background image

32

16. DISPOSAL INFORMATION

RIKA Innovative Ofentechnik GmbH is ensuring that its products 
are eco-friendly throughout the product life cycle� This is why our 
commitment for electronic products goes beyond the end of their 
product life cycle�

Note

For proper disposal of the device, we recommend contacting a 
local waste disposal company�

Note

Please contact your RIKA specialist dealer for professional 
disassembly/dismantling of the device�

Note

We recommend that you remove the parts that come into contact 
with the fire, such as glass, fire trough, grates, draught plates, baffle 
plates, combustion chamber linings (e�g� fireclay), ceramics, ignition 
elements, sensors, combustion chamber sensors and temperature 
monitors and dispose of them in the household waste�

Information on the individual components 
of the device

 

Q

Electrical or electronic components:

 Remove the electrical or 

electronic components from the device by disassembling them� 
These components must not be disposed of in the residual waste� 
Proper disposal should be carried out via the waste electrical 
equipment take-back system� 

 

Q

Fireclay in the combustion chamber:

 Remove fireclay components 

that have been installed in the combustion chamber from the 
appliance� If present, fastening elements must be removed 
beforehand� Fireclay components that come into contact with 
the fire or flue gas must be disposed of; reuse or recycling is not 
possible�

 

Q

Vermiculite in the combustion chamber:

 Remove vermiculite 

that has been installed in the combustion chamber from the 
appliance� If present, fastening elements must be removed 
beforehand� Vermiculite in contact with fire or flue gas must be 
disposed of, reuse or recycling is not possible�

 

Q

Glass ceramic pane:

 Remove the glass ceramic pane using a 

suitable tool� Remove the seals and separate them from the frame 
if present� Transparent glass ceramic can generally be recycled, 
but must be separated into decorated and non-decorated panes� 
The glass ceramic pane can be disposed of as construction waste�

 

Q

Sheet steel:

 Disassemble the sheet steel components of the 

device by unscrewing or flexing (alternatively by mechanical 
crushing)� If present, remove the seals beforehand� Dispose of the 
sheet steel parts as metal scrap�

 

Q

Cast iron:

 Disassemble the components of the cast iron device 

by unscrewing or flexing (alternatively by mechanical crushing)� 
If present, remove gaskets beforehand� Dispose of the cast parts 
as metal scrap�

 

Q

Natural stone:

 Remove existing natural stone mechanically from 

the unit and dispose of as construction waste�

 

Q

Gaskets (glass fibre):

 Remove the gaskets mechanically from the 

device� These components must not be disposed of with residual 
waste, as waste glass fibre cannot be destroyed by incineration� 
Dispose of gaskets as glass and ceramic fibres (artificial mineral 
fibres)�

 

Q

Metal handles and decorative elements:

 If present, remove or 

dismantle metal handles and decorative elements and dispose 
of them as metal scrap�

Note

Please observe the local disposal possibilities for all components�

Extract from the waste code of the 
European Waste List Regulation

Waste code

Waste type

15 01 03

Wooden packaging

17 01 03

Tiles and ceramics

17 02 02

Glass

17 04 05

Iron and steel

17 05 04

Soil and stones

Electronic Waste

In accordance with the European Directive (2012/19/EU) Waste 
Electrical and Electronic Equipment (WEEE) and other local 
regulations, RIKA supports the setup of take-back systems and 
recycling infrastructures� 

Old devices can easily be returned to the municipal waste collectors 
for recycling purposes� Please observe the national regulations to 
that end�

The device may not be disposed of in the normal household waste� 

Содержание CONNECT PELLET F22

Страница 1: ...CONNECT PELLET F22 F38 Operating manual...

Страница 2: ...es 16 Prior to set up 17 The correct chimney connection 17 Convection air conduction 17 6 BRIEF INFORMATION ON FUEL PELLETS 18 What are pellets 18 Wood pellet specification according to ENplus A1 18 P...

Страница 3: ...the ash drawer 25 Cleaning the door glass 25 Cleaning painted surfaces 25 11 CLEANING 26 Cleaning the convection air openings 26 Combustion air intake 26 Cleaning the pellet container 26 Cleaning the...

Страница 4: ...uction systems can interfere with the combustion air supply The flue gas values of the appliance must be observed for the chimney dimensioning Auxiliary electricity consumption At nominal heat output...

Страница 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Страница 6: ...92 88 89 92 81 79 90 106 111 110 100 105 113 112 109 110 103 104 107 108 102 101 1 19 11 17 11 11 18 18 15 14 16 26 28 29 30 30 34 33 27 22 23 21 20 25 24 20 31 32 35 37 36 32 39 38 30 30 22 23 21 20...

Страница 7: ...20 140 136 127 127 127 139 126 135 138 141 135 142 142 154 153 153 127 127 148 147 150 150 145 148 147 146 145 148 147 152 151 149 149 149 137 133 134 134 125 124 124 175 172 170 170 169 169 174 173 1...

Страница 8: ...226 225 224 223 226 225 230 229 222 222 222 208 208 205 231 207 212 220 233 232 207 207 193 193 196 195 195 192 190 198 199 209 191 194 207 207 207 211 206 197 195 213 252 249 248 248 247 247 251 250...

Страница 9: ...8 271 297 296 300 299 303 304 305 302 302 301 301 312 308 309 310 311 316 313 314 314 315 307 306 260 262 261 267 266 265 263 264 268 286 283 293 291 292 280 291 282 271 281 282 271 279 290 289 284 28...

Страница 10: ...MULTIAIR Flue pipe connection top RAO 320 325 323 322 321 323 322 324 333 332 330 331 335 334...

Страница 11: ...plate left 55 Z38170 Firebrick lining front 56 Z38370 Firebrick lining cover 57 Z38168 Firebrick lining cover right 58 Z38169 Firebrick lining rear 59 Z38172 Baffle plate right 60 Z38134 Cast rear pa...

Страница 12: ...seal Nr Art Nr Description 192 LB00965 Container lid F38 B19220 Container lid assy F38 193 L04058 Rear wall right F22 F38 194 LB00933 Cover display case F38 195 N112142 Flange nut 196 L03975 Small pl...

Страница 13: ...y 284 N112378 Hexagon socket screw 285 N112487 Washer 286 L02643 Motor plate 287 Z18105 Hose 289 N106472 Self tapping screw M05x10 290 L03902 Mount 291 N111806 Hexagonal screw 292 N101570 Hexagonal sc...

Страница 14: ...ith RIKA design outlet values may differ in practice The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firi...

Страница 15: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 16: ...nt objects on the stove or near it is prohibited Q Do not place clothing on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your s...

Страница 17: ...is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may occur if the chimney is miscalculated and dimensioned wr...

Страница 18: ...ucting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a list o...

Страница 19: ...ng the operational safety The status indicator CLEAN appears on the display Only for stoves with turning grids Every 6 hours interval adjustable an additionally automatic big cleaning cycle is perform...

Страница 20: ...8 ASSEMBLY RIKA MULTIAIR Scope of Delivery E15633 B17527 Convection fan complete 3x N112040 Duo Taptite L02724 Motor cover...

Страница 21: ...Only work on the unit when the mains plug has been disconnected and the stove has cooled down completely Note During assembly dismantling do not allow objects screws etc to fall into the pellet conta...

Страница 22: ...hexagonal screws on the rear panel The rear panel tilts backwards Disconnect the earthing cable You can then lift it upwards Run the MULTIAIR fan cable vertically downwards and then further along the...

Страница 23: ...a motor cover and without air duct is not allowed for security reasons Disregard voids your warranty and no liability is accepted for damage Function test and settings Connect the power cord back in a...

Страница 24: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Страница 25: ...the grid vertical Remove the clinker using the brush supplied and sweep the ashes with a broom in the ash tray Vacuum out the fire trough Do not damage the ignition when cleaning with the brush Vacuu...

Страница 26: ...dour Note To prevent your stove from overheating of the internal components do never cover the convection fins Combustion air intake Note Only when the stove is cold You could vacuum out embers FIRE R...

Страница 27: ...screw the two wing screws under the ash door and remove the outer cleaning lid Vacuum the combustion residues off the flue gas collecting duct especially the areas to the side flues Unscrew the 2 wing...

Страница 28: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Страница 29: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Страница 30: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Страница 31: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Страница 32: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Страница 33: ...EN 33 32...

Страница 34: ......

Страница 35: ...EN 35 34...

Страница 36: ...valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z39059_CONNECT_PELLET_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M lle...

Отзывы: