M05x10 290 L03902 Mount 291 N111806 Hexagonal screw 292 N101570 Hexagonal sc...

Страница 14: ...ith RIKA design outlet values may differ in practice The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firi...

Страница 15: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 16: ...nt objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your s...

Страница 17: ...is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may occur if the chimney is miscalculated and dimensioned wr...

Страница 18: ...ucting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list o...

Страница 19: ...ng the operational safety The status indicator CLEAN appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic big cleaning cycle is perform...

Страница 20: ...8 ASSEMBLY RIKA MULTIAIR Scope of Delivery E15633 B17527 Convection fan complete 3x N112040 Duo Taptite L02724 Motor cover...

Страница 21: ...Only work on the unit when the mains plug has been disconnected and the stove has cooled down completely Note During assembly dismantling do not allow objects screws etc to fall into the pellet conta...

Страница 22: ...hexagonal screws on the rear panel The rear panel tilts backwards Disconnect the earthing cable You can then lift it upwards Run the MULTIAIR fan cable vertically downwards and then further along the...

Страница 23: ...a motor cover and without air duct is not allowed for security reasons Disregard voids your warranty and no liability is accepted for damage Function test and settings Connect the power cord back in a...

Страница 24: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Страница 25: ...the grid vertical Remove the clinker using the brush supplied and sweep the ashes with a broom in the ash tray Vacuum out the fire trough Do not damage the ignition when cleaning with the brush Vacuu...

Страница 26: ...dour Note To prevent your stove from overheating of the internal components do never cover the convection fins Combustion air intake Note Only when the stove is cold You could vacuum out embers FIRE R...

Страница 27: ...screw the two wing screws under the ash door and remove the outer cleaning lid Vacuum the combustion residues off the flue gas collecting duct especially the areas to the side flues Unscrew the 2 wing...

Страница 28: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Страница 29: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Страница 30: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Страница 31: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Страница 32: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Страница 33: ...EN 33 32...

Страница 34: ......

Страница 35: ...EN 35 34...

Страница 36: ...valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z39059_CONNECT_PELLET_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M lle...

Отзывы: