User’s Guide for DG1022
2-53
1.
To Set the Output Load
For the [Output] Connector on the Front panel, the Generator has a 50Ω series
output impedance. If the actual load does not match the set one, the amplitude
and offset displayed are incorrect. This function is used to match the displayed
voltage with the expected one.
Steps for setting the load value:
(1)
Press Utility
CH1
Load, enter the following interface.
Figure 2-56
Load Value Setting Interface
Please note that the Load Parameter shown on the right bottom is the default
setting when the power is on or the pre-set load value. If the current value is valid
for the output, then the current value can be used.
(2)
Input the desired Load Value.
Use the Keypad to enter the desired value and choose the unit, Ω or KΩ, press the
corresponding button.
Figure 2-57
Change the Load Value