background image

EN

|25

24

10. MAINTENANCE

The frequency with which the stove requires cleaning and the 
maintenance intervals depend on the fuel you use� High moisture 
content, ash, dust and chips may more than double the maintenance 
required� We would like to again point out that only tested and 
recommended pellets or  dry logs may be used as fuel�

Note

Ash may contain embers – only place ash in sheet steel containers� 
FIRE RISK! In a cold state, dispose it of in the household waste�

Note

We recommend at least once a year to have all maintenance 
carried out by your RIKA dealer�

Open the combustion chamber door

To open or close the combustion chamber door and the door of the 
ash-chamber use the included key� This key can be stored on the 
front behind the lower decorative door�

Cleaning the fire trough

(If necessary, but at least 1x a week)

Despite the automatic ash dumping prior to and during heating 
operation you have to remove ash or clinker from the combustion 
chamber, from the fire trough and the turning grid regularly�

Use the cleaning function to put the grid vertical�

Remove the clinker using the brush supplied and sweep the ashes 
with a broom in the ash tray� Vacuum out the fire trough�

Do not damage the ignition when cleaning with the brush� Vacuum 
out the pipe of ignition�

Note

Clean the fire trough regularly� Only clean when cold, when embers 
are extinguished!

Cleaning the flame temperature sensor

Remove the dust deposits from the sensor at regular intervals� Use a 
clean cleaning cloth or newspaper�

Empty the ash drawer

Open the ash-chamber door with the included key and empty the 
ash drawer regularly� The ash drawer is simply pulled forward�

Cleaning the door glass

(If necessary)

The viewing window becomes coated in the case of solid fuels, 
particularly with the very fine ash of wood pellets, light or dark 
depending on the pellet quality (especially with low output)� This is a 
natural process and does not constitute a defect� The glass can be 
cleaned best with a moist cloth� Stubborn dirt can be removed with 
a special cleaner available from your stove dealer� Usual cleaners 
containing acid or solvents can be too harsh and damage the glass�

Cleaning painted surfaces

(If necessary)

Wipe of the painted surfaces with a damp cloth, do not scrub� Do not 
use solvent-containing cleaners�

Содержание CONNECT PELLET F22

Страница 1: ...CONNECT PELLET F22 F38 Operating manual...

Страница 2: ...es 16 Prior to set up 17 The correct chimney connection 17 Convection air conduction 17 6 BRIEF INFORMATION ON FUEL PELLETS 18 What are pellets 18 Wood pellet specification according to ENplus A1 18 P...

Страница 3: ...the ash drawer 25 Cleaning the door glass 25 Cleaning painted surfaces 25 11 CLEANING 26 Cleaning the convection air openings 26 Combustion air intake 26 Cleaning the pellet container 26 Cleaning the...

Страница 4: ...uction systems can interfere with the combustion air supply The flue gas values of the appliance must be observed for the chimney dimensioning Auxiliary electricity consumption At nominal heat output...

Страница 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Страница 6: ...92 88 89 92 81 79 90 106 111 110 100 105 113 112 109 110 103 104 107 108 102 101 1 19 11 17 11 11 18 18 15 14 16 26 28 29 30 30 34 33 27 22 23 21 20 25 24 20 31 32 35 37 36 32 39 38 30 30 22 23 21 20...

Страница 7: ...20 140 136 127 127 127 139 126 135 138 141 135 142 142 154 153 153 127 127 148 147 150 150 145 148 147 146 145 148 147 152 151 149 149 149 137 133 134 134 125 124 124 175 172 170 170 169 169 174 173 1...

Страница 8: ...226 225 224 223 226 225 230 229 222 222 222 208 208 205 231 207 212 220 233 232 207 207 193 193 196 195 195 192 190 198 199 209 191 194 207 207 207 211 206 197 195 213 252 249 248 248 247 247 251 250...

Страница 9: ...8 271 297 296 300 299 303 304 305 302 302 301 301 312 308 309 310 311 316 313 314 314 315 307 306 260 262 261 267 266 265 263 264 268 286 283 293 291 292 280 291 282 271 281 282 271 279 290 289 284 28...

Страница 10: ...MULTIAIR Flue pipe connection top RAO 320 325 323 322 321 323 322 324 333 332 330 331 335 334...

Страница 11: ...plate left 55 Z38170 Firebrick lining front 56 Z38370 Firebrick lining cover 57 Z38168 Firebrick lining cover right 58 Z38169 Firebrick lining rear 59 Z38172 Baffle plate right 60 Z38134 Cast rear pa...

Страница 12: ...seal Nr Art Nr Description 192 LB00965 Container lid F38 B19220 Container lid assy F38 193 L04058 Rear wall right F22 F38 194 LB00933 Cover display case F38 195 N112142 Flange nut 196 L03975 Small pl...

Страница 13: ...y 284 N112378 Hexagon socket screw 285 N112487 Washer 286 L02643 Motor plate 287 Z18105 Hose 289 N106472 Self tapping screw M05x10 290 L03902 Mount 291 N111806 Hexagonal screw 292 N101570 Hexagonal sc...

Страница 14: ...ith RIKA design outlet values may differ in practice The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firi...

Страница 15: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 16: ...nt objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your s...

Страница 17: ...is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may occur if the chimney is miscalculated and dimensioned wr...

Страница 18: ...ucting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list o...

Страница 19: ...ng the operational safety The status indicator CLEAN appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic big cleaning cycle is perform...

Страница 20: ...8 ASSEMBLY RIKA MULTIAIR Scope of Delivery E15633 B17527 Convection fan complete 3x N112040 Duo Taptite L02724 Motor cover...

Страница 21: ...Only work on the unit when the mains plug has been disconnected and the stove has cooled down completely Note During assembly dismantling do not allow objects screws etc to fall into the pellet conta...

Страница 22: ...hexagonal screws on the rear panel The rear panel tilts backwards Disconnect the earthing cable You can then lift it upwards Run the MULTIAIR fan cable vertically downwards and then further along the...

Страница 23: ...a motor cover and without air duct is not allowed for security reasons Disregard voids your warranty and no liability is accepted for damage Function test and settings Connect the power cord back in a...

Страница 24: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Страница 25: ...the grid vertical Remove the clinker using the brush supplied and sweep the ashes with a broom in the ash tray Vacuum out the fire trough Do not damage the ignition when cleaning with the brush Vacuu...

Страница 26: ...dour Note To prevent your stove from overheating of the internal components do never cover the convection fins Combustion air intake Note Only when the stove is cold You could vacuum out embers FIRE R...

Страница 27: ...screw the two wing screws under the ash door and remove the outer cleaning lid Vacuum the combustion residues off the flue gas collecting duct especially the areas to the side flues Unscrew the 2 wing...

Страница 28: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Страница 29: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Страница 30: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Страница 31: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Страница 32: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Страница 33: ...EN 33 32...

Страница 34: ......

Страница 35: ...EN 35 34...

Страница 36: ...valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z39059_CONNECT_PELLET_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M lle...

Отзывы: