RIGOL
Chapter 2 Front Panel Operations
2-28
DG1000Z User’s Guide
Cycles
Set the cycles of the inserted waveform. The range is from 1 to 16 and the
default is 1. The each cycle’s points of the inserted waveform is fixed at
1024.
Select Waveform
Select the waveform to be inserted. You can select the basic waveforms
(Sine, Square, Ramp, Pulse and Noise) or the built-in waveforms (160 types
optional, refer to Table 2-2).
Note:
when inserting a waveform, you should first set the insert position, insert
way and cycles, and then select the desired waveform types (because the insert
operation will be executed immediately after the desired waveform is selected).
7.
Edit Points
Sa is used to denote the points currently set. In point edit mode, users can
select the number of the first Sa waveform point and set the voltage for each
point. Press this menu key to enter the “Edit Points” interface.
Edit Points
Select the number (1 to Sa) of the point to be edited and input the desired
value using numeric keyboard or direction keys and knob.
Voltage
Set the voltage of the current point (the units available are mV and V). The
range is limited by the current “High Level” and “Low Level”.
Insert
Insert a point at the point currently edited. The voltage of the inserted point
is the same as the voltage value currently set and the original waveform
data are moved behind the inserted point. At this time, the number of the
points increases by 1.
Note:
In sample rate editing mode, the total number of points of the
waveform currently edited is from 8 to 16384. If the total number of
points is 16384, no waveform point can be inserted.
In period editing mode, if the current total number of points is greater
than 8192, the data after the 8192nd point will be truncated.
Delete
Delete the current point. At this time, the number of the points decreases
by 1.
Move Position
Modify the voltage of the specified point to the voltage of the point
Содержание DG1022Z