20059594
6
GB
Technical description of the burner
3.1
Technical data
Tab. A
(1)
Reference conditions: ambient temperature 68 °F (20°C) - Barometric pressure 394” WC - Altitude 329 ft.
(2)
Pressure at test point 7) (Fig. 3 at page 8) with zero pressure in the combustion chamber and maximum burner output.
(3)
Sound pressure measured in manufacturer’s combustion laboratory, with burner operating on test boiler and at maximum rated output.
(4)
Equivalent Btu values based on 1 USGPH = 140,000 Btu/hr.
3.2
Electrical data
3.2.1
Three phase burner
Tab. B
3.3
Burner models designation
Tab. C
3
Technical description of the burner
Model
RLS 28/E
Output
(1)
Delivery
(1)
2
nd
stage
MBtu/hr
(4)
kW
GPH
616 - 1232
181 - 361
4.4 - 8.8
min. 1
st
stage
MBtu/hr
(4)
kW
GPH
378
111
2.7
Fuel
#2 Light oil
Natural gas / Propane gas
Gas pressure at maximum delivery
(2)
Gas: Natural gas
” WC
4.33
Operation
Light oil: low-high-low
Gas: low-high-low or modulating
Nozzles
number
2
Ambient temperature
°F
32 - 104 (0 - 40 °C)
Combustion air temperature
°F max
140 (60 °C)
Noise Levels
(3)
dB(A)
68
Model
RLS 28/E
Control circuit power supply
V/Ph/Hz
120/1/60
Main power supply
V/Ph/Hz
120/1/60
Fan motor
Fan motor capacitor
rpm
HP
V
A
µF
3400
0.5
120
5.2
45
Pump motor
Pump motor capacitor
rpm
HP
V
A
µF
3250
0.12
120
2.2
12.5
Ignition transformer
V1 - V2
I1 - I2
120 V - 2 x 5 kV
2.7 A - 30 mA
Electrical power consumption
W
600
Electrical control circuit cons.
W max
750
Total electrical consumption
W
1350
Electrical protection
NEMA 1
Model
Code
Code RBNA
Voltage
Flame safeguard
RLS 28/E
20059556
tbd
120/1/60
Burner mounted
Содержание RLS 28/E