11
20138630
GB
Technical description of the burner
4.7
Burner description
1
Combustion head
2
Ignition electrode
3
Flame sensor probe
4
Gas valve
5
Air/gas mixer in the suction line circuit
6
Gas pressure test point
7
Gas valve pipe
8
Gas inlet
9
Boiler fixing flange
10 Fan
11 Air passage in fan
12 Electrical control box
13 Reset button
14 Plug-socket on ionisation probe cable
15 Transformer
16 Plate with 4 holes, useful for passing electric cables
17 Fuses
18 Relay
19 Programming card
20 Switch 0-1
21 Terminal board for electrical wiring
1
2
9
14
12
18
5
11
3
17
19
16
11
21
15
7
8
4
20
10
6
13
20136770
Fig. 3
WARNING
Burner lockout may occur.
CONTROL BOX LOCKOUT:
The lockout signal is indicated on the display of the
control box with “LOC” and the error code. To un-
lock, press the button 13) (Fig. 3).