RIGOL
Command Systems
Programming Guide for DS1000E, DS1000D Series
2-54
1.
:CHANnel<n>:BWLimit
Command Format:
:CHANnel<n>:BWLimit
{ON|OFF}
:CHANnel<n>:BWLimit?
Function Explanation:
The commands set and query the On/Off state of bandwidth limit. <n> could be
1 or 2.
Returned Format:
The query returns ON or OFF.
Example:
:CHAN2:BWL OFF Turn off the bandwidth limit to CH2.
:CHAN2:BWL?
The query returns OFF.
2.
:CHANnel<n>:COUPling
Command Format:
:CHANnel<n>:COUPling
{DC|AC|GND}
:CHANnel<n>:COUPling?
Function Explanation:
The commands set and query the coupling mode of channel. DC indicates both
the AC and DC components passed from input signal; AC indicates the blocked
DC components; GND indicates to cut off the input of signal; <n> could be 1 or
2.
Returned Format:
The query returns AC, DC or GND.
Example:
:CHAN2:COUP
DC Enable the coupling mode of channel 2.
:CHAN2:COUP?
The query returns DC.
3.
:CHANnel<n>:DISPlay
Содержание DS1000E Series, DS1000D Series
Страница 1: ...RIGOL Programming Guide DS1000E DS1000D Series Digital Oscilloscope July 2009 RIGOL Technologies Inc ...
Страница 2: ......
Страница 6: ......
Страница 86: ...RIGOL Command Systems Programming Guide for DS1000E DS1000D Series 2 74 LA GROU1 SIZ The query returns SMALL ...
Страница 102: ......
Страница 129: ...Programming Guide for DS1000E DS1000D Series 3 27 After you set the Start event see the result below ...
Страница 132: ......