Example 3: Output a Ramp Waveform
How to generate a Ramp waveform with 10ms Period, 100mV
PP
Amplitude, 20mV
DC
Offset, 80% Symmetry and 60° Phase.
The operation steps:
1.
Set the Period.
(1)
Press Ramp
Freq/Period
Period which will display in reverse color.
(2)
Input “10” from the keypad and choose the unit “ms” to set the Period as 10ms.
2.
Set the Amplitude.
(1)
Press Ampl/ HiLev
Ampl which will display in reverse color.
(2)
Enter “100” from the keypad and choose the unit “mV
PP
” to set the Amplitude as
100mV
PP
.
3.
Set the Offset.
(1)
Press Offset /LoLev
Offset which will display in reverse color.
(2)
Enter “20” from the keypad and choose the unit “mV
DC
” to set the Offset as
20mV
DC
.
4.
Set the Symmetry.
(1)
Press Symm which will display in reverse color.
(2)
Enter “80” from the keypad and choose the unit “%” to set the Symmetry as 80%.
5.
Set the Phase.
(1)
Press Phase which will display in reverse color.
(2)
Enter “60” from the keypad and choose the unit “°” to set the Phase as 60°.
After finishing the above settings, press View, the generated waveform is shown in
Figure 3-3.
Figure 3-3
Ramp Waveform Output