RF096-35/55-100 [Revision 1.0.0] 12.12.2018
Pipe ID Control System. RF096-35/55-100 Series
23
12.2.3. "End character" mode
As soon as the converter detects the end characters of the incoming serial data
stream, it removes the data from the serial receive buffer and transfers it to the PROFINET
IO device output buffer of the converter.
If the time interval between two consecutive bytes is longer than the time needed to
transmit three bytes, then the module treats this situation as an end of a string.
To use this feature, the "End char of input data" parameter must not be set to
"None".
12.3. PROFINET Output Data Area
The maximum output data length of I-7580 is 384 bytes. The first 8 bytes are
needed to set the communication behavior of the converter.
Byte
Data
Description
1
0 255
Data output command.
2
0x01
Control bit – clear all diagnostic messages.
0x02
Control bit – clear Received data count.
0x04
Control bit – clear Transmitted data count.
3
Length
Output data length (High byte).
4
Output data length (Low byte).